Status in source: current.
Names: sysRestartProbableCause
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"sysRestartProbableCause",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"The variable describes the probable cause that caused system restart. Below probable cause shall be implemented accordingly. sysResetCause is '1' (hardware related) and if sysRestartErrorCode is 1: power input missing - powerProblem (58) 2: hardware watchdog triggered - processorProblems (535) 3: overheat triggered - highTemperature (123) 4: maintenance button pressed > 8 seconds - maunal (1025) sysResetCause is '2' (software related) and if sysRestartCode is 1: triggered by software watchdog - softwareProgramError (546) 2: restart caused by program exception (additional context stored for reference) - softwareError (163) 3: restart caused by software program intentionally - softwareError (163). sysResetCause is '3' (operation related) and if sysRestartErrorCode is 1: operator press maintenance button 7 seconds - maintenance (1026) 2: operator reset manually (either by SNMP or CLI command) - manual (1025) 3: firmware upgrade - sfwrDownloadFailure (156)\"",
"::=",
"{",
"object",
"25",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The variable describes the probable cause that caused system restart. Below probable cause shall be implemented accordingly. sysResetCause is '1' (hardware related) and if sysRestartErrorCode is 1: power input missing - powerProblem (58) 2: hardware watchdog triggered - processorProblems (535) 3: overheat triggered - highTemperature (123) 4: maintenance button pressed > 8 seconds - maunal (1025) sysResetCause is '2' (software related) and if sysRestartCode is 1: triggered by software watchdog - softwareProgramError (546) 2: restart caused by program exception (additional context stored for reference) - softwareError (163) 3: restart caused by software program intentionally - softwareError (163). sysResetCause is '3' (operation related) and if sysRestartErrorCode is 1: operator press maintenance button 7 seconds - maintenance (1026) 2: operator reset manually (either by SNMP or CLI command) - manual (1025) 3: firmware upgrade - sfwrDownloadFailure (156)"
],
null,
null,
null,
null
]
}
- Zyxel MIB copies (LibreNMS/Observium Community)
· Publisher's source file: IES5206-TRAPS-MIB
Vendor MIB copy from the LibreNMS archive.
Zyxel support.
Module: IES5206-TRAPS-MIB
See published definition above
Module imports
{'IF-MIB': ['ifAdminStatus', 'ifOperStatus'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'IpAddress', 'Unsigned32', 'NOTIFICATION-TYPE'], 'IES5206-MIB': ['ies5206', 'slotModuleId', 'voltageConfIndex', 'voltageCurValue', 'temperatureConfIndex', 'temperatureCurValue', 'coaConfIssueThreshold', 'coaConfAnalyticMethod', 'sysFwUpgradeStatus', 'sysBootupFwVersion', 'transceiverDdmInfoEntryType', 'transceiverDdmInfoEntryAlarmMax', 'transceiverDdmInfoEntryAlarmMin', 'transceiverDdmInfoEntryWarnMax', 'transceiverDdmInfoEntryWarnMin', 'transceiverDdmInfoEntryCurrent', 'transceiverPerOntRxPower'], 'RFC1213-MIB': ['DisplayString', 'ifIndex'], 'IANA-ITU-ALARM-TC-MIB': ['IANAItuProbableCause', 'IANAItuEventType']}
· Download IES5206-TRAPS-MIB
Related source files and packages:
Same file in Observium Community.