Description 1
Power source Previous Status (normal, error, absent, present, active, standby, N/A).
OID reference
1.3.6.1.4.1.890.1.15.3.26.1.4.2.1.5
Power source Previous Status (normal, error, absent, present, active, standby, N/A).
Identification
{1 3 6 1 4 1 890 1 15 3 26 1 4 2 1 5}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Product context
The Zyxel catalogue lists MIB packages containing this definition for these models:
CX4800-56F, GS1350-26HP, GS1915-24EP, GS1920-24HPv2, XMG2230-28HP, usg-flex-700h.
A definition in a model's MIB package does not establish that the device implements it or permits access.
Available source records contain 2 distinct definitions; some records may not include a definition.
zyHwMonitorPowerSourcePreviousStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Power source Previous Status (normal, error, absent, present, active, standby, N/A)."
::= { zyxelHwMonitorPowerSourceEntry 5 }zyHwMonitorPowerSourcePreviousStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Power source Previous Status (normal/error/absent/present)."
::= { zyxelHwMonitorPowerSourceEntry 5 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
Power source Previous Status (normal, error, absent, present, active, standby, N/A).
Description 2
Power source Previous Status (normal/error/absent/present).
Zyxel official Download Library MIBsZyxel MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: zyHwMonitorPowerSourcePreviousStatus
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"zyHwMonitorPowerSourcePreviousStatus",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Power source Previous Status (normal, error, absent, present, active, standby, N/A).\"",
"::=",
"{",
"zyxelHwMonitorPowerSourceEntry",
"5",
"}"
],
"syntax_tree": [
[
"row",
"DisplayString"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Power source Previous Status (normal, error, absent, present, active, standby, N/A)."
],
null,
null,
null,
null
]
}Module: ZYXEL-HW-MONITOR-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'ZYXEL-ES-SMI': ['esMgmt']}Related source files and packages:
Module: ZYXEL-HW-MONITOR-MIB
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'ZYXEL-ES-SMI': ['esMgmt']}Related source files and packages:
Same file in XS1935-12F_3.zip.
Same file in XGS2220-54HP_8.zip.
Same file in XGS1930-52HP_15.zip.
Same file in XGS1930-52_15.zip.
Module: ZYXEL-HW-MONITOR-MIB
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'ZYXEL-ES-SMI': ['esMgmt']}Related source files and packages:
Status in source: current.
Names: zyHwMonitorPowerSourcePreviousStatus
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"zyHwMonitorPowerSourcePreviousStatus",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Power source Previous Status (normal/error/absent/present).\"",
"::=",
"{",
"zyxelHwMonitorPowerSourceEntry",
"5",
"}"
],
"syntax_tree": [
[
"row",
"DisplayString"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Power source Previous Status (normal/error/absent/present)."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive. Zyxel support.
Module: ZYXEL-HW-MONITOR-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'ZYXEL-ES-SMI': ['esMgmt']}Related source files and packages:
Vendor MIB copy from the Observium Community archive. Zyxel support.
Module: ZYXEL-HW-MONITOR-MIB
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'ZYXEL-ES-SMI': ['esMgmt']}Related source files and packages:
Module: ZYXEL-HW-MONITOR-MIB
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'ZYXEL-ES-SMI': ['esMgmt']}Related source files and packages:
Same file in XS3800-28_8.zip.
Same file in XS1930-12HP_12.zip.
Same file in XMG1930-30HP_7.zip.
Same file in XMG1930-30_7.zip.
Module: ZYXEL-HW-MONITOR-MIB
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'ZYXEL-ES-SMI': ['esMgmt']}Related source files and packages:
Same file in XGS4600-52F_10.zip.
Module: ZYXEL-HW-MONITOR-MIB
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'ZYXEL-ES-SMI': ['esMgmt']}Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.
· Download ZYXEL-HW-MONITOR-MIB.MIBRelated source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.890.1.15.3.26.1.4.2.1.1 | zyHwMonitorPowerSourceIndex | 0 | 0 | |
| 1.3.6.1.4.1.890.1.15.3.26.1.4.2.1.2 | zyHwMonitorPowerSourceType | 0 | 0 | |
| 1.3.6.1.4.1.890.1.15.3.26.1.4.2.1.3 | zyHwMonitorPowerSourceStatus | 0 | 0 | |
| 1.3.6.1.4.1.890.1.15.3.26.1.4.2.1.4 | zyHwMonitorPowerSourceDescription | 0 | 0 |