OID reference

xdsl2LConfProfSosMultiStepDs

1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.12

Description

Indicates the capabilities of the VTU-R to execute the SOS request in one step or in multiple steps in the downstream direction. The field is formatted as [gggg 0000]. The first four MSBs [gggg] indicate the maximum number of tones (GSOS) that can be executed in a single step (GSOS)in the downstream direction. The val…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1 (xdsl2ExtLineConfProfEntry)
Node code
12
Node name
xdsl2LConfProfSosMultiStepDs
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.12
URN notation
urn:oid:1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.12
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 890 1 5 12 47 60 5 1 2 1 12}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-56fanless(47) vdsl2Ext(60) xdsl2ExtProfile(5) xdsl2ExtProfileLine(1) xdsl2ExtLineConfProfTable(2) xdsl2ExtLineConfProfEntry(1) xdsl2LConfProfSosMultiStepDs(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-56fanless(47) vdsl2Ext(60) xdsl2ExtProfile(5) xdsl2ExtProfileLine(1) xdsl2ExtLineConfProfTable(2) xdsl2ExtLineConfProfEntry(1) xdsl2LConfProfSosMultiStepDs(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-56fanless(47) vdsl2Ext(60) xdsl2ExtProfile(5) xdsl2ExtProfileLine(1) xdsl2ExtLineConfProfTable(2) xdsl2ExtLineConfProfEntry(1) xdsl2LConfProfSosMultiStepDs(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-56fanless(47) vdsl2Ext(60) xdsl2ExtProfile(5) xdsl2ExtProfileLine(1) xdsl2ExtLineConfProfTable(2) xdsl2ExtLineConfProfEntry(1) xdsl2LConfProfSosMultiStepDs(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-56fanless(47) vdsl2Ext(60) xdsl2ExtProfile(5) xdsl2ExtProfileLine(1) xdsl2ExtLineConfProfTable(2) xdsl2ExtLineConfProfEntry(1) xdsl2LConfProfSosMultiStepDs(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-56fanless(47) vdsl2Ext(60) xdsl2ExtProfile(5) xdsl2ExtProfileLine(1) xdsl2ExtLineConfProfTable(2) xdsl2ExtLineConfProfEntry(1) xdsl2LConfProfSosMultiStepDs(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-56fanless(47) vdsl2Ext(60) xdsl2ExtProfile(5) xdsl2ExtProfileLine(1) xdsl2ExtLineConfProfTable(2) xdsl2ExtLineConfProfEntry(1) xdsl2LConfProfSosMultiStepDs(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-56fanless(47) vdsl2Ext(60) xdsl2ExtProfile(5) xdsl2ExtProfileLine(1) xdsl2ExtLineConfProfTable(2) xdsl2ExtLineConfProfEntry(1) xdsl2LConfProfSosMultiStepDs(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-56fanless(47) vdsl2Ext(60) xdsl2ExtProfile(5) xdsl2ExtProfileLine(1) xdsl2ExtLineConfProfTable(2) xdsl2ExtLineConfProfEntry(1) xdsl2LConfProfSosMultiStepDs(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-56fanless(47) vdsl2Ext(60) xdsl2ExtProfile(5) xdsl2ExtProfileLine(1) xdsl2ExtLineConfProfTable(2) xdsl2ExtLineConfProfEntry(1) xdsl2LConfProfSosMultiStepDs(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-56fanless(47) vdsl2Ext(60) xdsl2ExtProfile(5) xdsl2ExtProfileLine(1) xdsl2ExtLineConfProfTable(2) xdsl2ExtLineConfProfEntry(1) xdsl2LConfProfSosMultiStepDs(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-56fanless(47) vdsl2Ext(60) xdsl2ExtProfile(5) xdsl2ExtProfileLine(1) xdsl2ExtLineConfProfTable(2) xdsl2ExtLineConfProfEntry(1) xdsl2LConfProfSosMultiStepDs(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-56fanless(47) vdsl2Ext(60) xdsl2ExtProfile(5) xdsl2ExtProfileLine(1) xdsl2ExtLineConfProfTable(2) xdsl2ExtLineConfProfEntry(1) xdsl2LConfProfSosMultiStepDs(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-56fanless(47) vdsl2Ext(60) xdsl2ExtProfile(5) xdsl2ExtProfileLine(1) xdsl2ExtLineConfProfTable(2) xdsl2ExtLineConfProfEntry(1) xdsl2LConfProfSosMultiStepDs(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-56fanless(47) vdsl2Ext(60) xdsl2ExtProfile(5) xdsl2ExtProfileLine(1) xdsl2ExtLineConfProfTable(2) xdsl2ExtLineConfProfEntry(1) xdsl2LConfProfSosMultiStepDs(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-56fanless(47) vdsl2Ext(60) xdsl2ExtProfile(5) xdsl2ExtProfileLine(1) xdsl2ExtLineConfProfTable(2) xdsl2ExtLineConfProfEntry(1) xdsl2LConfProfSosMultiStepDs(12)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/890/1/5/12/47/60/5/1/2/1/12
  • /ISO/Identified-Organization/6/1/4/1/890/1/5/12/47/60/5/1/2/1/12
  • /ISO/3/6/1/4/1/890/1/5/12/47/60/5/1/2/1/12
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/thermalSensorFailure/ves1724-56fanless/vdsl2Ext/xdsl2ExtProfile/xdsl2ExtProfileLine/xdsl2ExtLineConfProfTable/xdsl2ExtLineConfProfEntry/xdsl2LConfProfSosMultiStepDs
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/vesSeries/ves1724-56fanless/vdsl2Ext/xdsl2ExtProfile/xdsl2ExtProfileLine/xdsl2ExtLineConfProfTable/xdsl2ExtLineConfProfEntry/xdsl2LConfProfSosMultiStepDs
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/thermalSensorFailure/ves1724-56fanless/vdsl2Ext/xdsl2ExtProfile/xdsl2ExtProfileLine/xdsl2ExtLineConfProfTable/xdsl2ExtLineConfProfEntry/xdsl2LConfProfSosMultiStepDs
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/vesSeries/ves1724-56fanless/vdsl2Ext/xdsl2ExtProfile/xdsl2ExtProfileLine/xdsl2ExtLineConfProfTable/xdsl2ExtLineConfProfEntry/xdsl2LConfProfSosMultiStepDs
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/thermalSensorFailure/ves1724-56fanless/vdsl2Ext/xdsl2ExtProfile/xdsl2ExtProfileLine/xdsl2ExtLineConfProfTable/xdsl2ExtLineConfProfEntry/xdsl2LConfProfSosMultiStepDs
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/vesSeries/ves1724-56fanless/vdsl2Ext/xdsl2ExtProfile/xdsl2ExtProfileLine/xdsl2ExtLineConfProfTable/xdsl2ExtLineConfProfEntry/xdsl2LConfProfSosMultiStepDs
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/thermalSensorFailure/ves1724-56fanless/vdsl2Ext/xdsl2ExtProfile/xdsl2ExtProfileLine/xdsl2ExtLineConfProfTable/xdsl2ExtLineConfProfEntry/xdsl2LConfProfSosMultiStepDs
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/vesSeries/ves1724-56fanless/vdsl2Ext/xdsl2ExtProfile/xdsl2ExtProfileLine/xdsl2ExtLineConfProfTable/xdsl2ExtLineConfProfEntry/xdsl2LConfProfSosMultiStepDs
  • /iso/identified-organization/dod/internet/private/enterprise/zyXEL/products/accessSwitch/thermalSensorFailure/ves1724-56fanless/vdsl2Ext/xdsl2ExtProfile/xdsl2ExtProfileLine/xdsl2ExtLineConfProfTable/xdsl2ExtLineConfProfEntry/xdsl2LConfProfSosMultiStepDs
  • /iso/identified-organization/dod/internet/private/enterprise/zyXEL/products/accessSwitch/vesSeries/ves1724-56fanless/vdsl2Ext/xdsl2ExtProfile/xdsl2ExtProfileLine/xdsl2ExtLineConfProfTable/xdsl2ExtLineConfProfEntry/xdsl2LConfProfSosMultiStepDs
  • /iso/identified-organization/dod/internet/private/enterprise/zyXEL/Products/accessSwitch/thermalSensorFailure/ves1724-56fanless/vdsl2Ext/xdsl2ExtProfile/xdsl2ExtProfileLine/xdsl2ExtLineConfProfTable/xdsl2ExtLineConfProfEntry/xdsl2LConfProfSosMultiStepDs
  • /iso/identified-organization/dod/internet/private/enterprise/zyXEL/Products/accessSwitch/vesSeries/ves1724-56fanless/vdsl2Ext/xdsl2ExtProfile/xdsl2ExtProfileLine/xdsl2ExtLineConfProfTable/xdsl2ExtLineConfProfEntry/xdsl2LConfProfSosMultiStepDs
  • /iso/identified-organization/dod/internet/private/enterprises/ZyXEL/products/accessSwitch/thermalSensorFailure/ves1724-56fanless/vdsl2Ext/xdsl2ExtProfile/xdsl2ExtProfileLine/xdsl2ExtLineConfProfTable/xdsl2ExtLineConfProfEntry/xdsl2LConfProfSosMultiStepDs
  • /iso/identified-organization/dod/internet/private/enterprises/ZyXEL/products/accessSwitch/vesSeries/ves1724-56fanless/vdsl2Ext/xdsl2ExtProfile/xdsl2ExtProfileLine/xdsl2ExtLineConfProfTable/xdsl2ExtLineConfProfEntry/xdsl2LConfProfSosMultiStepDs
  • /iso/identified-organization/dod/internet/private/enterprises/ZyXEL/Products/accessSwitch/thermalSensorFailure/ves1724-56fanless/vdsl2Ext/xdsl2ExtProfile/xdsl2ExtProfileLine/xdsl2ExtLineConfProfTable/xdsl2ExtLineConfProfEntry/xdsl2LConfProfSosMultiStepDs
  • /iso/identified-organization/dod/internet/private/enterprises/ZyXEL/Products/accessSwitch/vesSeries/ves1724-56fanless/vdsl2Ext/xdsl2ExtProfile/xdsl2ExtProfileLine/xdsl2ExtLineConfProfTable/xdsl2ExtLineConfProfEntry/xdsl2LConfProfSosMultiStepDs
  • Additional combinations skipped.

SNMP properties

Value type
BITS
Maximum access defined by MIB
read-write
Status in MIB
current

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.

Published row index: xdsl2LConfProfProfileName.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.12

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

xdsl2LConfProfSosMultiStepDs OBJECT-TYPE
    SYNTAX BITS 
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "Indicates the capabilities of the VTU-R to execute the SOS request in one step or in
		multiple steps in the downstream direction. The field is formatted as [gggg 0000]. 
		The first four MSBs [gggg] indicate the maximum number of tones (GSOS) that can be 
		executed in a single step (GSOS)in the downstream direction. The valid values are:
		- [0000]: No limitation
		- [0010]: GSOS = 256 tones
		- [0011]: GSOS = 512 tones
		- [0100]: GSOS = 1024 tones"
    ::= { xdsl2ExtLineConfProfEntry 12 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Indicates the capabilities of the VTU-R to execute the SOS request in one step or in multiple steps in the downstream direction. The field is formatted as [gggg 0000]. The first four MSBs [gggg] indicate the maximum number of tones (GSOS) that can be executed in a single step (GSOS)in the downstream direction. The valid values are: - [0000]: No limitation - [0010]: GSOS = 256 tones - [0011]: GSOS = 512 tones - [0100]: GSOS = 1024 tones

Sources for this description

Zyxel MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1Zyxel MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

xdsl2LConfProfSosMultiStepDs · currentZyxel MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: xdsl2LConfProfSosMultiStepDs

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "xdsl2LConfProfSosMultiStepDs",
    "OBJECT-TYPE",
    "SYNTAX",
    "BITS",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Indicates the capabilities of the VTU-R to execute the SOS request in one step or in multiple steps in the downstream direction. The field is formatted as [gggg 0000]. The first four MSBs [gggg] indicate the maximum number of tones (GSOS) that can be executed in a single step (GSOS)in the downstream direction. The valid values are: - [0000]: No limitation - [0010]: GSOS = 256 tones - [0011]: GSOS = 512 tones - [0100]: GSOS = 1024 tones\"",
    "::=",
    "{",
    "xdsl2ExtLineConfProfEntry",
    "12",
    "}"
  ],
  "syntax_tree": [
    [
      "BITS",
      null
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Indicates the capabilities of the VTU-R to execute the SOS request in one step or in multiple steps in the downstream direction. The field is formatted as [gggg 0000]. The first four MSBs [gggg] indicate the maximum number of tones (GSOS) that can be executed in a single step (GSOS)in the downstream direction. The valid values are: - [0000]: No limitation - [0010]: GSOS = 256 tones - [0011]: GSOS = 512 tones - [0100]: GSOS = 1024 tones"
    ],
    null,
    null,
    null,
    null
  ]
}
  • Zyxel MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. Zyxel support.

    Module: ZYXEL-ves1724-56-Fanless-MIB

    See published definition above

    Module imports
    {'IF-MIB': ['InterfaceIndexOrZero', 'ifIndex'], 'IPV6-TC': ['Ipv6Address', 'Ipv6AddressPrefix'], 'SNMPv2-TC': ['RowStatus', 'DateAndTime', 'TruthValue', 'StorageType', 'MacAddress'], 'BRIDGE-MIB': ['dot1dBasePort', 'BridgeId', 'Timeout'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'IpAddress', 'NOTIFICATION-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString', 'sysObjectID'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList', 'dot1qVlanIndex'], 'VDSL-LINE-MIB': ['vdslLineConfProfileName', 'vdslLineAlarmConfProfileName', 'vdslPerf1DayIntervalNumber', 'vdslPhysSide', 'vdslPerfIntervalNumber'], 'VDSL2-LINE-MIB': ['xdsl2PMChHist1DInterval', 'xdsl2LineBand', 'xdsl2SCStatusSegment', 'xdsl2LineSegmentDirection', 'xdsl2LineSegment', 'xdsl2ChStatusUnit', 'xdsl2SCStatusDirection', 'xdsl2SCStatusBand', 'xdsl2PMLHist15MUnit', 'xdsl2PMLHist15MInterval', 'xdsl2PMLHist1DUnit', 'xdsl2PMLHist1DInterval', 'xdsl2PMChCurrUnit', 'xdsl2PMChHist15MUnit', 'xdsl2PMChHist15MInterval', 'xdsl2PMLCurrUnit', 'xdsl2PMChHist1DUnit', 'xdsl2LConfTempTemplateName', 'xdsl2LConfProfProfileName', 'xdsl2ChConfProfProfileName', 'xdsl2LAlarmConfTempTemplateName', 'xdsl2LineAlarmConfProfileName', 'xdsl2ChAlarmConfProfileName'], 'DISMAN-PING-MIB': ['OperationResponseStatus'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'VDSL2-LINE-TC-MIB': ['Xdsl2RaMode', 'Xdsl2LineLdsf'], 'HC-PerfHist-TC-MIB': ['HCPerfIntervalThreshold', 'HCPerfTimeElapsed'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}

    Source data warning: Publisher omitted the names and positions of BITS; the complete OID is preserved and bit assignments remain unknown

    · Download ZYXEL-ves1724-56-Fanless-MIB

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.890)

Harry Chou

Siblings (20)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.1 xdsl2LConfProfBitSwapDs00
1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.2 xdsl2LConfProfBitSwapUs00
1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.3 xdsl2LConfProfPortList00
1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.4 xdsl2LConfProfSosTimeDs00
1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.5 xdsl2LConfProfSosTimeUs00
1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.6 xdsl2LConfProfSosCrcDs00
1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.7 xdsl2LConfProfSosCrcUs00
1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.8 xdsl2LConfProfSosNToneDs00
1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.9 xdsl2LConfProfSosNToneUs00
1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.10 xdsl2LConfProfSosMaxDs00
1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.11 xdsl2LConfProfSosMaxUs00
1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.13 xdsl2LConfProfSosMultiStepUs00
1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.14 xdsl2LConfProfRocEnableDs00
1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.15 xdsl2LConfProfRocEnableUs00
1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.16 xdsl2LConfProfRocSnrmDs00
1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.17 xdsl2LConfProfRocSnrmUs00
1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.18 xdsl2LConfProfRocMinInpDs00
1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.19 xdsl2LConfProfRocMinInpUs00
1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.20 xdsl2LConfProfDynamicDepthDs00
1.3.6.1.4.1.890.1.5.12.47.60.5.1.2.1.21 xdsl2LConfProfDynamicDepthUs00