Whether this port is an Edge port, and should start forwarding immediately.
Sources for this description
Radware MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.89.30.8.1.5
Whether this port is an Edge port, and should start forwarding immediately.
Identification
{1 3 6 1 4 1 89 30 8 1 5}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
rsStpPortModeFast OBJECT-TYPE
SYNTAX FeatureStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Whether this port is an Edge port, and should start forwarding immediately."
::= { rsStpPortEntry 5 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Whether this port is an Edge port, and should start forwarding immediately.
Radware MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: rsStpPortModeFast
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rsStpPortModeFast",
"OBJECT-TYPE",
"SYNTAX",
"FeatureStatus",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Whether this port is an Edge port, and should start forwarding immediately.\"",
"::=",
"{",
"rsStpPortEntry",
"5",
"}"
],
"syntax_tree": [
[
"row",
"FeatureStatus"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Whether this port is an Edge port, and should start forwarding immediately."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive. Radware support.
Module: RADWARE-MIB
See published definition above
{'IPV6-TC': ['Ipv6Address'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'SNMPv2-TC': ['TimeStamp'], 'RFC1155-SMI': ['NetworkAddress', 'IpAddress', 'Counter', 'Gauge', 'enterprises'], 'RFC1213-MIB': ['DisplayString', 'PhysAddress', 'ipAddrEntry']}Related source files and packages:
Vendor MIB copy from the Observium Community archive. Radware support.
Module: RADWARE-MIB
{'IPV6-TC': ['Ipv6Address'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'SNMPv2-TC': ['TimeStamp'], 'RFC1155-SMI': ['NetworkAddress', 'IpAddress', 'Counter', 'Gauge', 'enterprises'], 'RFC1213-MIB': ['DisplayString', 'PhysAddress', 'ipAddrEntry']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.89.30.8.1.1 | rsStpPortId | 0 | 0 | |
| 1.3.6.1.4.1.89.30.8.1.2 | rsStpPortVlanId | 0 | 0 | |
| 1.3.6.1.4.1.89.30.8.1.3 | rsStpPortPriority | 0 | 0 | |
| 1.3.6.1.4.1.89.30.8.1.4 | rsStpPortPathCost | 0 | 0 | |
| 1.3.6.1.4.1.89.30.8.1.6 | rsStpPortEnabled | 0 | 0 | |
| 1.3.6.1.4.1.89.30.8.1.7 | rsStpPortState | 0 | 0 | |
| 1.3.6.1.4.1.89.30.8.1.8 | rsStpPortRole | 0 | 0 |