Status in source: current.
Names: rlCdpSecondaryCacheAddress
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rlCdpSecondaryCacheAddress",
"OBJECT-TYPE",
"SYNTAX",
"CiscoNetworkAddress",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"A network-layer address of the device as reported in the most recent CDP message's Address TLV. For example, if the the corresponding instance of rlCdpSecondaryCacheAddressType had the value 'ip(1)', then this object would be an IPv4-address.\"",
"::=",
"{",
"rlCdpSecondaryCacheAddressEntry",
"5",
"}"
],
"syntax_tree": [
[
"row",
"CiscoNetworkAddress"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"A network-layer address of the device as reported in the most recent CDP message's Address TLV. For example, if the the corresponding instance of rlCdpSecondaryCacheAddressType had the value 'ip(1)', then this object would be an IPv4-address."
],
null,
null,
null,
null
]
}
- Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Module: CISCOSB-CDP-MIB
See published definition above
Module imports
{'IF-MIB': ['InterfaceIndexOrZero', 'InterfaceIndex'], 'CISCO-TC': ['CiscoNetworkProtocol', 'CiscoNetworkAddress'], 'SNMPv2-TC': ['DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress', 'TruthValue'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'IpAddress', 'Unsigned32', 'MODULE-IDENTITY', 'Counter32'], 'CISCOSB-MIB': ['switch001'], 'Q-BRIDGE-MIB': ['PortList', 'VlanId'], 'CISCO-CDP-MIB': ['cdpCacheEntry', 'cdpCacheIfIndex', 'cdpCacheDeviceIndex'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'CISCOSB-TRAPS-MIB': ['rndNotifications'], 'CISCOSB-DEVICEPARAMS-MIB': ['rndErrorDesc', 'rndErrorSeverity']}
· Download CISCOSB-CDP-MIB
Related source files and packages:
- Cisco MIB copies (LibreNMS/Observium Community)
· Publisher's source file: CISCOSB-CDP-MIB
Vendor MIB copy from the LibreNMS archive.
Cisco support.
Module: CISCOSB-CDP-MIB
See published definition above
Module imports
{'IF-MIB': ['InterfaceIndexOrZero', 'InterfaceIndex'], 'CISCO-TC': ['CiscoNetworkProtocol', 'CiscoNetworkAddress'], 'SNMPv2-TC': ['DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress', 'TruthValue'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'IpAddress', 'Unsigned32', 'MODULE-IDENTITY', 'Counter32'], 'CISCOSB-MIB': ['switch001', 'rndNotifications'], 'Q-BRIDGE-MIB': ['PortList', 'VlanId'], 'CISCO-CDP-MIB': ['cdpCacheEntry', 'cdpCacheIfIndex', 'cdpCacheDeviceIndex'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'CISCOSB-DEVICEPARAMS-MIB': ['rndErrorDesc', 'rndErrorSeverity']}
· Download CISCOSB-CDP-MIB
Related source files and packages:
- Netdisco MIB archive copies
· Publisher's source file: CISCOSBCDP.mib
Vendor MIB copy from the Netdisco archive.
Module: CISCOSB-CDP-MIB
Same published definition
Module imports
{'IF-MIB': ['InterfaceIndexOrZero', 'InterfaceIndex'], 'CISCO-TC': ['CiscoNetworkProtocol', 'CiscoNetworkAddress'], 'SNMPv2-TC': ['DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress', 'TruthValue'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'IpAddress', 'Unsigned32', 'MODULE-IDENTITY', 'Counter32'], 'CISCOSB-MIB': ['switch001', 'rndNotifications'], 'Q-BRIDGE-MIB': ['PortList', 'VlanId'], 'CISCO-CDP-MIB': ['cdpCacheEntry', 'cdpCacheIfIndex', 'cdpCacheDeviceIndex'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'CISCOSB-DEVICEPARAMS-MIB': ['rndErrorDesc', 'rndErrorSeverity']}
· Download CISCOSBCDP.mib
Related source files and packages: