The compliance statement for devices that support sending system messages to a syslog collector.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
OID reference
1.3.6.1.4.1.9.6.1.101.82.1.4.2.1
The compliance statement for devices that support sending system messages to a syslog collector.
Identification
{1 3 6 1 4 1 9 6 1 101 82 1 4 2 1}
The displayed source records contain one distinct definition. Compare its source records.
snmpSyslogDeviceCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for devices that support sending
system messages to a syslog collector."
MODULE -- this module
MANDATORY-GROUPS {
snmpSyslogDeviceGroup,
snmpSyslogCollectorGroup,
snmpSyslogCollectorDefaultsGroup
}
GROUP snmpSyslogApplicationGroup
DESCRIPTION
"The snmpSyslogApplication group is mandatory only for
agents which support configuring the severity level of
the messages that individual applications may generate."
OBJECT snmpSyslogCollectorUdpPort
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required for implementations that
do not support configuring the UDP port number on a
per collector basis."
OBJECT snmpSyslogCollectorFacility
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required for implementations that
do not support configuring the syslog facility on a
per collector basis."
OBJECT snmpSyslogCollectorSeverity
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required for implementations that
do not support configuring the message severity level
on a per collector basis."
OBJECT snmpSyslogCollectorDefaultUdpPort
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required for implementations that
do not support configuring the UDP port number at all,
or do not want to support a configurable default.
Hopefully, it is only the later."
OBJECT snmpSyslogCollectorDefaultFacility
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required for implementations that
do not support configuring the syslog facility at all,
or do not want to support a configurable default.
Hopefully, it is only the later."
OBJECT snmpSyslogCollectorDefaultSeverity
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required for implementations that
do not support configuring the syslog facility at all,
or do not want to support a configurable default.
Hopefully, it is only the later."
::= { snmpSyslogDeviceCompliances 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The compliance statement for devices that support sending system messages to a syslog collector.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: snmpSyslogDeviceCompliance
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"snmpSyslogDeviceCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"The compliance statement for devices that support sending system messages to a syslog collector.\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"snmpSyslogDeviceGroup",
",",
"snmpSyslogCollectorGroup",
",",
"snmpSyslogCollectorDefaultsGroup",
"}",
"GROUP",
"snmpSyslogApplicationGroup",
"DESCRIPTION",
"\"The snmpSyslogApplication group is mandatory only for agents which support configuring the severity level of the messages that individual applications may generate.\"",
"OBJECT",
"snmpSyslogCollectorUdpPort",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required for implementations that do not support configuring the UDP port number on a per collector basis.\"",
"OBJECT",
"snmpSyslogCollectorFacility",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required for implementations that do not support configuring the syslog facility on a per collector basis.\"",
"OBJECT",
"snmpSyslogCollectorSeverity",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required for implementations that do not support configuring the message severity level on a per collector basis.\"",
"OBJECT",
"snmpSyslogCollectorDefaultUdpPort",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required for implementations that do not support configuring the UDP port number at all, or do not want to support a configurable default. Hopefully, it is only the later.\"",
"OBJECT",
"snmpSyslogCollectorDefaultFacility",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required for implementations that do not support configuring the syslog facility at all, or do not want to support a configurable default. Hopefully, it is only the later.\"",
"OBJECT",
"snmpSyslogCollectorDefaultSeverity",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required for implementations that do not support configuring the syslog facility at all, or do not want to support a configurable default. Hopefully, it is only the later.\"",
"::=",
"{",
"snmpSyslogDeviceCompliances",
"1",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"The compliance statement for devices that support sending system messages to a syslog collector."
],
null,
[
"ComplianceModules",
[
[
null,
[
"snmpSyslogDeviceGroup",
"snmpSyslogCollectorGroup",
"snmpSyslogCollectorDefaultsGroup",
"snmpSyslogApplicationGroup"
]
]
]
]
]
}Vendor MIB copy from the Observium Community archive.
Module: DRAFT-IETF-SYSLOG-DEVICE-MIB
See published definition above
{'SNMPv2-TC': ['RowStatus', 'TEXTUAL-CONVENTION', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter32', 'Gauge32', 'snmpModules'], 'CISCOSB-MIB': ['rlSyslog'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: CISCOSB-IETF-SYSLOG-DEVICE-MIB
{'SNMPv2-TC': ['RowStatus', 'TEXTUAL-CONVENTION', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter32', 'Gauge32', 'snmpModules'], 'CISCOSB-MIB': ['rlSyslog'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Vendor MIB copy from the Netdisco archive.
Module: DRAFT-IETF-SYSLOG-DEVICE-MIB
{'SNMPv2-TC': ['RowStatus', 'TEXTUAL-CONVENTION', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter32', 'Gauge32', 'snmpModules'], 'CISCOSB-MIB': ['rlSyslog'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Registration