Loss of frame. Applicable for SDH/Sonet signal formats. A: SDH frame can not be located. D: SDH frame is located.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.8708.2.12.2.2.1.1.27
Loss of frame. Applicable for SDH/Sonet signal formats. A: SDH frame can not be located. D: SDH frame is located.
Identification
{1 3 6 1 4 1 8708 2 12 2 2 1 1 27}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
mrtIfLossOfFrame OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loss of frame.
Applicable for SDH/Sonet signal formats.
A: SDH frame can not be located.
D: SDH frame is located.
"
::= { mrtIfEntry 27 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Loss of frame. Applicable for SDH/Sonet signal formats. A: SDH frame can not be located. D: SDH frame is located.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: mrtIfLossOfFrame
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"mrtIfLossOfFrame",
"OBJECT-TYPE",
"SYNTAX",
"FaultStatus",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Loss of frame. Applicable for SDH/Sonet signal formats. A: SDH frame can not be located. D: SDH frame is located. \"",
"::=",
"{",
"mrtIfEntry",
"27",
"}"
],
"syntax_tree": [
[
"row",
"FaultStatus"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Loss of frame. Applicable for SDH/Sonet signal formats. A: SDH frame can not be located. D: SDH frame is located."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: LUM-MULTIRATE-MIB
See published definition above
{'LUM-TC': ['FaultStatus', 'MgmtNameString', 'SubrackNumber', 'SlotNumber', 'PortNumber', 'BoardOrInterfaceOperStatus', 'BoardOrInterfaceAdminStatus', 'CommandString', 'LambdaFrequency', 'SignalFormat', 'TrxMedia', 'ObjectProperty'], 'LUM-REG': ['lumModules', 'lumMultirateMIB'], 'SNMPv2-TC': ['TestAndIncr', 'DisplayString', 'DateAndTime'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'NOTIFICATION-TYPE', 'Gauge32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE', 'NOTIFICATION-GROUP']}Related source files and packages:
Registration