Enter a number from 0 to 256 to specified how many control packets this port can receive or transmit per second. 0 means no rate limit.
Sources for this description
Zyxel official Download Library MIBsZyxel MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.890.1.15.3.16.1.1.1.3
Enter a number from 0 to 256 to specified how many control packets this port can receive or transmit per second. 0 means no rate limit.
Identification
{1 3 6 1 4 1 890 1 15 3 16 1 1 1 3}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In ZYXEL-CPU-PROTECTION-MIB, the row index consists of these components in order:
zyCpuProtectionPort (INTEGER): one numeric subidentifier for the non-negative value.zyCpuProtectionReasonType (INTEGER): one numeric subidentifier for the non-negative value.An instance has the form .1.3.6.1.4.1.890.1.15.3.16.1.1.1.3.<zyCpuProtectionPort>.<zyCpuProtectionReasonType>. Use values present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.890.1.15.3.16.1.1.1.3
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Product context
The Zyxel catalogue lists MIB packages containing this definition for these models:
A definition in a model's MIB package does not establish that the device implements it or permits access.
The displayed source records contain one distinct definition. Compare its source records.
zyCpuProtectionRateLimit OBJECT-TYPE
SYNTAX INTEGER(0..256)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enter a number from 0 to 256 to specified how many control packets this port can receive or transmit per second.
0 means no rate limit."
::= { zyxelCpuProtectionEntry 3}
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Enter a number from 0 to 256 to specified how many control packets this port can receive or transmit per second. 0 means no rate limit.
Zyxel official Download Library MIBsZyxel MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: zyCpuProtectionRateLimit
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"zyCpuProtectionRateLimit",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"0",
".",
".",
"256",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Enter a number from 0 to 256 to specified how many control packets this port can receive or transmit per second. 0 means no rate limit.\"",
"::=",
"{",
"zyxelCpuProtectionEntry",
"3",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
0,
256
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Enter a number from 0 to 256 to specified how many control packets this port can receive or transmit per second. 0 means no rate limit."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Zyxel support.
Module: ZYXEL-CPU-PROTECTION-MIB
See published definition above
{'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY'], 'ZYXEL-ES-SMI': ['esMgmt']}Related source files and packages:
Module: ZYXEL-CPU-PROTECTION-MIB
{'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY'], 'ZYXEL-ES-SMI': ['esMgmt']}Related source files and packages:
Same file in XS3800-28_8.zip.
Same file in XS1935-12F_3.zip.
Same file in XS1930-12HP_12.zip.
Same file in XMG2230-28HP_2.zip.
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.890.1.15.3.16.1.1.1.1 | zyCpuProtectionPort | 0 | 0 | |
| 1.3.6.1.4.1.890.1.15.3.16.1.1.1.2 | zyCpuProtectionReasonType | 0 | 0 |