The UPS input voltage is less than or equal to the value of the upsConfigInputVoltageLow MIB variable.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)CircitorMIBdepot
OID reference
1.3.6.1.4.1.850.0.15
The UPS input voltage is less than or equal to the value of the upsConfigInputVoltageLow MIB variable.
Identification
{1 3 6 1 4 1 850 0 15}
Available source records contain 2 distinct definitions; some records may not include a definition.
utilityVoltageLow TRAP-TYPE
ENTERPRISE tripplite
DESCRIPTION
"The UPS input voltage is less than or equal to the value of
the upsConfigInputVoltageLow MIB variable."
::= 15utilityVoltageLow TRAP-TYPE
ENTERPRISE tripplite
DESCRIPTION
"The UPS input voltage is less than or equal to the value of
the upsConfigInputVoltageLow MIB variable."
::= 15
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The UPS input voltage is less than or equal to the value of the upsConfigInputVoltageLow MIB variable.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)CircitorMIBdepot
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: unspecified.
Names: utilityVoltageLow
{
"smi_kind": "TRAP-TYPE",
"definition": [
"utilityVoltageLow",
"TRAP-TYPE",
"ENTERPRISE",
"tripplite",
"DESCRIPTION",
"\"The UPS input voltage is less than or equal to the value of the upsConfigInputVoltageLow MIB variable.\"",
"::=",
"15"
],
"syntax_tree": [
[
"objectIdentifier",
[
"tripplite"
]
],
[],
[
"DESCRIPTION",
"The UPS input voltage is less than or equal to the value of the upsConfigInputVoltageLow MIB variable."
],
null
]
}Vendor MIB copy from the Observium Community archive.
Module: TRIPPUPS1-MIB
{'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'OBJECT-TYPE', 'NetworkAddress', 'IpAddress', 'Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString']}Module: TRIPPUPS1-MIB
See published definition above
{'RFC1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'OBJECT-TYPE', 'NetworkAddress', 'IpAddress', 'Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.850.0.5 | upsOnBattery | 0 | 0 | |
| 1.3.6.1.4.1.850.0.6 | powerRestored | 0 | 0 | |
| 1.3.6.1.4.1.850.0.7 | lowBattery | 0 | 0 | |
| 1.3.6.1.4.1.850.0.8 | returnFromLowBattery | 0 | 0 | |
| 1.3.6.1.4.1.850.0.9 | communicationEstablished | 0 | 0 | |
| 1.3.6.1.4.1.850.0.10 | communicationLost | 0 | 0 | |
| 1.3.6.1.4.1.850.0.11 | upsOverload | 0 | 0 | |
| 1.3.6.1.4.1.850.0.12 | upsDiagnosticsFailed | 0 | 0 | |
| 1.3.6.1.4.1.850.0.13 | upsDiagnosticsPassed | 0 | 0 | |
| 1.3.6.1.4.1.850.0.14 | utilityVoltageHigh | 0 | 0 | |
| 1.3.6.1.4.1.850.0.16 | utilityVoltageReturnToNormal | 0 | 0 | |
| 1.3.6.1.4.1.850.0.17 | batteryTemperatureHigh | 0 | 0 | |
| 1.3.6.1.4.1.850.0.18 | shutdownPending | 0 | 0 | |
| 1.3.6.1.4.1.850.0.19 | upsSleeping | 0 | 0 | |
| 1.3.6.1.4.1.850.0.20 | upsWokeup | 0 | 0 | |
| 1.3.6.1.4.1.850.0.21 | upsBatteryNeedsReplacement | 0 | 0 |