Indicates the priority1 value of the grandmaster clock. The value is useful in BMC algorithm.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.8886.1.26.4.6
Indicates the priority1 value of the grandmaster clock. The value is useful in BMC algorithm.
Identification
{1 3 6 1 4 1 8886 1 26 4 6}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.8886.1.26.4.6.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
raisecomPtpGrandmasterPriority1 OBJECT-TYPE
SYNTAX Integer32(0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the priority1 value of the grandmaster clock.
The value is useful in BMC algorithm."
::= { raisecomPtpParent 6 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Indicates the priority1 value of the grandmaster clock. The value is useful in BMC algorithm.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: raisecomPtpGrandmasterPriority1
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"raisecomPtpGrandmasterPriority1",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"255",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Indicates the priority1 value of the grandmaster clock. The value is useful in BMC algorithm.\"",
"::=",
"{",
"raisecomPtpParent",
"6",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
255
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Indicates the priority1 value of the grandmaster clock. The value is useful in BMC algorithm."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: RAISECOM-PTP-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'MacAddress', 'RowStatus'], 'SWITCH-TC': ['EnableVar'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32'], 'RAISECOM-BASE-MIB': ['raisecomAgent'], 'SWITCH-SYSTEM-MIB': ['rcPortIndex']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.8886.1.26.4.1 | raisecomPtpParentPortIdentity | 0 | 0 | |
| 1.3.6.1.4.1.8886.1.26.4.2 | raisecomPtpParentSatisticsFlag | 0 | 0 | |
| 1.3.6.1.4.1.8886.1.26.4.3 | raisecomPtpParentOffsetScaledLogVariance | 0 | 0 | |
| 1.3.6.1.4.1.8886.1.26.4.4 | raisecomPtpParentPhaseChangeRate | 0 | 0 | |
| 1.3.6.1.4.1.8886.1.26.4.5 | raisecomPtpGrandmasterIdentity | 0 | 0 | |
| 1.3.6.1.4.1.8886.1.26.4.7 | raisecomPtpGrandmasterPriority2 | 0 | 0 | |
| 1.3.6.1.4.1.8886.1.26.4.8 | raisecomPtpGrandmasterClockClass | 0 | 0 | |
| 1.3.6.1.4.1.8886.1.26.4.9 | raisecomPtpGrandmasterClockAccuracy | 0 | 0 | |
| 1.3.6.1.4.1.8886.1.26.4.10 | raisecomPtpGrandmasterOffsetScaledLogVariance | 0 | 0 |