Shows the name of the wdm port and possible subchannel that it is connected to or Unconnected if not connected.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.8708.2.35.2.2.1.1.14
Shows the name of the wdm port and possible subchannel that it is connected to or Unconnected if not connected.
Identification
{1 3 6 1 4 1 8708 2 35 2 2 1 1 14}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
sdhpdhE1t1ConnectionStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shows the name of the wdm port and
possible subchannel that it is connected to
or Unconnected if not connected.
"
DEFVAL { "Not connected" }
::= { sdhpdhE1t1Entry 14 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Shows the name of the wdm port and possible subchannel that it is connected to or Unconnected if not connected.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: sdhpdhE1t1ConnectionStatus
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"sdhpdhE1t1ConnectionStatus",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Shows the name of the wdm port and possible subchannel that it is connected to or Unconnected if not connected. \"",
"DEFVAL",
"{",
[
"literal",
"224e6f7420636f6e6e656374656422"
],
"}",
"::=",
"{",
"sdhpdhE1t1Entry",
"14",
"}"
],
"syntax_tree": [
[
"row",
"DisplayString"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Shows the name of the wdm port and possible subchannel that it is connected to or Unconnected if not connected."
],
null,
null,
null,
[
"DEFVAL",
"\"Not connected\""
]
]
}Vendor MIB copy from the Observium Community archive.
Module: LUM-SDHPDH-MIB
See published definition above
{'LUM-TC': ['FaultStatus', 'MgmtNameString', 'BoardOrInterfaceAdminStatus', 'BoardOrInterfaceOperStatus', 'CommandString'], 'LUM-REG': ['lumModules', 'lumSdhpdhMIB'], 'SNMPv2-TC': ['DisplayString', 'DateAndTime'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE']}Related source files and packages:
Registration