Current value for the Sensor5 being instrumented.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.89.53.15.1.18
Current value for the Sensor5 being instrumented.
Identification
{1 3 6 1 4 1 89 53 15 1 18}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
rlPhdUnitEnvParamTempSensor5Value OBJECT-TYPE
SYNTAX EntitySensorValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current value for the Sensor5 being instrumented."
::= { rlPhdUnitEnvParamEntry 18 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Current value for the Sensor5 being instrumented.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: rlPhdUnitEnvParamTempSensor5Value
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rlPhdUnitEnvParamTempSensor5Value",
"OBJECT-TYPE",
"SYNTAX",
"EntitySensorValue",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Current value for the Sensor5 being instrumented.\"",
"::=",
"{",
"rlPhdUnitEnvParamEntry",
"18",
"}"
],
"syntax_tree": [
[
"row",
"EntitySensorValue"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Current value for the Sensor5 being instrumented."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: RADLAN-Physicaldescription-MIB
See published definition above
{'IF-MIB': ['InterfaceIndexOrZero', 'ifIndex', 'InterfaceIndex'], 'MAU-MIB': ['JackType'], 'SNMPv2-TC': ['DisplayString', 'PhysAddress', 'RowStatus'], 'RADLAN-MIB': ['rnd', 'rndNotifications'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'TimeTicks', 'NOTIFICATION-TYPE'], 'ENTITY-SENSOR-MIB': ['EntitySensorStatus', 'EntitySensorValue'], 'RADLAN-HWENVIROMENT': ['RlEnvMonState'], 'RADLAN-DEVICEPARAMS-MIB': ['rndErrorDesc', 'rndErrorSeverity']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: RADLAN-Physicaldescription-old-MIB
{'IF-MIB': ['InterfaceIndexOrZero', 'ifIndex', 'InterfaceIndex'], 'MAU-MIB': ['JackType'], 'SNMPv2-TC': ['DisplayString', 'PhysAddress', 'RowStatus'], 'RADLAN-MIB': ['rnd', 'rndNotifications'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'TimeTicks', 'NOTIFICATION-TYPE'], 'ENTITY-SENSOR-MIB': ['EntitySensorStatus', 'EntitySensorValue'], 'RADLAN-HWENVIROMENT': ['RlEnvMonState'], 'RADLAN-DEVICEPARAMS-MIB': ['rndErrorDesc', 'rndErrorSeverity']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.89.53.15.1.1 | rlPhdUnitEnvParamStackUnit | 0 | 0 | |
| 1.3.6.1.4.1.89.53.15.1.2 | rlPhdUnitEnvParamMainPSStatus | 0 | 0 | |
| 1.3.6.1.4.1.89.53.15.1.3 | rlPhdUnitEnvParamRedundantPSStatus | 0 | 0 | |
| 1.3.6.1.4.1.89.53.15.1.4 | rlPhdUnitEnvParamFan1Status | 0 | 0 | |
| 1.3.6.1.4.1.89.53.15.1.5 | rlPhdUnitEnvParamFan2Status | 0 | 0 | |
| 1.3.6.1.4.1.89.53.15.1.6 | rlPhdUnitEnvParamFan3Status | 0 | 0 | |
| 1.3.6.1.4.1.89.53.15.1.7 | rlPhdUnitEnvParamFan4Status | 0 | 0 | |
| 1.3.6.1.4.1.89.53.15.1.8 | rlPhdUnitEnvParamFan5Status | 0 | 0 | |
| 1.3.6.1.4.1.89.53.15.1.9 | rlPhdUnitEnvParamTempSensorValue, rlPhdUnitEnvParamFan6Status | 0 | 0 | |
| 1.3.6.1.4.1.89.53.15.1.10 | rlPhdUnitEnvParamTempSensorStatus, rlPhdUnitEnvParamTempSensorValue | 0 | 0 | |
| 1.3.6.1.4.1.89.53.15.1.11 | rlPhdUnitEnvParamUpTime, rlPhdUnitEnvParamTempSensorStatus | 0 | 0 | |
| 1.3.6.1.4.1.89.53.15.1.12 | rlPhdUnitEnvParamTempSensor2Value, rlPhdUnitEnvParamTempSensorWarningThresholdValue, rlPhdUnitEnvParamMonitorAutoRecoveryEnable | 0 | 0 | |
| 1.3.6.1.4.1.89.53.15.1.13 | rlPhdUnitEnvParamTempSensor2Status, rlPhdUnitEnvParamTempSensorCriticalThresholdValue, rlPhdUnitEnvParamMonitorTemperatureStatus | 0 | 0 | |
| 1.3.6.1.4.1.89.53.15.1.14 | rlPhdUnitEnvParamTempSensor3Value, rlPhdUnitEnvParamUpTime, rlPhdUnitEnvParamMonitorOperStatus | 0 | 0 | |
| 1.3.6.1.4.1.89.53.15.1.15 | rlPhdUnitEnvParamTempSensor3Status, rlPhdUnitEnvParamMonitorAutoRecoveryEnable | 0 | 0 | |
| 1.3.6.1.4.1.89.53.15.1.16 | rlPhdUnitEnvParamTempSensor4Value, rlPhdUnitEnvParamMonitorTemperatureStatus | 0 | 0 | |
| 1.3.6.1.4.1.89.53.15.1.17 | rlPhdUnitEnvParamTempSensor4Status, rlPhdUnitEnvParamMonitorOperStatus | 0 | 0 | |
| 1.3.6.1.4.1.89.53.15.1.19 | rlPhdUnitEnvParamTempSensor5Status | 0 | 0 |