OID reference

batterySaving

1.3.6.1.4.1.890.1.5.12.49.5.7

Description

Each bit corresponds to a method. BIT 1: input1 BIT 2: input2 BIT 3: input3 BIT 4: input4

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.890.1.5.12.49.5 (hwmonitor)
Node code
7
Node name
batterySaving
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.890.1.5.12.49.5.7
URN notation
urn:oid:1.3.6.1.4.1.890.1.5.12.49.5.7
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 890 1 5 12 49 5 7}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-58V(49) hwmonitor(5) batterySaving(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-58v(49) hwmonitor(5) batterySaving(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-58V(49) hwmonitor(5) batterySaving(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-58v(49) hwmonitor(5) batterySaving(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-58V(49) hwmonitor(5) batterySaving(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-58v(49) hwmonitor(5) batterySaving(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-58V(49) hwmonitor(5) batterySaving(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-58v(49) hwmonitor(5) batterySaving(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-58V(49) hwmonitor(5) batterySaving(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-58v(49) hwmonitor(5) batterySaving(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-58V(49) hwmonitor(5) batterySaving(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-58v(49) hwmonitor(5) batterySaving(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-58V(49) hwmonitor(5) batterySaving(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-58v(49) hwmonitor(5) batterySaving(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-58V(49) hwmonitor(5) batterySaving(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-58v(49) hwmonitor(5) batterySaving(7)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/890/1/5/12/49/5/7
  • /ISO/Identified-Organization/6/1/4/1/890/1/5/12/49/5/7
  • /ISO/3/6/1/4/1/890/1/5/12/49/5/7
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/thermalSensorFailure/ves1724-58V/hwmonitor/batterySaving
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/thermalSensorFailure/ves1724-58v/hwmonitor/batterySaving
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/vesSeries/ves1724-58V/hwmonitor/batterySaving
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/vesSeries/ves1724-58v/hwmonitor/batterySaving
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/thermalSensorFailure/ves1724-58V/hwmonitor/batterySaving
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/thermalSensorFailure/ves1724-58v/hwmonitor/batterySaving
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/vesSeries/ves1724-58V/hwmonitor/batterySaving
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/vesSeries/ves1724-58v/hwmonitor/batterySaving
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/thermalSensorFailure/ves1724-58V/hwmonitor/batterySaving
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/thermalSensorFailure/ves1724-58v/hwmonitor/batterySaving
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/vesSeries/ves1724-58V/hwmonitor/batterySaving
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/vesSeries/ves1724-58v/hwmonitor/batterySaving
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/thermalSensorFailure/ves1724-58V/hwmonitor/batterySaving
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/thermalSensorFailure/ves1724-58v/hwmonitor/batterySaving
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/vesSeries/ves1724-58V/hwmonitor/batterySaving
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/vesSeries/ves1724-58v/hwmonitor/batterySaving
  • Additional combinations skipped.

SNMP properties

Value type
BITS
Maximum access defined by MIB
read-write
Status in MIB
current

Bit values

Bit positionName
0input1
1input2
2input3
3input4

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.890.1.5.12.49.5.7.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

batterySaving OBJECT-TYPE
    SYNTAX BITS {          
          input1(0),
          input2(1),
          input3(2),
	      input4(3)
    }
	MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
	" Each bit corresponds to a method.
	BIT 1: input1
	BIT 2: input2
	BIT 3: input3
	BIT 4: input4
	"
       ::= { hwmonitor 7 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Each bit corresponds to a method. BIT 1: input1 BIT 2: input2 BIT 3: input3 BIT 4: input4

Sources for this description

Zyxel MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Zyxel MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

batterySaving · currentZyxel MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: batterySaving

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "batterySaving",
    "OBJECT-TYPE",
    "SYNTAX",
    "BITS",
    "{",
    "input1",
    "(",
    "0",
    ")",
    ",",
    "input2",
    "(",
    "1",
    ")",
    ",",
    "input3",
    "(",
    "2",
    ")",
    ",",
    "input4",
    "(",
    "3",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\" Each bit corresponds to a method. BIT 1: input1 BIT 2: input2 BIT 3: input3 BIT 4: input4 \"",
    "::=",
    "{",
    "hwmonitor",
    "7",
    "}"
  ],
  "syntax_tree": [
    [
      "BITS",
      [
        [
          "input1",
          0
        ],
        [
          "input2",
          1
        ],
        [
          "input3",
          2
        ],
        [
          "input4",
          3
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Each bit corresponds to a method. BIT 1: input1 BIT 2: input2 BIT 3: input3 BIT 4: input4"
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.890)

Harry Chou

Siblings (7)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.890.1.5.12.49.5.1 fanConfTable14
1.3.6.1.4.1.890.1.5.12.49.5.2 temperatureConfTable14
1.3.6.1.4.1.890.1.5.12.49.5.3 voltageConfTable14
1.3.6.1.4.1.890.1.5.12.49.5.4 fanStatsTable16
1.3.6.1.4.1.890.1.5.12.49.5.5 temperatureStatsTable16
1.3.6.1.4.1.890.1.5.12.49.5.6 voltageStatsTable17
1.3.6.1.4.1.890.1.5.12.49.5.8 externalBattery29