The UDP port for sflow collector entry. The range of UDP port is between 1 and 65535.
Sources for this description
Zyxel MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.890.1.5.8.75.123.2.1.3
The UDP port for sflow collector entry. The range of UDP port is between 1 and 65535.
Identification
{1 3 6 1 4 1 890 1 5 8 75 123 2 1 3}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: sFlowCollectorAddressType, sFlowCollectorAddress.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.890.1.5.8.75.123.2.1.3
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
sFlowCollectorUdpPort OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP port for sflow collector entry. The range of UDP port is between 1 and 65535."
::= { sFlowCollectorEntry 3 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The UDP port for sflow collector entry. The range of UDP port is between 1 and 65535.
Zyxel MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: sFlowCollectorUdpPort
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"sFlowCollectorUdpPort",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"1",
".",
".",
"65535",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The UDP port for sflow collector entry. The range of UDP port is between 1 and 65535.\"",
"::=",
"{",
"sFlowCollectorEntry",
"3",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
1,
65535
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The UDP port for sflow collector entry. The range of UDP port is between 1 and 65535."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Zyxel support.
Module: ZYXEL-MGS370012C-MIB
See published definition above
{'IF-MIB': ['InterfaceIndexOrZero', 'ifIndex'], 'SNMPv2-TC': ['RowStatus', 'DateAndTime', 'TruthValue', 'StorageType', 'MacAddress', 'TDomain', 'TAddress'], 'BRIDGE-MIB': ['dot1dBasePort', 'BridgeId', 'Timeout'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'Integer32', 'Counter32', 'Unsigned32', 'Counter64', 'IpAddress', 'NOTIFICATION-TYPE'], 'RFC1155-SMI': ['enterprises', 'Counter', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysObjectID'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList'], 'DISMAN-PING-MIB': ['OperationResponseStatus'], 'IEEE8021-CFM-MIB': ['dot1agCfmMdIndex', 'dot1agCfmMaIndex', 'dot1agCfmMepIdentifier'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.890.1.5.8.75.123.2.1.1 | sFlowCollectorAddressType | 0 | 0 | |
| 1.3.6.1.4.1.890.1.5.8.75.123.2.1.2 | sFlowCollectorAddress | 0 | 0 | |
| 1.3.6.1.4.1.890.1.5.8.75.123.2.1.4 | sFlowCollectorRowStatus | 0 | 0 |