Status in source: current.
Names: rlCdpValidateMandatoryTlvs
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rlCdpValidateMandatoryTlvs",
"OBJECT-TYPE",
"SYNTAX",
"TruthValue",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"By setting the MIB to true all mandatory TLVs 0x0001-0x0006 will be validated. Incoming CDP frames without any of the TLVs will be dropped. A value of false indicates that only the Device ID TLV (0x0001) is mandatory. Frames containing Device ID TLV will be processed, regardless of whether other TLVs are present or not.\"",
"DEFVAL",
"{",
"true",
"}",
"::=",
"{",
"rlCdp",
"18",
"}"
],
"syntax_tree": [
[
"row",
"TruthValue"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"By setting the MIB to true all mandatory TLVs 0x0001-0x0006 will be validated. Incoming CDP frames without any of the TLVs will be dropped. A value of false indicates that only the Device ID TLV (0x0001) is mandatory. Frames containing Device ID TLV will be processed, regardless of whether other TLVs are present or not."
],
null,
null,
null,
[
"DEFVAL",
"true"
]
]
}
- Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Module: RADLAN-CDP-MIB
See published definition above
Module imports
{'IF-MIB': ['InterfaceIndexOrZero', 'InterfaceIndex'], 'CISCO-TC': ['CiscoNetworkProtocol', 'CiscoNetworkAddress'], 'SNMPv2-TC': ['DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress', 'TruthValue'], 'RADLAN-MIB': ['rnd', 'rndNotifications'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'IpAddress', 'Unsigned32', 'MODULE-IDENTITY', 'Counter32'], 'Q-BRIDGE-MIB': ['PortList', 'VlanId'], 'CISCO-CDP-MIB': ['cdpCacheEntry', 'cdpCacheIfIndex', 'cdpCacheDeviceIndex'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'RADLAN-DEVICEPARAMS-MIB': ['rndErrorDesc', 'rndErrorSeverity']}
· Download RADLAN-CDP-MIB
Related source files and packages:
- NETGEAR official product and EOL MIB downloads
· Publisher's source file: Source package: MS510TX_TXPP_MIBS_V6.7.0.43.zip
Module: RADLAN-CDP-MIB
Same published definition
Module imports
{'IF-MIB': ['InterfaceIndexOrZero', 'InterfaceIndex'], 'CISCO-TC': ['CiscoNetworkProtocol', 'CiscoNetworkAddress'], 'SNMPv2-TC': ['DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress', 'TruthValue'], 'RADLAN-MIB': ['rnd', 'rndNotifications'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'IpAddress', 'Unsigned32', 'MODULE-IDENTITY', 'Counter32'], 'Q-BRIDGE-MIB': ['PortList', 'VlanId'], 'CISCO-CDP-MIB': ['cdpCacheEntry', 'cdpCacheIfIndex', 'cdpCacheDeviceIndex'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'RADLAN-DEVICEPARAMS-MIB': ['rndErrorDesc', 'rndErrorSeverity']}
· Download rlCDP.mib
Related source files and packages:
Same file in MX510TX_MS510TXPP_MIBS_ODM_V6.7.0.42.zip.
Same file in MS510TX_TXPP_V6.7.0.37_MIB_V6.7.0.37.zip.
- NETGEAR official product and EOL MIB downloads
· Publisher's source file: Source package: XS728T_XS748T_MIB_V6.5.1.26.zip
Module: RADLAN-CDP-MIB
Same published definition
Module imports
{'IF-MIB': ['InterfaceIndexOrZero', 'InterfaceIndex'], 'SNMPv2-TC': ['DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress', 'TruthValue'], 'RADLAN-MIB': ['rnd', 'rndNotifications'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'IpAddress', 'Unsigned32', 'MODULE-IDENTITY', 'Counter32'], 'Q-BRIDGE-MIB': ['PortList', 'VlanId'], 'CISCO-CDP-MIB': ['cdpCacheEntry', 'cdpCacheIfIndex', 'cdpCacheDeviceIndex'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'RADLAN-DEVICEPARAMS-MIB': ['rndErrorDesc', 'rndErrorSeverity']}
· Download rlCDP.mib
Related source files and packages:
Show more related files and packages
Same file in MIB-6.5.1.22.zip.
Same file in XS728T_XS748T_mib_files.zip.
Same file in XS728T_XS748T_MIB_V6.5.1.59.zip.
Same file in XS728T_XS748T_MIB_V6.5.1.30.zip.