Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"equipmentNodeIcnRedundancyMode",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"disabled",
"(",
"1",
")",
",",
"ring",
"(",
"3",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Indicates whether the internal communication network between sub-racks, ICN3 and ICN4, can be connected in a redundant manner or not. disabled - Non-redundant ICN connection. Both ICN ports are enable for forwarding. Note: Connecting both ICN ports to the same internal switch will cause a loop. ring - Redundant ICN connection. Only one ICN port at a time is enabled for forwarding even if both are physically connected and both links are up. Note: The port that is first connected will be used for forwarding and if disconnected, the other port will be enabled automatically. disabled - Non-redundant connection. ring - Redundantly connected in a ring. \"",
"DEFVAL",
"{",
"ring",
"}",
"::=",
"{",
"equipmentNode",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"disabled",
1
],
[
"ring",
3
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Indicates whether the internal communication network between sub-racks, ICN3 and ICN4, can be connected in a redundant manner or not. disabled - Non-redundant ICN connection. Both ICN ports are enable for forwarding. Note: Connecting both ICN ports to the same internal switch will cause a loop. ring - Redundant ICN connection. Only one ICN port at a time is enabled for forwarding even if both are physically connected and both links are up. Note: The port that is first connected will be used for forwarding and if disconnected, the other port will be enabled automatically. disabled - Non-redundant connection. ring - Redundantly connected in a ring."
],
null,
null,
null,
[
"DEFVAL",
"ring"
]
]
}