The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
OID reference
ifBondingInDiscards
1.3.6.1.4.1.890.1.5.12.48.121.2.7.1.20
Description
The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initiali…
Identification
Identifier and names
- Parent
- 1.3.6.1.4.1.890.1.5.12.48.121.2.7.1 (ifBondingStatusEntry)
- Node code
- 20
- Node name
- ifBondingInDiscards
- Category
- SNMP management object
- Numeric OID
- 1.3.6.1.4.1.890.1.5.12.48.121.2.7.1.20
- URN notation
- urn:oid:1.3.6.1.4.1.890.1.5.12.48.121.2.7.1.20
ASN.1, OID-IRI and named path variants
- ASN.1 notation
-
{1 3 6 1 4 1 890 1 5 12 48 121 2 7 1 20}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55C(48) bonding(121) bondingStatus(2) ifBondingStatusTable(7) ifBondingStatusEntry(1) ifBondingInDiscards(20)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55c(48) bonding(121) bondingStatus(2) ifBondingStatusTable(7) ifBondingStatusEntry(1) ifBondingInDiscards(20)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55C(48) bonding(121) bondingStatus(2) ifBondingStatusTable(7) ifBondingStatusEntry(1) ifBondingInDiscards(20)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55c(48) bonding(121) bondingStatus(2) ifBondingStatusTable(7) ifBondingStatusEntry(1) ifBondingInDiscards(20)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55C(48) bonding(121) bondingStatus(2) ifBondingStatusTable(7) ifBondingStatusEntry(1) ifBondingInDiscards(20)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55c(48) bonding(121) bondingStatus(2) ifBondingStatusTable(7) ifBondingStatusEntry(1) ifBondingInDiscards(20)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55C(48) bonding(121) bondingStatus(2) ifBondingStatusTable(7) ifBondingStatusEntry(1) ifBondingInDiscards(20)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55c(48) bonding(121) bondingStatus(2) ifBondingStatusTable(7) ifBondingStatusEntry(1) ifBondingInDiscards(20)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55C(48) bonding(121) bondingStatus(2) ifBondingStatusTable(7) ifBondingStatusEntry(1) ifBondingInDiscards(20)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55c(48) bonding(121) bondingStatus(2) ifBondingStatusTable(7) ifBondingStatusEntry(1) ifBondingInDiscards(20)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55C(48) bonding(121) bondingStatus(2) ifBondingStatusTable(7) ifBondingStatusEntry(1) ifBondingInDiscards(20)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55c(48) bonding(121) bondingStatus(2) ifBondingStatusTable(7) ifBondingStatusEntry(1) ifBondingInDiscards(20)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55C(48) bonding(121) bondingStatus(2) ifBondingStatusTable(7) ifBondingStatusEntry(1) ifBondingInDiscards(20)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55c(48) bonding(121) bondingStatus(2) ifBondingStatusTable(7) ifBondingStatusEntry(1) ifBondingInDiscards(20)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55C(48) bonding(121) bondingStatus(2) ifBondingStatusTable(7) ifBondingStatusEntry(1) ifBondingInDiscards(20)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55c(48) bonding(121) bondingStatus(2) ifBondingStatusTable(7) ifBondingStatusEntry(1) ifBondingInDiscards(20)}
- Additional combinations skipped.
- OID-IRI notation
- /1/3/6/1/4/1/890/1/5/12/48/121/2/7/1/20
- /ISO/Identified-Organization/6/1/4/1/890/1/5/12/48/121/2/7/1/20
- /ISO/3/6/1/4/1/890/1/5/12/48/121/2/7/1/20
- Named path variants
- /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/thermalSensorFailure/ves1724-55C/bonding/bondingStatus/ifBondingStatusTable/ifBondingStatusEntry/ifBondingInDiscards
- /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/thermalSensorFailure/ves1724-55c/bonding/bondingStatus/ifBondingStatusTable/ifBondingStatusEntry/ifBondingInDiscards
- /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/vesSeries/ves1724-55C/bonding/bondingStatus/ifBondingStatusTable/ifBondingStatusEntry/ifBondingInDiscards
- /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/vesSeries/ves1724-55c/bonding/bondingStatus/ifBondingStatusTable/ifBondingStatusEntry/ifBondingInDiscards
- /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/thermalSensorFailure/ves1724-55C/bonding/bondingStatus/ifBondingStatusTable/ifBondingStatusEntry/ifBondingInDiscards
- /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/thermalSensorFailure/ves1724-55c/bonding/bondingStatus/ifBondingStatusTable/ifBondingStatusEntry/ifBondingInDiscards
- /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/vesSeries/ves1724-55C/bonding/bondingStatus/ifBondingStatusTable/ifBondingStatusEntry/ifBondingInDiscards
- /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/vesSeries/ves1724-55c/bonding/bondingStatus/ifBondingStatusTable/ifBondingStatusEntry/ifBondingInDiscards
- /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/thermalSensorFailure/ves1724-55C/bonding/bondingStatus/ifBondingStatusTable/ifBondingStatusEntry/ifBondingInDiscards
- /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/thermalSensorFailure/ves1724-55c/bonding/bondingStatus/ifBondingStatusTable/ifBondingStatusEntry/ifBondingInDiscards
- /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/vesSeries/ves1724-55C/bonding/bondingStatus/ifBondingStatusTable/ifBondingStatusEntry/ifBondingInDiscards
- /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/vesSeries/ves1724-55c/bonding/bondingStatus/ifBondingStatusTable/ifBondingStatusEntry/ifBondingInDiscards
- /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/thermalSensorFailure/ves1724-55C/bonding/bondingStatus/ifBondingStatusTable/ifBondingStatusEntry/ifBondingInDiscards
- /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/thermalSensorFailure/ves1724-55c/bonding/bondingStatus/ifBondingStatusTable/ifBondingStatusEntry/ifBondingInDiscards
- /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/vesSeries/ves1724-55C/bonding/bondingStatus/ifBondingStatusTable/ifBondingStatusEntry/ifBondingInDiscards
- /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/vesSeries/ves1724-55c/bonding/bondingStatus/ifBondingStatusTable/ifBondingStatusEntry/ifBondingInDiscards
- Additional combinations skipped.
SNMP properties
- Value type
- Counter32
- Maximum access defined by MIB
- read-only
- Status in MIB
- current
Interpreting this counter
A counter is cumulative. To estimate a rate, subtract two readings and divide by the elapsed time; use the units stated in the MIB.
Counter values can wrap or reset. A decrease alone does not distinguish a wrap from a reset, and multiple wraps between readings cannot be recovered reliably. Check the device's discontinuity indicators when available.
Published counter width: 32 bits. SMIv2: Counter32 · Counter64
Using this OID with SNMP
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In ZYXEL-ves1724-55c-MIB, the row index ifBondingGroupId is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.890.1.5.12.48.121.2.7.1.20.<ifBondingGroupId>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.890.1.5.12.48.121.2.7.1.20
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Product context
Documented MIB packages
The Zyxel catalogue lists MIB packages containing this definition for these models:
A definition in a model's MIB package does not establish that the device implements it or permits access.
Published definition
The displayed source records contain one distinct definition. Compare its source records.
ifBondingInDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of inbound packets which were chosen to be
discarded even though no errors had been detected to prevent
their being deliverable to a higher-layer protocol. One
possible reason for discarding such a packet could be to
free up buffer space.
Discontinuities in the value of this counter can occur at
re-initialization of the management system, and at other
times as indicated by the value of
ifCounterDiscontinuityTime."
::= { ifBondingStatusEntry 20 }
Meaning
Descriptions
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Evidence
Source records
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Records for description 1Zyxel official Download Library MIBs
ifBondingInDiscards · currentZyxel official Download Library MIBs
Status in source: current.
Names: ifBondingInDiscards
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ifBondingInDiscards",
"OBJECT-TYPE",
"SYNTAX",
"Counter32",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.\"",
"::=",
"{",
"ifBondingStatusEntry",
"20",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Counter32"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime."
],
null,
null,
null,
null
]
}- Zyxel official Download Library MIBs
· Publisher's source file: VES1724-55C_2.mib
Module: ZYXEL-ves1724-55c-MIB
See published definition above
· Download VES1724-55C_2.mibModule imports
{'IF-MIB': ['InterfaceIndexOrZero', 'ifIndex'], 'IPV6-TC': ['Ipv6Address', 'Ipv6AddressPrefix'], 'SNMPv2-TC': ['RowStatus', 'DateAndTime', 'TruthValue', 'StorageType', 'MacAddress'], 'BRIDGE-MIB': ['dot1dBasePort', 'BridgeId', 'Timeout'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'IpAddress', 'NOTIFICATION-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString', 'sysObjectID'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList', 'dot1qVlanIndex'], 'VDSL-LINE-MIB': ['vdslLineConfProfileName', 'vdslLineAlarmConfProfileName', 'vdslPerf1DayIntervalNumber', 'vdslPhysSide', 'vdslPerfIntervalNumber'], 'VDSL2-LINE-MIB': ['xdsl2PMChHist1DInterval', 'xdsl2LineBand', 'xdsl2SCStatusSegment', 'xdsl2LineSegmentDirection', 'xdsl2LineSegment', 'xdsl2ChStatusUnit', 'xdsl2SCStatusDirection', 'xdsl2SCStatusBand', 'xdsl2PMLHist15MUnit', 'xdsl2PMLHist15MInterval', 'xdsl2PMLHist1DUnit', 'xdsl2PMLHist1DInterval', 'xdsl2PMChCurrUnit', 'xdsl2PMChHist15MUnit', 'xdsl2PMChHist15MInterval', 'xdsl2PMLCurrUnit', 'xdsl2PMChHist1DUnit', 'xdsl2LConfTempTemplateName', 'xdsl2LConfProfProfileName', 'xdsl2ChConfProfProfileName', 'xdsl2LAlarmConfTempTemplateName', 'xdsl2LineAlarmConfProfileName', 'xdsl2ChAlarmConfProfileName'], 'DISMAN-PING-MIB': ['OperationResponseStatus'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'VDSL2-LINE-TC-MIB': ['Xdsl2RaMode', 'Xdsl2LineLdsf'], 'HC-PerfHist-TC-MIB': ['HCPerfIntervalThreshold', 'HCPerfTimeElapsed'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
Registration