Name of Monitor Item
Sources for this description
Zyxel MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.890.1.5.12.47.12.21.1.1.2
Name of Monitor Item
Identification
{1 3 6 1 4 1 890 1 5 12 47 12 21 1 1 2}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
monitorItemName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of Monitor Item"
::= { monitorItemEntry 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Name of Monitor Item
Zyxel MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: monitorItemName
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"monitorItemName",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Name of Monitor Item\"",
"::=",
"{",
"monitorItemEntry",
"2",
"}"
],
"syntax_tree": [
[
"row",
"DisplayString"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Name of Monitor Item"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Zyxel support.
Module: ZYXEL-ves1724-56-Fanless-MIB
See published definition above
{'IF-MIB': ['InterfaceIndexOrZero', 'ifIndex'], 'IPV6-TC': ['Ipv6Address', 'Ipv6AddressPrefix'], 'SNMPv2-TC': ['RowStatus', 'DateAndTime', 'TruthValue', 'StorageType', 'MacAddress'], 'BRIDGE-MIB': ['dot1dBasePort', 'BridgeId', 'Timeout'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'IpAddress', 'NOTIFICATION-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString', 'sysObjectID'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList', 'dot1qVlanIndex'], 'VDSL-LINE-MIB': ['vdslLineConfProfileName', 'vdslLineAlarmConfProfileName', 'vdslPerf1DayIntervalNumber', 'vdslPhysSide', 'vdslPerfIntervalNumber'], 'VDSL2-LINE-MIB': ['xdsl2PMChHist1DInterval', 'xdsl2LineBand', 'xdsl2SCStatusSegment', 'xdsl2LineSegmentDirection', 'xdsl2LineSegment', 'xdsl2ChStatusUnit', 'xdsl2SCStatusDirection', 'xdsl2SCStatusBand', 'xdsl2PMLHist15MUnit', 'xdsl2PMLHist15MInterval', 'xdsl2PMLHist1DUnit', 'xdsl2PMLHist1DInterval', 'xdsl2PMChCurrUnit', 'xdsl2PMChHist15MUnit', 'xdsl2PMChHist15MInterval', 'xdsl2PMLCurrUnit', 'xdsl2PMChHist1DUnit', 'xdsl2LConfTempTemplateName', 'xdsl2LConfProfProfileName', 'xdsl2ChConfProfProfileName', 'xdsl2LAlarmConfTempTemplateName', 'xdsl2LineAlarmConfProfileName', 'xdsl2ChAlarmConfProfileName'], 'DISMAN-PING-MIB': ['OperationResponseStatus'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'VDSL2-LINE-TC-MIB': ['Xdsl2RaMode', 'Xdsl2LineLdsf'], 'HC-PerfHist-TC-MIB': ['HCPerfIntervalThreshold', 'HCPerfTimeElapsed'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.890.1.5.12.47.12.21.1.1.1 | monitorItemIndex | 0 | 0 | |
| 1.3.6.1.4.1.890.1.5.12.47.12.21.1.1.3 | monitorItemThreshold | 0 | 0 |