For diameter, specify the maximum number of switches between any two end stations, only for CIST.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.8886.6.1.24.2.13
For diameter, specify the maximum number of switches between any two end stations, only for CIST.
Identification
{1 3 6 1 4 1 8886 6 1 24 2 13}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.8886.6.1.24.2.13.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
rcMstpBridgeDiameter OBJECT-TYPE
SYNTAX Unsigned32 (2..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For diameter, specify the maximum number of switches
between any two end stations, only for CIST. "
DEFVAL { 7 }
::= { rcMstpBridge 13 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
For diameter, specify the maximum number of switches between any two end stations, only for CIST.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: rcMstpBridgeDiameter
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rcMstpBridgeDiameter",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"2",
".",
".",
"7",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"For diameter, specify the maximum number of switches between any two end stations, only for CIST. \"",
"DEFVAL",
"{",
"7",
"}",
"::=",
"{",
"rcMstpBridge",
"13",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
2,
7
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"For diameter, specify the maximum number of switches between any two end stations, only for CIST."
],
null,
null,
null,
[
"DEFVAL",
7
]
]
}Vendor MIB copy from the Observium Community archive.
Module: SWITCH-MSTP-MIB
See published definition above
{'SNMPv2-TC': ['TruthValue', 'TimeStamp', 'DisplayString', 'RowStatus'], 'SWITCH-TC': ['Vlanset'], 'BRIDGE-MIB': ['BridgeId'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Counter32', 'Integer32', 'Unsigned32', 'NOTIFICATION-TYPE'], 'RAISECOM-BASE-MIB': ['iscomSwitch']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.8886.6.1.24.2.1 | rcMstpBridgeAdminStp | 0 | 0 | |
| 1.3.6.1.4.1.8886.6.1.24.2.2 | rcMstpBridgeMaxHops | 0 | 0 | |
| 1.3.6.1.4.1.8886.6.1.24.2.3 | rcMstpBridgeVersionSupported | 0 | 0 | |
| 1.3.6.1.4.1.8886.6.1.24.2.4 | rcMstpBridgeProtocolVersion | 0 | 0 | |
| 1.3.6.1.4.1.8886.6.1.24.2.5 | rcMstpBridgeRegionFormatSelector | 0 | 0 | |
| 1.3.6.1.4.1.8886.6.1.24.2.6 | rcMstpBridgeRegionName | 0 | 0 | |
| 1.3.6.1.4.1.8886.6.1.24.2.7 | rcMstpBridgeRegionEditName | 0 | 0 | |
| 1.3.6.1.4.1.8886.6.1.24.2.8 | rcMstpBridgeRegionRevLevel | 0 | 0 | |
| 1.3.6.1.4.1.8886.6.1.24.2.9 | rcMstpBridgeRegionEditRevLevel | 0 | 0 | |
| 1.3.6.1.4.1.8886.6.1.24.2.10 | rcMstpBridgeRegionDigest | 0 | 0 | |
| 1.3.6.1.4.1.8886.6.1.24.2.11 | rcMstpBridgeCistRoot | 0 | 0 | |
| 1.3.6.1.4.1.8886.6.1.24.2.12 | rcMstpBridgeCistExternalRootCost | 0 | 0 | |
| 1.3.6.1.4.1.8886.6.1.24.2.14 | rcMstpBridgeRegionEditBufferOperation | 0 | 0 |