¾Ö¶ËÄ£¿éµÄ¹âÄ£¿éÀàÐÍ
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.8886.2.1.5.1.1.158
¾Ö¶ËÄ£¿éµÄ¹âÄ£¿éÀàÐÍ
Identification
{1 3 6 1 4 1 8886 2 1 5 1 1 158}
Notes below names come from selected MIB definitions.
| Value | Name and source notes |
|---|---|
| 1 | optical-M |
| 2 | optical-S1 |
| 3 | optical-S2 |
| 4 | optical-S3 |
| 5 | optical-SS13 |
| 6 | optical-SS15 |
| 7 | optical-SS23 |
| 8 | optical-SS25 |
| 9 | optical-SS34 |
| 10 | optical-SS35 |
| 12 | optical-S15 kuanglili 20090826 s15¹âÄ£¿éÀàÐÍö¾ÙֵΪ12 |
| 15 | optical-SFP wangjunduo 20130508 SFP¹âÄ£¿éÀàÐÍö¾ÙֵΪ15 |
| 50 | optical-S1FC |
| 51 | optical-S1A |
| 52 | optical-S2A |
| 53 | optical-S3A |
| 100 | unknown-type |
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In RAISECOM-RCFT-MIB, the row index consists of these components in order:
rcftChassisIndex (INTEGER): one numeric subidentifier for the non-negative value.rcftSlotIndex (INTEGER): one numeric subidentifier for the non-negative value.An instance has the form .1.3.6.1.4.1.8886.2.1.5.1.1.158.<rcftChassisIndex>.<rcftSlotIndex>. Use values present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.8886.2.1.5.1.1.158
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
opticalModuleType OBJECT-TYPE
SYNTAX INTEGER
{
optical-M(1),
optical-S1(2),
optical-S2(3),
optical-S3(4),
optical-SS13(5),
optical-SS15(6),
optical-SS23(7),
optical-SS25(8),
--optical-SS3(9), kuanglili 20090519 ¸ù¾Ý¹«Ë¾¹æ·¶È¡Ïûss3¹âÍ·ÀàÐÍ
optical-SS34(9),
optical-SS35(10),
optical-S15(12), --kuanglili 20090826 s15¹âÄ£¿éÀàÐÍö¾ÙֵΪ12
optical-SFP(15), --wangjunduo 20130508 SFP¹âÄ£¿éÀàÐÍö¾ÙֵΪ15
optical-S1FC(50),
optical-S1A(51),
optical-S2A(52),
optical-S3A(53),
unknown-type(100)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
¾Ö¶ËÄ£¿éµÄ¹âÄ£¿éÀàÐÍ
"
::={rcftSlotStatEntry 158}
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
¾Ö¶ËÄ£¿éµÄ¹âÄ£¿éÀàÐÍ
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: opticalModuleType
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"opticalModuleType",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"optical-M",
"(",
"1",
")",
",",
"optical-S1",
"(",
"2",
")",
",",
"optical-S2",
"(",
"3",
")",
",",
"optical-S3",
"(",
"4",
")",
",",
"optical-SS13",
"(",
"5",
")",
",",
"optical-SS15",
"(",
"6",
")",
",",
"optical-SS23",
"(",
"7",
")",
",",
"optical-SS25",
"(",
"8",
")",
",",
"optical-SS34",
"(",
"9",
")",
",",
"optical-SS35",
"(",
"10",
")",
",",
"optical-S15",
"(",
"12",
")",
",",
"optical-SFP",
"(",
"15",
")",
",",
"optical-S1FC",
"(",
"50",
")",
",",
"optical-S1A",
"(",
"51",
")",
",",
"optical-S2A",
"(",
"52",
")",
",",
"optical-S3A",
"(",
"53",
")",
",",
"unknown-type",
"(",
"100",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\" ¾Ö¶ËÄ£¿éµÄ¹âÄ£¿éÀàÐÍ \"",
"::=",
"{",
"rcftSlotStatEntry",
"158",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"optical-M",
1
],
[
"optical-S1",
2
],
[
"optical-S2",
3
],
[
"optical-S3",
4
],
[
"optical-SS13",
5
],
[
"optical-SS15",
6
],
[
"optical-SS23",
7
],
[
"optical-SS25",
8
],
[
"optical-SS34",
9
],
[
"optical-SS35",
10
],
[
"optical-S15",
12
],
[
"optical-SFP",
15
],
[
"optical-S1FC",
50
],
[
"optical-S1A",
51
],
[
"optical-S2A",
52
],
[
"optical-S3A",
53
],
[
"unknown-type",
100
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"¾Ö¶ËÄ£¿éµÄ¹âÄ£¿éÀàÐÍ"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: RAISECOM-RCFT-MIB
See published definition above
{'RFC-1215': ['TRAP-TYPE'], 'SNMPv2-TC': ['DisplayString', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'Counter32', 'Gauge32', 'OBJECT-TYPE', 'enterprises', 'TimeTicks', 'IpAddress', 'mib-2', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages:
Registration