OID reference

voltageConfCardType

1.3.6.1.4.1.890.1.5.13.13.5.3.1.4

Description

Card type of Voltage threshold

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.890.1.5.13.13.5.3.1 (voltageConfEntry)
Node code
4
Node name
voltageConfCardType
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.890.1.5.13.13.5.3.1.4
URN notation
urn:oid:1.3.6.1.4.1.890.1.5.13.13.5.3.1.4
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 890 1 5 13 13 5 3 1 4}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) iesSeries(13) moduleDown(13) hwmonitor(5) voltageConfTable(3) voltageConfEntry(1) voltageConfCardType(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) iesSeries(13) ies5206(13) hwmonitor(5) voltageConfTable(3) voltageConfEntry(1) voltageConfCardType(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) ies2000(13) moduleDown(13) hwmonitor(5) voltageConfTable(3) voltageConfEntry(1) voltageConfCardType(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) ies2000(13) ies5206(13) hwmonitor(5) voltageConfTable(3) voltageConfEntry(1) voltageConfCardType(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) iesSeries(13) moduleDown(13) hwmonitor(5) voltageConfTable(3) voltageConfEntry(1) voltageConfCardType(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) iesSeries(13) ies5206(13) hwmonitor(5) voltageConfTable(3) voltageConfEntry(1) voltageConfCardType(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) ies2000(13) moduleDown(13) hwmonitor(5) voltageConfTable(3) voltageConfEntry(1) voltageConfCardType(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) ies2000(13) ies5206(13) hwmonitor(5) voltageConfTable(3) voltageConfEntry(1) voltageConfCardType(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) iesSeries(13) moduleDown(13) hwmonitor(5) voltageConfTable(3) voltageConfEntry(1) voltageConfCardType(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) iesSeries(13) ies5206(13) hwmonitor(5) voltageConfTable(3) voltageConfEntry(1) voltageConfCardType(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) ies2000(13) moduleDown(13) hwmonitor(5) voltageConfTable(3) voltageConfEntry(1) voltageConfCardType(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) ies2000(13) ies5206(13) hwmonitor(5) voltageConfTable(3) voltageConfEntry(1) voltageConfCardType(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) iesSeries(13) moduleDown(13) hwmonitor(5) voltageConfTable(3) voltageConfEntry(1) voltageConfCardType(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) iesSeries(13) ies5206(13) hwmonitor(5) voltageConfTable(3) voltageConfEntry(1) voltageConfCardType(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) ies2000(13) moduleDown(13) hwmonitor(5) voltageConfTable(3) voltageConfEntry(1) voltageConfCardType(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) ies2000(13) ies5206(13) hwmonitor(5) voltageConfTable(3) voltageConfEntry(1) voltageConfCardType(4)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/890/1/5/13/13/5/3/1/4
  • /ISO/Identified-Organization/6/1/4/1/890/1/5/13/13/5/3/1/4
  • /ISO/3/6/1/4/1/890/1/5/13/13/5/3/1/4
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/iesSeries/moduleDown/hwmonitor/voltageConfTable/voltageConfEntry/voltageConfCardType
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/iesSeries/ies5206/hwmonitor/voltageConfTable/voltageConfEntry/voltageConfCardType
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/ies2000/moduleDown/hwmonitor/voltageConfTable/voltageConfEntry/voltageConfCardType
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/ies2000/ies5206/hwmonitor/voltageConfTable/voltageConfEntry/voltageConfCardType
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/iesSeries/moduleDown/hwmonitor/voltageConfTable/voltageConfEntry/voltageConfCardType
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/iesSeries/ies5206/hwmonitor/voltageConfTable/voltageConfEntry/voltageConfCardType
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/ies2000/moduleDown/hwmonitor/voltageConfTable/voltageConfEntry/voltageConfCardType
  • /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/ies2000/ies5206/hwmonitor/voltageConfTable/voltageConfEntry/voltageConfCardType
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/iesSeries/moduleDown/hwmonitor/voltageConfTable/voltageConfEntry/voltageConfCardType
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/iesSeries/ies5206/hwmonitor/voltageConfTable/voltageConfEntry/voltageConfCardType
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/ies2000/moduleDown/hwmonitor/voltageConfTable/voltageConfEntry/voltageConfCardType
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/ies2000/ies5206/hwmonitor/voltageConfTable/voltageConfEntry/voltageConfCardType
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/iesSeries/moduleDown/hwmonitor/voltageConfTable/voltageConfEntry/voltageConfCardType
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/iesSeries/ies5206/hwmonitor/voltageConfTable/voltageConfEntry/voltageConfCardType
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/ies2000/moduleDown/hwmonitor/voltageConfTable/voltageConfEntry/voltageConfCardType
  • /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/ies2000/ies5206/hwmonitor/voltageConfTable/voltageConfEntry/voltageConfCardType
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current

Enumerated values

ValueName
0empty
1unknown
11msc1240xa
12msc1240xb
13msc1240xc
14msc1280xa
15msc1240qa
16msc1280x
21vec1001x
22vec1002x
23oul3540x
31vlc1448x-51
32vlc1448x-53
33vlc1448x-51s
34vlc1448x-51c
41olc3416-22
42olc3416-42
51glc1440x-55
52glc1440x-55a

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In IES5206-MIB, the row index consists of these components in order:

  1. slotModuleId (INTEGER): one numeric subidentifier for the non-negative value.
  2. voltageConfIndex (INTEGER): one numeric subidentifier for the non-negative value.

An instance has the form .1.3.6.1.4.1.890.1.5.13.13.5.3.1.4.<slotModuleId>.<voltageConfIndex>. Use values present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.890.1.5.13.13.5.3.1.4

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

voltageConfCardType OBJECT-TYPE
	SYNTAX INTEGER {
		empty(0),
		unknown(1),
		msc1240xa(11),
		msc1240xb(12),
		msc1240xc(13),
		msc1280xa(14),
		msc1240qa(15),
		msc1280x(16),
		vec1001x(21),
		vec1002x(22),
		oul3540x(23),
		vlc1448x-51(31),
		vlc1448x-53(32),
		vlc1448x-51s(33),
		vlc1448x-51c(34),
		olc3416-22(41),
		olc3416-42(42),
		glc1440x-55(51),
		glc1440x-55a(52)
	}
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
		"Card type of Voltage threshold"

	::= { voltageConfEntry 4 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Zyxel MIB copies (LibreNMS/Observium Community)1 record · 2 sources

Description 1

voltageConfCardType · currentZyxel MIB copies (LibreNMS/Observium Community)2 sources

Status in source: current.

Names: voltageConfCardType

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "voltageConfCardType",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "empty",
    "(",
    "0",
    ")",
    ",",
    "unknown",
    "(",
    "1",
    ")",
    ",",
    "msc1240xa",
    "(",
    "11",
    ")",
    ",",
    "msc1240xb",
    "(",
    "12",
    ")",
    ",",
    "msc1240xc",
    "(",
    "13",
    ")",
    ",",
    "msc1280xa",
    "(",
    "14",
    ")",
    ",",
    "msc1240qa",
    "(",
    "15",
    ")",
    ",",
    "msc1280x",
    "(",
    "16",
    ")",
    ",",
    "vec1001x",
    "(",
    "21",
    ")",
    ",",
    "vec1002x",
    "(",
    "22",
    ")",
    ",",
    "oul3540x",
    "(",
    "23",
    ")",
    ",",
    "vlc1448x-51",
    "(",
    "31",
    ")",
    ",",
    "vlc1448x-53",
    "(",
    "32",
    ")",
    ",",
    "vlc1448x-51s",
    "(",
    "33",
    ")",
    ",",
    "vlc1448x-51c",
    "(",
    "34",
    ")",
    ",",
    "olc3416-22",
    "(",
    "41",
    ")",
    ",",
    "olc3416-42",
    "(",
    "42",
    ")",
    ",",
    "glc1440x-55",
    "(",
    "51",
    ")",
    ",",
    "glc1440x-55a",
    "(",
    "52",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Card type of Voltage threshold\"",
    "::=",
    "{",
    "voltageConfEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "empty",
            0
          ],
          [
            "unknown",
            1
          ],
          [
            "msc1240xa",
            11
          ],
          [
            "msc1240xb",
            12
          ],
          [
            "msc1240xc",
            13
          ],
          [
            "msc1280xa",
            14
          ],
          [
            "msc1240qa",
            15
          ],
          [
            "msc1280x",
            16
          ],
          [
            "vec1001x",
            21
          ],
          [
            "vec1002x",
            22
          ],
          [
            "oul3540x",
            23
          ],
          [
            "vlc1448x-51",
            31
          ],
          [
            "vlc1448x-53",
            32
          ],
          [
            "vlc1448x-51s",
            33
          ],
          [
            "vlc1448x-51c",
            34
          ],
          [
            "olc3416-22",
            41
          ],
          [
            "olc3416-42",
            42
          ],
          [
            "glc1440x-55",
            51
          ],
          [
            "glc1440x-55a",
            52
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Card type of Voltage threshold"
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.890)

Harry Chou

Siblings (3)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.890.1.5.13.13.5.3.1.1 voltageConfIndex00
1.3.6.1.4.1.890.1.5.13.13.5.3.1.2 voltageConfHighThreshold00
1.3.6.1.4.1.890.1.5.13.13.5.3.1.3 voltageConfLowThreshold00