Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rcErpsGuardTime",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"20",
".",
".",
"2000",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The guard timer is used to prevent Ethernet ring nodes from acting upon outdated R-APS messages and prevents the possibility of forming a closed loop. The period of the guard timer may be configured by the operator in 10 ms steps between 10 ms and 2 seconds, with a default value of 500 ms.\"",
"DEFVAL",
"{",
"500",
"}",
"::=",
"{",
"rcErpsCfgEntry",
"12",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
20,
2000
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The guard timer is used to prevent Ethernet ring nodes from acting upon outdated R-APS messages and prevents the possibility of forming a closed loop. The period of the guard timer may be configured by the operator in 10 ms steps between 10 ms and 2 seconds, with a default value of 500 ms."
],
null,
null,
null,
[
"DEFVAL",
500
]
]
}