Status in source: current.
Names: turboChainConfigInterface
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"turboChainConfigInterface",
"OBJECT-TYPE",
"SYNTAX",
"OCTET",
"STRING",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The value configures two Turbo Chain ports at the same time. The first octet string is the Turbo Chain primary interface. The second octet string is the Turbo Chain secondary interface. If Turbo Chain role of this switch is Turbo Chain Head, primary interface is Head port. If Turbo Chain role of this switch is Turbo Chain Tail, primary interface is Tail port. For example, if users want to configure ifIndex 19 as the Turbo Chain head port, and ifIndex 20 as the Turbo Chain member port. The octet string shall be 0x13 0x14.\"",
"::=",
"{",
"turboChainConfiguration",
"3",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"OCTET STRING"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value configures two Turbo Chain ports at the same time. The first octet string is the Turbo Chain primary interface. The second octet string is the Turbo Chain secondary interface. If Turbo Chain role of this switch is Turbo Chain Head, primary interface is Head port. If Turbo Chain role of this switch is Turbo Chain Tail, primary interface is Tail port. For example, if users want to configure ifIndex 19 as the Turbo Chain head port, and ifIndex 20 as the Turbo Chain member port. The octet string shall be 0x13 0x14."
],
null,