OID reference

tacacsAcctServerIpAddr

1.3.6.1.4.1.890.1.5.12.48.58.2.2.1.2

Description

IPv4 only

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.890.1.5.12.48.58.2.2.1 (tacacsAcctServerEntry)
Node code
2
Node name
tacacsAcctServerIpAddr
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.890.1.5.12.48.58.2.2.1.2
URN notation
urn:oid:1.3.6.1.4.1.890.1.5.12.48.58.2.2.1.2
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 890 1 5 12 48 58 2 2 1 2}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55C(48) tacacsServerSetup(58) tacacsAcctServerSetup(2) tacacsAcctServerTable(2) tacacsAcctServerEntry(1) tacacsAcctServerIpAddr(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55c(48) tacacsServerSetup(58) tacacsAcctServerSetup(2) tacacsAcctServerTable(2) tacacsAcctServerEntry(1) tacacsAcctServerIpAddr(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55C(48) tacacsServerSetup(58) tacacsAcctServerSetup(2) tacacsAcctServerTable(2) tacacsAcctServerEntry(1) tacacsAcctServerIpAddr(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55c(48) tacacsServerSetup(58) tacacsAcctServerSetup(2) tacacsAcctServerTable(2) tacacsAcctServerEntry(1) tacacsAcctServerIpAddr(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55C(48) tacacsServerSetup(58) tacacsAcctServerSetup(2) tacacsAcctServerTable(2) tacacsAcctServerEntry(1) tacacsAcctServerIpAddr(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55c(48) tacacsServerSetup(58) tacacsAcctServerSetup(2) tacacsAcctServerTable(2) tacacsAcctServerEntry(1) tacacsAcctServerIpAddr(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55C(48) tacacsServerSetup(58) tacacsAcctServerSetup(2) tacacsAcctServerTable(2) tacacsAcctServerEntry(1) tacacsAcctServerIpAddr(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55c(48) tacacsServerSetup(58) tacacsAcctServerSetup(2) tacacsAcctServerTable(2) tacacsAcctServerEntry(1) tacacsAcctServerIpAddr(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55C(48) tacacsServerSetup(58) tacacsAcctServerSetup(2) tacacsAcctServerTable(2) tacacsAcctServerEntry(1) tacacsAcctServerIpAddr(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55c(48) tacacsServerSetup(58) tacacsAcctServerSetup(2) tacacsAcctServerTable(2) tacacsAcctServerEntry(1) tacacsAcctServerIpAddr(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55C(48) tacacsServerSetup(58) tacacsAcctServerSetup(2) tacacsAcctServerTable(2) tacacsAcctServerEntry(1) tacacsAcctServerIpAddr(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55c(48) tacacsServerSetup(58) tacacsAcctServerSetup(2) tacacsAcctServerTable(2) tacacsAcctServerEntry(1) tacacsAcctServerIpAddr(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55C(48) tacacsServerSetup(58) tacacsAcctServerSetup(2) tacacsAcctServerTable(2) tacacsAcctServerEntry(1) tacacsAcctServerIpAddr(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55c(48) tacacsServerSetup(58) tacacsAcctServerSetup(2) tacacsAcctServerTable(2) tacacsAcctServerEntry(1) tacacsAcctServerIpAddr(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55C(48) tacacsServerSetup(58) tacacsAcctServerSetup(2) tacacsAcctServerTable(2) tacacsAcctServerEntry(1) tacacsAcctServerIpAddr(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55c(48) tacacsServerSetup(58) tacacsAcctServerSetup(2) tacacsAcctServerTable(2) tacacsAcctServerEntry(1) tacacsAcctServerIpAddr(2)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/890/1/5/12/48/58/2/2/1/2
  • /ISO/Identified-Organization/6/1/4/1/890/1/5/12/48/58/2/2/1/2
  • /ISO/3/6/1/4/1/890/1/5/12/48/58/2/2/1/2
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/thermalSensorFailure/ves1724-55C/tacacsServerSetup/tacacsAcctServerSetup/tacacsAcctServerTable/tacacsAcctServerEntry/tacacsAcctServerIpAddr
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/thermalSensorFailure/ves1724-55c/tacacsServerSetup/tacacsAcctServerSetup/tacacsAcctServerTable/tacacsAcctServerEntry/tacacsAcctServerIpAddr
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/vesSeries/ves1724-55C/tacacsServerSetup/tacacsAcctServerSetup/tacacsAcctServerTable/tacacsAcctServerEntry/tacacsAcctServerIpAddr
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/vesSeries/ves1724-55c/tacacsServerSetup/tacacsAcctServerSetup/tacacsAcctServerTable/tacacsAcctServerEntry/tacacsAcctServerIpAddr
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/thermalSensorFailure/ves1724-55C/tacacsServerSetup/tacacsAcctServerSetup/tacacsAcctServerTable/tacacsAcctServerEntry/tacacsAcctServerIpAddr
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/thermalSensorFailure/ves1724-55c/tacacsServerSetup/tacacsAcctServerSetup/tacacsAcctServerTable/tacacsAcctServerEntry/tacacsAcctServerIpAddr
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/vesSeries/ves1724-55C/tacacsServerSetup/tacacsAcctServerSetup/tacacsAcctServerTable/tacacsAcctServerEntry/tacacsAcctServerIpAddr
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/vesSeries/ves1724-55c/tacacsServerSetup/tacacsAcctServerSetup/tacacsAcctServerTable/tacacsAcctServerEntry/tacacsAcctServerIpAddr
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/thermalSensorFailure/ves1724-55C/tacacsServerSetup/tacacsAcctServerSetup/tacacsAcctServerTable/tacacsAcctServerEntry/tacacsAcctServerIpAddr
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/thermalSensorFailure/ves1724-55c/tacacsServerSetup/tacacsAcctServerSetup/tacacsAcctServerTable/tacacsAcctServerEntry/tacacsAcctServerIpAddr
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/vesSeries/ves1724-55C/tacacsServerSetup/tacacsAcctServerSetup/tacacsAcctServerTable/tacacsAcctServerEntry/tacacsAcctServerIpAddr
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/vesSeries/ves1724-55c/tacacsServerSetup/tacacsAcctServerSetup/tacacsAcctServerTable/tacacsAcctServerEntry/tacacsAcctServerIpAddr
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/thermalSensorFailure/ves1724-55C/tacacsServerSetup/tacacsAcctServerSetup/tacacsAcctServerTable/tacacsAcctServerEntry/tacacsAcctServerIpAddr
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/thermalSensorFailure/ves1724-55c/tacacsServerSetup/tacacsAcctServerSetup/tacacsAcctServerTable/tacacsAcctServerEntry/tacacsAcctServerIpAddr
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/vesSeries/ves1724-55C/tacacsServerSetup/tacacsAcctServerSetup/tacacsAcctServerTable/tacacsAcctServerEntry/tacacsAcctServerIpAddr
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/vesSeries/ves1724-55c/tacacsServerSetup/tacacsAcctServerSetup/tacacsAcctServerTable/tacacsAcctServerEntry/tacacsAcctServerIpAddr
  • Additional combinations skipped.

SNMP properties

Value type
IpAddress
Maximum access defined by MIB
read-write
Status in MIB
current

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In ZYXEL-ves1724-55c-MIB, the row index tacacsAcctServerIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.890.1.5.12.48.58.2.2.1.2.<tacacsAcctServerIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.890.1.5.12.48.58.2.2.1.2

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Product context

Documented MIB packages

The Zyxel catalogue lists MIB packages containing this definition for these models:

VES1724-55C.

A definition in a model's MIB package does not establish that the device implements it or permits access.

The displayed source records contain one distinct definition. Compare its source records.

tacacsAcctServerIpAddr OBJECT-TYPE
        SYNTAX  IpAddress
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
                     	"IPv4 only"
        ::= { tacacsAcctServerEntry 2 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Zyxel official Download Library MIBs1 record · 1 source

Description 1

tacacsAcctServerIpAddr · currentZyxel official Download Library MIBs1 source

Status in source: current.

Names: tacacsAcctServerIpAddr

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "tacacsAcctServerIpAddr",
    "OBJECT-TYPE",
    "SYNTAX",
    "IpAddress",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"IPv4 only\"",
    "::=",
    "{",
    "tacacsAcctServerEntry",
    "2",
    "}"
  ],
  "syntax_tree": [
    [
      "ApplicationSyntax",
      "IpAddress",
      null
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "IPv4 only"
    ],
    null,
    null,
    null,
    null
  ]
}
  • Zyxel official Download Library MIBs · Publisher's source file: VES1724-55C_2.mib

    Module: ZYXEL-ves1724-55c-MIB

    See published definition above

    Module imports
    {'IF-MIB': ['InterfaceIndexOrZero', 'ifIndex'], 'IPV6-TC': ['Ipv6Address', 'Ipv6AddressPrefix'], 'SNMPv2-TC': ['RowStatus', 'DateAndTime', 'TruthValue', 'StorageType', 'MacAddress'], 'BRIDGE-MIB': ['dot1dBasePort', 'BridgeId', 'Timeout'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'IpAddress', 'NOTIFICATION-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString', 'sysObjectID'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList', 'dot1qVlanIndex'], 'VDSL-LINE-MIB': ['vdslLineConfProfileName', 'vdslLineAlarmConfProfileName', 'vdslPerf1DayIntervalNumber', 'vdslPhysSide', 'vdslPerfIntervalNumber'], 'VDSL2-LINE-MIB': ['xdsl2PMChHist1DInterval', 'xdsl2LineBand', 'xdsl2SCStatusSegment', 'xdsl2LineSegmentDirection', 'xdsl2LineSegment', 'xdsl2ChStatusUnit', 'xdsl2SCStatusDirection', 'xdsl2SCStatusBand', 'xdsl2PMLHist15MUnit', 'xdsl2PMLHist15MInterval', 'xdsl2PMLHist1DUnit', 'xdsl2PMLHist1DInterval', 'xdsl2PMChCurrUnit', 'xdsl2PMChHist15MUnit', 'xdsl2PMChHist15MInterval', 'xdsl2PMLCurrUnit', 'xdsl2PMChHist1DUnit', 'xdsl2LConfTempTemplateName', 'xdsl2LConfProfProfileName', 'xdsl2ChConfProfProfileName', 'xdsl2LAlarmConfTempTemplateName', 'xdsl2LineAlarmConfProfileName', 'xdsl2ChAlarmConfProfileName'], 'DISMAN-PING-MIB': ['OperationResponseStatus'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'VDSL2-LINE-TC-MIB': ['Xdsl2RaMode', 'Xdsl2LineLdsf'], 'HC-PerfHist-TC-MIB': ['HCPerfIntervalThreshold', 'HCPerfTimeElapsed'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download VES1724-55C_2.mib

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.890)

Harry Chou

Siblings (5)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.890.1.5.12.48.58.2.2.1.1 tacacsAcctServerIndex00
1.3.6.1.4.1.890.1.5.12.48.58.2.2.1.3 tacacsAcctServerTcpPort00
1.3.6.1.4.1.890.1.5.12.48.58.2.2.1.4 tacacsAcctServerSharedSecret00
1.3.6.1.4.1.890.1.5.12.48.58.2.2.1.5 tacacsAcctServerIpAddressType00
1.3.6.1.4.1.890.1.5.12.48.58.2.2.1.6 tacacsAcctServerIpAddress00