OID reference

mrStackReset

1.3.6.1.4.1.9.2.11.1.1.5

Description

reset(1) noReset(2), A write to this object with reset(1) causes a complete reset of the repeater hardware and the Supervisor but does not run the POST. All FastHub configuration parameters are retained and all network related statistics in the system are cleared. Setting this object to noReset(2) has no effect. FastH…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.9.2.11.1.1 (mrStack)
Node code
5
Node name
mrStackReset
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.9.2.11.1.1.5
URN notation
urn:oid:1.3.6.1.4.1.9.2.11.1.1.5
Type
OBJECT-TYPE
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 9 2 11 1 1 5}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cisco(9) local(2) ciscoFastHubMIB(11) ciscoFastHubMIBObjects(1) mrStack(1) mrStackReset(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) me1200(9) local(2) ciscoFastHubMIB(11) ciscoFastHubMIBObjects(1) mrStack(1) mrStackReset(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cisco(9) local(2) ciscoFastHubMIB(11) ciscoFastHubMIBObjects(1) mrStack(1) mrStackReset(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) me1200(9) local(2) ciscoFastHubMIB(11) ciscoFastHubMIBObjects(1) mrStack(1) mrStackReset(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) cisco(9) local(2) ciscoFastHubMIB(11) ciscoFastHubMIBObjects(1) mrStack(1) mrStackReset(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) me1200(9) local(2) ciscoFastHubMIB(11) ciscoFastHubMIBObjects(1) mrStack(1) mrStackReset(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) cisco(9) local(2) ciscoFastHubMIB(11) ciscoFastHubMIBObjects(1) mrStack(1) mrStackReset(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) me1200(9) local(2) ciscoFastHubMIB(11) ciscoFastHubMIBObjects(1) mrStack(1) mrStackReset(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) cisco(9) local(2) ciscoFastHubMIB(11) ciscoFastHubMIBObjects(1) mrStack(1) mrStackReset(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) me1200(9) local(2) ciscoFastHubMIB(11) ciscoFastHubMIBObjects(1) mrStack(1) mrStackReset(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) cisco(9) local(2) ciscoFastHubMIB(11) ciscoFastHubMIBObjects(1) mrStack(1) mrStackReset(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) me1200(9) local(2) ciscoFastHubMIB(11) ciscoFastHubMIBObjects(1) mrStack(1) mrStackReset(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) cisco(9) local(2) ciscoFastHubMIB(11) ciscoFastHubMIBObjects(1) mrStack(1) mrStackReset(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) me1200(9) local(2) ciscoFastHubMIB(11) ciscoFastHubMIBObjects(1) mrStack(1) mrStackReset(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) cisco(9) local(2) ciscoFastHubMIB(11) ciscoFastHubMIBObjects(1) mrStack(1) mrStackReset(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) me1200(9) local(2) ciscoFastHubMIB(11) ciscoFastHubMIBObjects(1) mrStack(1) mrStackReset(5)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/9/2/11/1/1/5
  • /ISO/Identified-Organization/6/1/4/1/9/2/11/1/1/5
  • /ISO/3/6/1/4/1/9/2/11/1/1/5
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/cisco/local/ciscoFastHubMIB/ciscoFastHubMIBObjects/mrStack/mrStackReset
  • /iso/identified-organization/dod/internet/private/enterprise/me1200/local/ciscoFastHubMIB/ciscoFastHubMIBObjects/mrStack/mrStackReset
  • /iso/identified-organization/dod/internet/private/enterprise/Cisco/local/ciscoFastHubMIB/ciscoFastHubMIBObjects/mrStack/mrStackReset
  • /iso/identified-organization/dod/internet/private/enterprises/cisco/local/ciscoFastHubMIB/ciscoFastHubMIBObjects/mrStack/mrStackReset
  • /iso/identified-organization/dod/internet/private/enterprises/me1200/local/ciscoFastHubMIB/ciscoFastHubMIBObjects/mrStack/mrStackReset
  • /iso/identified-organization/dod/internet/private/enterprises/Cisco/local/ciscoFastHubMIB/ciscoFastHubMIBObjects/mrStack/mrStackReset
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/cisco/local/ciscoFastHubMIB/ciscoFastHubMIBObjects/mrStack/mrStackReset
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/me1200/local/ciscoFastHubMIB/ciscoFastHubMIBObjects/mrStack/mrStackReset
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Cisco/local/ciscoFastHubMIB/ciscoFastHubMIBObjects/mrStack/mrStackReset
  • /iso/identified-organization/dod/internet/private/vendor-objects/cisco/local/ciscoFastHubMIB/ciscoFastHubMIBObjects/mrStack/mrStackReset
  • /iso/identified-organization/dod/internet/private/vendor-objects/me1200/local/ciscoFastHubMIB/ciscoFastHubMIBObjects/mrStack/mrStackReset
  • /iso/identified-organization/dod/internet/private/vendor-objects/Cisco/local/ciscoFastHubMIB/ciscoFastHubMIBObjects/mrStack/mrStackReset
  • /iso/org/dod/internet/private/enterprise/cisco/local/ciscoFastHubMIB/ciscoFastHubMIBObjects/mrStack/mrStackReset
  • /iso/org/dod/internet/private/enterprise/me1200/local/ciscoFastHubMIB/ciscoFastHubMIBObjects/mrStack/mrStackReset
  • /iso/org/dod/internet/private/enterprise/Cisco/local/ciscoFastHubMIB/ciscoFastHubMIBObjects/mrStack/mrStackReset
  • /iso/org/dod/internet/private/enterprises/cisco/local/ciscoFastHubMIB/ciscoFastHubMIBObjects/mrStack/mrStackReset
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory

Enumerated values

ValueName
1reset
2noReset

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.9.2.11.1.1.5.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

mrStackReset · mandatory

mrStackReset OBJECT-TYPE
        SYNTAX  INTEGER { reset(1), noReset(2) }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "reset(1)       -- reset
                 noReset(2),    -- do nothing

                 A write to this object with reset(1) causes a complete
                 reset of the repeater hardware and the Supervisor but
                 does not run the POST. All FastHub configuration
                 parameters are retained and all network related statistics
                 in the system are cleared. Setting this object to
                 noReset(2) has no effect. FastHub will always return
                 noReset(2) when this object is read."

        ::= { mrStack 5 }

mrStackReset · mandatory

mrStackReset OBJECT-TYPE
        SYNTAX  INTEGER { reset(1), noReset(2) }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "reset(1)       -- reset
                 noReset(2),    -- do nothing

                 A write to this object with reset(1) causes a complete
                 reset of the repeater hardware and the Supervisor but
                 does not run the POST. All FastHub configuration
                 parameters are retained and all network related statistics
                 in the system are cleared. Setting this object to
                 noReset(2) has no effect. FastHub will always return
                 noReset(2) when this object is read."

        ::= { mrStack 5 }

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

reset(1)
noReset(2),

A write to this object with reset(1) causes a complete
reset of the repeater hardware and the Supervisor but
does not run the POST. All FastHub configuration
parameters are retained and all network related statistics
in the system are cleared. Setting this object to
noReset(2) has no effect. FastHub will always return
noReset(2) when this object is read.
Sources for this description

Circitor

Parsed from CISCO-FASTHUB-MIB.mib · CISCO-FASTHUB-MIB

Cisco SMIv1

MIBdepot

Description 2

reset(1) -- reset noReset(2), -- do nothing A write to this object with reset(1) causes a complete reset of the repeater hardware and the Supervisor but does not run the POST. All FastHub configuration parameters are retained and all network related statistics in the system are cleared. Setting this object to noReset(2) has no effect. FastHub will always return noReset(2) when this object is read.

Sources for this description

CircitorCisco MIB copies (LibreNMS/Observium Community)Cisco SMIv1MIBdepotNetdisco MIB archive copies

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 2Circitor, Cisco MIB copies (LibreNMS/Observium Community), and others1 record · 6 sources

Description 2

mrStackReset · mandatoryCircitor, Cisco MIB copies (LibreNMS/Observium Community), and others6 sources

Status in source: mandatory.

Names: mrStackReset

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "mrStackReset",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "reset",
    "(",
    "1",
    ")",
    ",",
    "noReset",
    "(",
    "2",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"reset(1) -- reset noReset(2), -- do nothing A write to this object with reset(1) causes a complete reset of the repeater hardware and the Supervisor but does not run the POST. All FastHub configuration parameters are retained and all network related statistics in the system are cleared. Setting this object to noReset(2) has no effect. FastHub will always return noReset(2) when this object is read.\"",
    "::=",
    "{",
    "mrStack",
    "5",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "reset",
            1
          ],
          [
            "noReset",
            2
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "reset(1) -- reset noReset(2), -- do nothing A write to this object with reset(1) causes a complete reset of the repeater hardware and the Supervisor but does not run the POST. All FastHub configuration parameters are retained and all network related statistics in the system are cleared. Setting this object to noReset(2) has no effect. FastHub will always return noReset(2) when this object is read."
    ],
    null,
    null,
    null,
    null
  ]
}

Historical records

Additional source information

Information from Cisco SMIv1
mrStackReset OBJECT-TYPE
        SYNTAX  INTEGER { reset(1), noReset(2) }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "reset(1)       
                 noReset(2),    

                 A write to this object with reset(1) causes a complete
                 reset of the repeater hardware and the Supervisor but
                 does not run the POST. All FastHub configuration
                 parameters are retained and all network related statistics
                 in the system are cleared. Setting this object to
                 noReset(2) has no effect. FastHub will always return
                 noReset(2) when this object is read."

        ::= { mrStack 5 }
Information from OID Repository
Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.
Information from MIBdepot
mrStackReset OBJECT-TYPE
        SYNTAX  INTEGER { reset(1), noReset(2) }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "reset(1)       
                 noReset(2),    

                 A write to this object with reset(1) causes a complete
                 reset of the repeater hardware and the Supervisor but
                 does not run the POST. All FastHub configuration
                 parameters are retained and all network related statistics
                 in the system are cleared. Setting this object to
                 noReset(2) has no effect. FastHub will always return
                 noReset(2) when this object is read."

        ::= { mrStack 5 }
Information from Circitor
mrStackReset OBJECT-TYPE
        SYNTAX  INTEGER { reset(1), noReset(2) }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "reset(1)       
                 noReset(2),    

                 A write to this object with reset(1) causes a complete
                 reset of the repeater hardware and the Supervisor but
                 does not run the POST. All FastHub configuration
                 parameters are retained and all network related statistics
                 in the system are cleared. Setting this object to
                 noReset(2) has no effect. FastHub will always return
                 noReset(2) when this object is read."

        ::= { mrStack 5 }

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.9)

Greg Satz

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.9)

Cisco Systems, Inc.

Direct children (1)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.9.2.11.1.1.5.0 mrStackReset00

Siblings (7)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.9.2.11.1.1.1 mrStackUnitCapacity11 This object returns the maximum number of repeater units
that can be stacked in the system and managed as one
repeater.
1.3.6.1.4.1.9.2.11.1.1.2 mrStackNumberOfUnitsPresent11 This object returns the current number of repeater units
in the stack.
1.3.6.1.4.1.9.2.11.1.1.3 mrStackSelectPrimarySupervisorUnit11 In a multi-unit FastHub stack with more than one Supervisor
management module installed, this object selects which
unit and hence…
1.3.6.1.4.1.9.2.11.1.1.4 mrStackPOSTSelect11 normal(1),
abbreviated(2)

This object configures the type of Supervisor Power On
Self Test FastHub will run upon power up. The nor…
1.3.6.1.4.1.9.2.11.1.1.6 mrStackDefaultReset11 reset(1)
noReset(2),

A write to this object with reset(1) causes a complete
reset of the repeater hardware and the Supervisor but …
1.3.6.1.4.1.9.2.11.1.1.7 mrStackClearStatistics11 clear(1)
noClear(2),

A write to this object with noClear(2) results in no
action. A write of clear(1) will cause FastHub to reset
a…
1.3.6.1.4.1.9.2.11.1.1.8 mrStackShortJabberLoopCorrections11