OID reference

sysMgmtSystemStatus

1.3.6.1.4.1.890.1.5.12.48.12.6

Description

This variable indicates the status of the system. The sysMgmtAlarmStatus is a bit map represented a sum, therefore, it can represent multiple defects simultaneously. The sysNoDefect should be set if and only if no other flag is set. The various bit positions are: 0 sysAlarmDetected 1 sysTemperatureError 2 sysFanRPMErr…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.890.1.5.12.48.12 (sysMgmt)
Node code
6
Node name
sysMgmtSystemStatus
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.890.1.5.12.48.12.6
URN notation
urn:oid:1.3.6.1.4.1.890.1.5.12.48.12.6
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 890 1 5 12 48 12 6}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55C(48) sysMgmt(12) sysMgmtSystemStatus(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55c(48) sysMgmt(12) sysMgmtSystemStatus(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55C(48) sysMgmt(12) sysMgmtSystemStatus(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55c(48) sysMgmt(12) sysMgmtSystemStatus(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55C(48) sysMgmt(12) sysMgmtSystemStatus(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55c(48) sysMgmt(12) sysMgmtSystemStatus(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55C(48) sysMgmt(12) sysMgmtSystemStatus(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55c(48) sysMgmt(12) sysMgmtSystemStatus(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55C(48) sysMgmt(12) sysMgmtSystemStatus(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55c(48) sysMgmt(12) sysMgmtSystemStatus(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55C(48) sysMgmt(12) sysMgmtSystemStatus(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55c(48) sysMgmt(12) sysMgmtSystemStatus(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55C(48) sysMgmt(12) sysMgmtSystemStatus(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55c(48) sysMgmt(12) sysMgmtSystemStatus(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55C(48) sysMgmt(12) sysMgmtSystemStatus(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55c(48) sysMgmt(12) sysMgmtSystemStatus(6)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/890/1/5/12/48/12/6
  • /ISO/Identified-Organization/6/1/4/1/890/1/5/12/48/12/6
  • /ISO/3/6/1/4/1/890/1/5/12/48/12/6
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/thermalSensorFailure/ves1724-55C/sysMgmt/sysMgmtSystemStatus
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/thermalSensorFailure/ves1724-55c/sysMgmt/sysMgmtSystemStatus
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/vesSeries/ves1724-55C/sysMgmt/sysMgmtSystemStatus
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/vesSeries/ves1724-55c/sysMgmt/sysMgmtSystemStatus
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/thermalSensorFailure/ves1724-55C/sysMgmt/sysMgmtSystemStatus
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/thermalSensorFailure/ves1724-55c/sysMgmt/sysMgmtSystemStatus
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/vesSeries/ves1724-55C/sysMgmt/sysMgmtSystemStatus
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/vesSeries/ves1724-55c/sysMgmt/sysMgmtSystemStatus
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/thermalSensorFailure/ves1724-55C/sysMgmt/sysMgmtSystemStatus
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/thermalSensorFailure/ves1724-55c/sysMgmt/sysMgmtSystemStatus
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/vesSeries/ves1724-55C/sysMgmt/sysMgmtSystemStatus
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/vesSeries/ves1724-55c/sysMgmt/sysMgmtSystemStatus
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/thermalSensorFailure/ves1724-55C/sysMgmt/sysMgmtSystemStatus
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/thermalSensorFailure/ves1724-55c/sysMgmt/sysMgmtSystemStatus
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/vesSeries/ves1724-55C/sysMgmt/sysMgmtSystemStatus
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/vesSeries/ves1724-55c/sysMgmt/sysMgmtSystemStatus
  • Additional combinations skipped.

SNMP properties

Value type
BITS
Maximum access defined by MIB
read-only
Status in MIB
current

Bit values

Bit positionName
0sysAlarmDetected
1sysTemperatureError
2sysFanRPMError
3sysVoltageRangeError
4sysExternalAlarm

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.890.1.5.12.48.12.6.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Product context

Documented MIB packages

The Zyxel catalogue lists MIB packages containing this definition for these models:

VES1724-55C.

A definition in a model's MIB package does not establish that the device implements it or permits access.

The displayed source records contain one distinct definition. Compare its source records.

sysMgmtSystemStatus OBJECT-TYPE
	SYNTAX	BITS {
		sysAlarmDetected(0),
		sysTemperatureError(1),
		sysFanRPMError(2),
		sysVoltageRangeError(3),
		sysExternalAlarm(4)
	}
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
		"This variable indicates the status of the system.
 		The sysMgmtAlarmStatus is a bit map represented
 		a sum, therefore, it can represent multiple defects
 		simultaneously. The sysNoDefect should be set if and only if
 		no other flag is set.

	 	The various bit positions are:
			0   sysAlarmDetected
			1   sysTemperatureError
			2   sysFanRPMError
			3   sysVoltageRangeError
			4   sysExternalAlarm"
        ::= { sysMgmt 6 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

This variable indicates the status of the system. The sysMgmtAlarmStatus is a bit map represented a sum, therefore, it can represent multiple defects simultaneously. The sysNoDefect should be set if and only if no other flag is set. The various bit positions are: 0 sysAlarmDetected 1 sysTemperatureError 2 sysFanRPMError 3 sysVoltageRangeError 4 sysExternalAlarm

Sources for this description

Zyxel official Download Library MIBs

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Zyxel official Download Library MIBs1 record · 1 source

Description 1

sysMgmtSystemStatus · currentZyxel official Download Library MIBs1 source

Status in source: current.

Names: sysMgmtSystemStatus

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "sysMgmtSystemStatus",
    "OBJECT-TYPE",
    "SYNTAX",
    "BITS",
    "{",
    "sysAlarmDetected",
    "(",
    "0",
    ")",
    ",",
    "sysTemperatureError",
    "(",
    "1",
    ")",
    ",",
    "sysFanRPMError",
    "(",
    "2",
    ")",
    ",",
    "sysVoltageRangeError",
    "(",
    "3",
    ")",
    ",",
    "sysExternalAlarm",
    "(",
    "4",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This variable indicates the status of the system. The sysMgmtAlarmStatus is a bit map represented a sum, therefore, it can represent multiple defects simultaneously. The sysNoDefect should be set if and only if no other flag is set. The various bit positions are: 0 sysAlarmDetected 1 sysTemperatureError 2 sysFanRPMError 3 sysVoltageRangeError 4 sysExternalAlarm\"",
    "::=",
    "{",
    "sysMgmt",
    "6",
    "}"
  ],
  "syntax_tree": [
    [
      "BITS",
      [
        [
          "sysAlarmDetected",
          0
        ],
        [
          "sysTemperatureError",
          1
        ],
        [
          "sysFanRPMError",
          2
        ],
        [
          "sysVoltageRangeError",
          3
        ],
        [
          "sysExternalAlarm",
          4
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This variable indicates the status of the system. The sysMgmtAlarmStatus is a bit map represented a sum, therefore, it can represent multiple defects simultaneously. The sysNoDefect should be set if and only if no other flag is set. The various bit positions are: 0 sysAlarmDetected 1 sysTemperatureError 2 sysFanRPMError 3 sysVoltageRangeError 4 sysExternalAlarm"
    ],
    null,
    null,
    null,
    null
  ]
}
  • Zyxel official Download Library MIBs · Publisher's source file: VES1724-55C_2.mib

    Module: ZYXEL-ves1724-55c-MIB

    See published definition above

    Module imports
    {'IF-MIB': ['InterfaceIndexOrZero', 'ifIndex'], 'IPV6-TC': ['Ipv6Address', 'Ipv6AddressPrefix'], 'SNMPv2-TC': ['RowStatus', 'DateAndTime', 'TruthValue', 'StorageType', 'MacAddress'], 'BRIDGE-MIB': ['dot1dBasePort', 'BridgeId', 'Timeout'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'IpAddress', 'NOTIFICATION-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString', 'sysObjectID'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList', 'dot1qVlanIndex'], 'VDSL-LINE-MIB': ['vdslLineConfProfileName', 'vdslLineAlarmConfProfileName', 'vdslPerf1DayIntervalNumber', 'vdslPhysSide', 'vdslPerfIntervalNumber'], 'VDSL2-LINE-MIB': ['xdsl2PMChHist1DInterval', 'xdsl2LineBand', 'xdsl2SCStatusSegment', 'xdsl2LineSegmentDirection', 'xdsl2LineSegment', 'xdsl2ChStatusUnit', 'xdsl2SCStatusDirection', 'xdsl2SCStatusBand', 'xdsl2PMLHist15MUnit', 'xdsl2PMLHist15MInterval', 'xdsl2PMLHist1DUnit', 'xdsl2PMLHist1DInterval', 'xdsl2PMChCurrUnit', 'xdsl2PMChHist15MUnit', 'xdsl2PMChHist15MInterval', 'xdsl2PMLCurrUnit', 'xdsl2PMChHist1DUnit', 'xdsl2LConfTempTemplateName', 'xdsl2LConfProfProfileName', 'xdsl2ChConfProfProfileName', 'xdsl2LAlarmConfTempTemplateName', 'xdsl2LineAlarmConfProfileName', 'xdsl2ChAlarmConfProfileName'], 'DISMAN-PING-MIB': ['OperationResponseStatus'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'VDSL2-LINE-TC-MIB': ['Xdsl2RaMode', 'Xdsl2LineLdsf'], 'HC-PerfHist-TC-MIB': ['HCPerfIntervalThreshold', 'HCPerfTimeElapsed'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download VES1724-55C_2.mib

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.890)

Harry Chou

Siblings (22)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.890.1.5.12.48.12.1 sysMgmtConfigSave00
1.3.6.1.4.1.890.1.5.12.48.12.2 sysMgmtBootupConfig00
1.3.6.1.4.1.890.1.5.12.48.12.3 sysMgmtReboot00
1.3.6.1.4.1.890.1.5.12.48.12.4 sysMgmtDefaultConfig00
1.3.6.1.4.1.890.1.5.12.48.12.5 sysMgmtLastActionStatus00
1.3.6.1.4.1.890.1.5.12.48.12.7 sysMgmtCPUUsage00
1.3.6.1.4.1.890.1.5.12.48.12.8 sysMgmtBootupImage00
1.3.6.1.4.1.890.1.5.12.48.12.9 sysMgmtCounterReset00
1.3.6.1.4.1.890.1.5.12.48.12.10 sysMgmtTftpServiceSetup88
1.3.6.1.4.1.890.1.5.12.48.12.11 sysMgmtRmtFwUpgradeSetup412
1.3.6.1.4.1.890.1.5.12.48.12.12 sysMgmtPacketBufferUsage00
1.3.6.1.4.1.890.1.5.12.48.12.13 sysMgmtMemoryUsage00
1.3.6.1.4.1.890.1.5.12.48.12.14 sysLoginSetup27
1.3.6.1.4.1.890.1.5.12.48.12.15 sysMgmtExternalAlarmSetup26
1.3.6.1.4.1.890.1.5.12.48.12.16 sysMgmtMacFlush00
1.3.6.1.4.1.890.1.5.12.48.12.17 sysMgmtCPUUsageThreshold00
1.3.6.1.4.1.890.1.5.12.48.12.18 sysMgmtPacketBufferThreshold00
1.3.6.1.4.1.890.1.5.12.48.12.19 sysMgmtMemoryUsageThreshold00
1.3.6.1.4.1.890.1.5.12.48.12.21 sysMgmtMonitorItemSetup15
1.3.6.1.4.1.890.1.5.12.48.12.22 sysMgmtPINTransform00
1.3.6.1.4.1.890.1.5.12.48.12.23 sysMgmtOnlineUser18
1.3.6.1.4.1.890.1.5.12.48.12.24 sysMgmtLoginMessage00