Status in source: current.
Names: adslPortOps
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"adslPortOps",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The managed object is for ADSL line configuration. When the EMS wants to issue the desired operation, the EMS shall send SNMP-SET message to set the corresponding bit value to be 1. The various bit positions are: BIT 1: enable port BIT 2: disable port BIT 3: set ADSL mode BIT 4: set line profile BIT 5: set alarm profile BIT 6: enable Annex L to be narrow mode(Only in AnnexA) BIT 7: enable Annex L to be wide mode(Only in AnnexA) BIT 8: disable Annex L(Only in AnnexA) BIT 9: enable Annex M (For BCM AnnexA solution) BIT 10: disable Annex M (For BCM AnnexA solution) BIT 11: enable Annex I (For BCM AnnexA solution) BIT 12: disable Annex I (For BCM AnnexA solution) BIT 13: set option mask BIT 14: enable power management mode to be L2 BIT 15: enable power management mode to be L3 BIT 16: disable power management mode BIT 17: set power mode to be fixed BIT 18: set power mode to be priority to power BIT 19: set power mode to be priority to rate BIT 20: set ATU-R max Tx power BIT 21: set ATU-C max Tx power BIT 22: set max Rx power BIT 23: set ATU-R carrier mask BIT 24: set ATU-C carrier mask BIT 25: set ATU-R INP minimum setting BIT 26: set ATU-C INP minimum setting\"",
"::=",
"{",
"adslPortBatchSet",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The managed object is for ADSL line configuration. When the EMS wants to issue the desired operation, the EMS shall send SNMP-SET message to set the corresponding bit value to be 1. The various bit positions are: BIT 1: enable port BIT 2: disable port BIT 3: set ADSL mode BIT 4: set line profile BIT 5: set alarm profile BIT 6: enable Annex L to be narrow mode(Only in AnnexA) BIT 7: enable Annex L to be wide mode(Only in AnnexA) BIT 8: disable Annex L(Only in AnnexA) BIT 9: enable Annex M (For BCM AnnexA solution) BIT 10: disable Annex M (For BCM AnnexA solution) BIT 11: enable Annex I (For BCM AnnexA solution) BIT 12: disable Annex I (For BCM AnnexA solution) BIT 13: set option mask BIT 14: enable power management mode to be L2 BIT 15: enable power management mode to be L3 BIT 16: disable power management mode BIT 17: set power mode to be fixed BIT 18: set power mode to be priority to power BIT 19: set power mode to be priority to rate BIT 20: set ATU-R max Tx power BIT 21: set ATU-C max Tx power BIT 22: set max Rx power BIT 23: set ATU-R carrier mask BIT 24: set ATU-C carrier mask BIT 25: set ATU-R INP minimum setting BIT 26: set ATU-C INP minimum setting"
],
null,
null,
null,
null
]
}