spanning tree msti instance number.
Sources for this description
Zyxel MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.890.1.5.13.5.12.1.33
spanning tree msti instance number.
Identification
{1 3 6 1 4 1 890 1 5 13 5 12 1 33}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.890.1.5.13.5.12.1.33.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
eqptSptMstiInstanceId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"spanning tree msti instance number."
::= { object 33 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
spanning tree msti instance number.
Zyxel MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: eqptSptMstiInstanceId
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"eqptSptMstiInstanceId",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"spanning tree msti instance number.\"",
"::=",
"{",
"object",
"33",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"spanning tree msti instance number."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive. Zyxel support.
Module: ZYXEL-IES5000-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex'], 'SNMPv2-TC': ['RowStatus', 'TEXTUAL-CONVENTION'], 'BRIDGE-MIB': ['MacAddress', 'Timeout', 'BridgeId', 'dot1dBasePort'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'Counter64', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'IpAddress', 'NOTIFICATION-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString', 'PhysAddress', 'ifIndex'], 'P-BRIDGE-MIB': ['dot1dTrafficClass', 'EnabledStatus'], 'Q-BRIDGE-MIB': ['VlanIndex', 'PortList', 'dot1qVlanIndex'], 'VDSL-LINE-MIB': ['vdslPhysSide', 'vdslChanCurrTxRate', 'vdslLineConfProfileName', 'vdslLineAlarmConfProfileName'], 'VDSL2-LINE-MIB': ['xdsl2PMChHist15MUnit', 'xdsl2PMChHist15MInterval', 'xdsl2PMLHist1DUnit', 'xdsl2PMLHist1DInterval', 'xdsl2PMLHist15MUnit', 'xdsl2PMLHist15MInterval', 'xdsl2PMChHist1DUnit', 'xdsl2PMChHist1DInterval', 'xdsl2PMLCurrUnit', 'xdsl2LConfProfProfileName', 'xdsl2ChConfProfProfileName', 'xdsl2LineAlarmConfProfileName', 'xdsl2LineBand', 'xdsl2LConfTempTemplateName', 'xdsl2LAlarmConfTempTemplateName', 'xdsl2ChAlarmConfProfileName', 'xdsl2SCStatusDirection', 'xdsl2SCStatusBand'], 'IEEE8021-CFM-MIB': ['dot1agCfmMdIndex', 'dot1agCfmMaIndex', 'dot1agCfmMepIdentifier', 'dot1agCfmMdMdLevel', 'dot1agCfmVlanPrimaryVid', 'dot1agCfmMepIdentifier'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress']}Related source files and packages:
Same file in Observium Community.
Registration