ocmIfControlMode

1.3.6.1.4.1.8708.2.33.2.2.1.1.18

Description

What mode the ocm is in. normal - the switch toggle every hour and measure both ports. commissioning - the switch is set to one active port and measurement is made continuously on this port. After 15 minutes it will change back to normal mode. Note that it is not possible to get updated values on port that is not chos…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.8708.2.33.2.2.1.1 (ocmIfEntry)
Node code
18
Node name
ocmIfControlMode
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.8708.2.33.2.2.1.1.18
URN notation
urn:oid:1.3.6.1.4.1.8708.2.33.2.2.1.1.18
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 8708 2 33 2 2 1 1 18}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) lumentis(8708) lumGeneric(2) lumOcmMIB(33) lumOcmMIBObjects(2) ocmIfList(2) ocmIfTable(1) ocmIfEntry(1) ocmIfControlMode(18)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) lumentis(8708) lumGeneric(2) lumOcmMIB(33) lumOcmMIBObjects(2) ocmIfList(2) ocmIfTable(1) ocmIfEntry(1) ocmIfControlMode(18)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) lumentis(8708) lumGeneric(2) lumOcmMIB(33) lumOcmMIBObjects(2) ocmIfList(2) ocmIfTable(1) ocmIfEntry(1) ocmIfControlMode(18)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) lumentis(8708) lumGeneric(2) lumOcmMIB(33) lumOcmMIBObjects(2) ocmIfList(2) ocmIfTable(1) ocmIfEntry(1) ocmIfControlMode(18)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) lumentis(8708) lumGeneric(2) lumOcmMIB(33) lumOcmMIBObjects(2) ocmIfList(2) ocmIfTable(1) ocmIfEntry(1) ocmIfControlMode(18)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) lumentis(8708) lumGeneric(2) lumOcmMIB(33) lumOcmMIBObjects(2) ocmIfList(2) ocmIfTable(1) ocmIfEntry(1) ocmIfControlMode(18)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) lumentis(8708) lumGeneric(2) lumOcmMIB(33) lumOcmMIBObjects(2) ocmIfList(2) ocmIfTable(1) ocmIfEntry(1) ocmIfControlMode(18)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) lumentis(8708) lumGeneric(2) lumOcmMIB(33) lumOcmMIBObjects(2) ocmIfList(2) ocmIfTable(1) ocmIfEntry(1) ocmIfControlMode(18)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) lumentis(8708) lumGeneric(2) lumOcmMIB(33) lumOcmMIBObjects(2) ocmIfList(2) ocmIfTable(1) ocmIfEntry(1) ocmIfControlMode(18)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) lumentis(8708) lumGeneric(2) lumOcmMIB(33) lumOcmMIBObjects(2) ocmIfList(2) ocmIfTable(1) ocmIfEntry(1) ocmIfControlMode(18)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) lumentis(8708) lumGeneric(2) lumOcmMIB(33) lumOcmMIBObjects(2) ocmIfList(2) ocmIfTable(1) ocmIfEntry(1) ocmIfControlMode(18)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) lumentis(8708) lumGeneric(2) lumOcmMIB(33) lumOcmMIBObjects(2) ocmIfList(2) ocmIfTable(1) ocmIfEntry(1) ocmIfControlMode(18)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) lumentis(8708) lumGeneric(2) lumOcmMIB(33) lumOcmMIBObjects(2) ocmIfList(2) ocmIfTable(1) ocmIfEntry(1) ocmIfControlMode(18)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) lumentis(8708) lumGeneric(2) lumOcmMIB(33) lumOcmMIBObjects(2) ocmIfList(2) ocmIfTable(1) ocmIfEntry(1) ocmIfControlMode(18)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) lumentis(8708) lumGeneric(2) lumOcmMIB(33) lumOcmMIBObjects(2) ocmIfList(2) ocmIfTable(1) ocmIfEntry(1) ocmIfControlMode(18)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) lumentis(8708) lumGeneric(2) lumOcmMIB(33) lumOcmMIBObjects(2) ocmIfList(2) ocmIfTable(1) ocmIfEntry(1) ocmIfControlMode(18)}
OID-IRI notation
  • /1/3/6/1/4/1/8708/2/33/2/2/1/1/18
  • /ISO/Identified-Organization/6/1/4/1/8708/2/33/2/2/1/1/18
  • /ISO/3/6/1/4/1/8708/2/33/2/2/1/1/18
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/8708/lumGeneric/lumOcmMIB/lumOcmMIBObjects/ocmIfList/ocmIfTable/ocmIfEntry/ocmIfControlMode
  • /iso/identified-organization/dod/internet/private/enterprise/lumentis/lumGeneric/lumOcmMIB/lumOcmMIBObjects/ocmIfList/ocmIfTable/ocmIfEntry/ocmIfControlMode
  • /iso/identified-organization/dod/internet/private/enterprises/8708/lumGeneric/lumOcmMIB/lumOcmMIBObjects/ocmIfList/ocmIfTable/ocmIfEntry/ocmIfControlMode
  • /iso/identified-organization/dod/internet/private/enterprises/lumentis/lumGeneric/lumOcmMIB/lumOcmMIBObjects/ocmIfList/ocmIfTable/ocmIfEntry/ocmIfControlMode
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/8708/lumGeneric/lumOcmMIB/lumOcmMIBObjects/ocmIfList/ocmIfTable/ocmIfEntry/ocmIfControlMode
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/lumentis/lumGeneric/lumOcmMIB/lumOcmMIBObjects/ocmIfList/ocmIfTable/ocmIfEntry/ocmIfControlMode
  • /iso/identified-organization/dod/internet/private/vendor-objects/8708/lumGeneric/lumOcmMIB/lumOcmMIBObjects/ocmIfList/ocmIfTable/ocmIfEntry/ocmIfControlMode
  • /iso/identified-organization/dod/internet/private/vendor-objects/lumentis/lumGeneric/lumOcmMIB/lumOcmMIBObjects/ocmIfList/ocmIfTable/ocmIfEntry/ocmIfControlMode
  • /iso/org/dod/internet/private/enterprise/8708/lumGeneric/lumOcmMIB/lumOcmMIBObjects/ocmIfList/ocmIfTable/ocmIfEntry/ocmIfControlMode
  • /iso/org/dod/internet/private/enterprise/lumentis/lumGeneric/lumOcmMIB/lumOcmMIBObjects/ocmIfList/ocmIfTable/ocmIfEntry/ocmIfControlMode
  • /iso/org/dod/internet/private/enterprises/8708/lumGeneric/lumOcmMIB/lumOcmMIBObjects/ocmIfList/ocmIfTable/ocmIfEntry/ocmIfControlMode
  • /iso/org/dod/internet/private/enterprises/lumentis/lumGeneric/lumOcmMIB/lumOcmMIBObjects/ocmIfList/ocmIfTable/ocmIfEntry/ocmIfControlMode
  • /iso/org/dod/internet/private/ldap-enterprise/8708/lumGeneric/lumOcmMIB/lumOcmMIBObjects/ocmIfList/ocmIfTable/ocmIfEntry/ocmIfControlMode
  • /iso/org/dod/internet/private/ldap-enterprise/lumentis/lumGeneric/lumOcmMIB/lumOcmMIBObjects/ocmIfList/ocmIfTable/ocmIfEntry/ocmIfControlMode
  • /iso/org/dod/internet/private/vendor-objects/8708/lumGeneric/lumOcmMIB/lumOcmMIBObjects/ocmIfList/ocmIfTable/ocmIfEntry/ocmIfControlMode
  • /iso/org/dod/internet/private/vendor-objects/lumentis/lumGeneric/lumOcmMIB/lumOcmMIBObjects/ocmIfList/ocmIfTable/ocmIfEntry/ocmIfControlMode
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current
Default value
normal

Enumerated values

ValueName
1normal
2commissioning

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.

Published row index: ocmIfIndex.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.8708.2.33.2.2.1.1.18

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

ocmIfControlMode OBJECT-TYPE
    SYNTAX      INTEGER {
        normal (1),
        commissioning (2) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "What mode the ocm is in.

        normal - the switch toggle every hour
        and measure both ports.

        commissioning - the switch is set to one active
        port and measurement is made continuously on this port.
        After 15 minutes it will change back to normal mode.
        Note that it is not possible to get updated
        values on port that is not chosen as active during
        commissioning mode.

"
    DEFVAL { normal }
    ::= { ocmIfEntry 18 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

What mode the ocm is in. normal - the switch toggle every hour and measure both ports. commissioning - the switch is set to one active port and measurement is made continuously on this port. After 15 minutes it will change back to normal mode. Note that it is not possible to get updated values on port that is not chosen as active during commissioning mode.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 2 sources

Description 1

ocmIfControlMode · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)2 sources

Status in source: current.

Names: ocmIfControlMode

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ocmIfControlMode",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "normal",
    "(",
    "1",
    ")",
    ",",
    "commissioning",
    "(",
    "2",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"What mode the ocm is in. normal - the switch toggle every hour and measure both ports. commissioning - the switch is set to one active port and measurement is made continuously on this port. After 15 minutes it will change back to normal mode. Note that it is not possible to get updated values on port that is not chosen as active during commissioning mode. \"",
    "DEFVAL",
    "{",
    "normal",
    "}",
    "::=",
    "{",
    "ocmIfEntry",
    "18",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "normal",
            1
          ],
          [
            "commissioning",
            2
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "What mode the ocm is in. normal - the switch toggle every hour and measure both ports. commissioning - the switch is set to one active port and measurement is made continuously on this port. After 15 minutes it will change back to normal mode. Note that it is not possible to get updated values on port that is not chosen as active during commissioning mode."
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      "normal"
    ]
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.8708)

Carlsson Martin

Siblings (34)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.8708.2.33.2.2.1.1.1 ocmIfIndex00
1.3.6.1.4.1.8708.2.33.2.2.1.1.2 ocmIfName00
1.3.6.1.4.1.8708.2.33.2.2.1.1.3 ocmIfDescr00
1.3.6.1.4.1.8708.2.33.2.2.1.1.4 ocmIfSubrack00
1.3.6.1.4.1.8708.2.33.2.2.1.1.5 ocmIfSlot00
1.3.6.1.4.1.8708.2.33.2.2.1.1.6 ocmIfRxPort00
1.3.6.1.4.1.8708.2.33.2.2.1.1.7 ocmIfInvPhysIndexOrZero00
1.3.6.1.4.1.8708.2.33.2.2.1.1.8 ocmIfAdminStatus00
1.3.6.1.4.1.8708.2.33.2.2.1.1.9 ocmIfOperStatus00
1.3.6.1.4.1.8708.2.33.2.2.1.1.12 ocmIfPowerThreshold00
1.3.6.1.4.1.8708.2.33.2.2.1.1.13 ocmIfUpdateLastChangeTime00
1.3.6.1.4.1.8708.2.33.2.2.1.1.14 ocmIfConnectedSubrack00
1.3.6.1.4.1.8708.2.33.2.2.1.1.15 ocmIfConnectedSlot00
1.3.6.1.4.1.8708.2.33.2.2.1.1.16 ocmIfConnectedPort00
1.3.6.1.4.1.8708.2.33.2.2.1.1.17 ocmIfActivePort00
1.3.6.1.4.1.8708.2.33.2.2.1.1.21 ocmIfReferenceTime00
1.3.6.1.4.1.8708.2.33.2.2.1.1.22 ocmIfSwitchFailure00
1.3.6.1.4.1.8708.2.33.2.2.1.1.23 ocmIfDataSourceNotDefined00
1.3.6.1.4.1.8708.2.33.2.2.1.1.24 ocmIfCommissioningMode00
1.3.6.1.4.1.8708.2.33.2.2.1.1.25 ocmIfModuleFailure00
1.3.6.1.4.1.8708.2.33.2.2.1.1.26 ocmIfConfigurationCommand00
1.3.6.1.4.1.8708.2.33.2.2.1.1.27 ocmIfChangeConnectedPort00
1.3.6.1.4.1.8708.2.33.2.2.1.1.28 ocmIfSaveReference00
1.3.6.1.4.1.8708.2.33.2.2.1.1.29 ocmIfPowerOffset00
1.3.6.1.4.1.8708.2.33.2.2.1.1.30 ocmIfConnectedBoardType00
1.3.6.1.4.1.8708.2.33.2.2.1.1.31 ocmIfChangeConnectedBoardType00
1.3.6.1.4.1.8708.2.33.2.2.1.1.32 ocmIfMaxPowerLevel00
1.3.6.1.4.1.8708.2.33.2.2.1.1.33 ocmIfMinPowerLevel00
1.3.6.1.4.1.8708.2.33.2.2.1.1.34 ocmIfDeltaPower00
1.3.6.1.4.1.8708.2.33.2.2.1.1.35 ocmIfChangePowerThreshold00
1.3.6.1.4.1.8708.2.33.2.2.1.1.36 ocmIfChangePowerOffset00
1.3.6.1.4.1.8708.2.33.2.2.1.1.37 ocmIfPowerOffsetAdjustment00
1.3.6.1.4.1.8708.2.33.2.2.1.1.38 ocmIfSpacingMode00
1.3.6.1.4.1.8708.2.33.2.2.1.1.39 ocmIfHighInputPower00