Set to TRUE to start VeriPHy for the interface. When running 10 and 100 Mbps, ports will be linked down while running VeriPHY. Therefore, running VeriPHY on a 10 or 100 Mbps management port will cause the switch to stop responding until VeriPHY is complete.
Status in source: current.
Names: me1200PortVeriPhyStartStart
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"me1200PortVeriPhyStartStart",
"OBJECT-TYPE",
"SYNTAX",
"TruthValue",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Set to TRUE to start VeriPHy for the interface. When running 10 and 100 Mbps, ports will be linked down while running VeriPHY. Therefore, running VeriPHY on a 10 or 100 Mbps management port will cause the switch to stop responding until VeriPHY is complete.\"",
"::=",
"{",
"me1200PortVeriPhyStartEntry",
"2",
"}"
],
"syntax_tree": [
[
"row",
"TruthValue"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Set to TRUE to start VeriPHy for the interface. When running 10 and 100 Mbps, ports will be linked down while running VeriPHY. Therefore, running VeriPHY on a 10 or 100 Mbps management port will cause the switch to stop responding until VeriPHY is complete."
],
null,
null,
null,
null
]
}- cisco-products
· Publisher's source file
· Archived source file
· Official repository archive
Source location: ME1200-PORT-MIB::me1200PortVeriPhyStartStart.Source version and references
Published package: Cisco ME1200-MIBS 15.4_2_SN1; file: ME1200-MIBS/15.4_2_SN1/ME1200-PORT-MIB.mib.
Downloaded: 2026-10-21T03:34:10.732537+00:00. SHA-256:
d35f6d7cc5e31a6cf8296ee5e97c1c676641f08635f200e5ba91b2e1e33b4eda{'kind': 'OBJECT-TYPE', 'details': {'module': 'ME1200-PORT-MIB', 'imports': {'ME1200-TC': ['ME1200InterfaceIndex', 'ME1200DisplayString', 'ME1200Unsigned8'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'CISCOME1200-MIB': ['me1200SwitchMgmt']}, 'document': {'software': 'Cisco ME1200-MIBS', 'original_name': 'ME1200-MIBS/15.4_2_SN1/ME1200-PORT-MIB.mib', 'release_sha256': 'fdd5f5f181891a7352b13a73b80cbb24bb2c5ecb0d6d4fd22fc945100c43a009', 'release_version': '15.4_2_SN1'}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'me1200PortVeriPhyStartStart OBJECT-TYPE\n SYNTAX TruthValue\n MAX-ACCESS read-write\n STATUS current\n DESCRIPTION \n "Set to TRUE to start VeriPHy for the interface.\n \n When running 10 and 100 Mbps, ports will be linked down while running\n VeriPHY. Therefore, running VeriPHY on a 10 or 100 Mbps management port\n will cause the switch to stop responding until VeriPHY is complete."\n ::= { me1200PortVeriPhyStartEntry 2 }', 'syntax_tree': [['row', 'TruthValue'], None, ['MaxAccessPart', 'read-write'], ['Status', 'current'], ['DESCRIPTION', 'Set to TRUE to start VeriPHy for the interface. When running 10 and 100 Mbps, ports will be linked down while running VeriPHY. Therefore, running VeriPHY on a 10 or 100 Mbps management port will cause the switch to stop responding until VeriPHY is complete.'], None, None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4-q12'} - cisco-products
· Publisher's source file
· Archived source file
· Official repository archive
Source location: ME1200-PORT-MIB::me1200PortVeriPhyStartStart.Source version and references
Published package: Cisco ME1200-MIBS 15.4_3_SN; file: ME1200-MIBS/15.4_3_SN/ME1200-PORT-MIB.mib.
Same file in Cisco ME1200-MIBS 15.6_2_SN.
Same file in Cisco ME1200-MIBS 15.6_1_SN2.
Same file in Cisco ME1200-MIBS 15.6_1_SN1.
Same file in Cisco ME1200-MIBS 15.6_1_SN.
Downloaded: 2026-10-21T03:34:10.793536+00:00. SHA-256:
e1713e9930762d7830a61f364cd948d4268bc4b248bf53727ae5e76f6dee2d91{'kind': 'OBJECT-TYPE', 'details': {'module': 'ME1200-PORT-MIB', 'imports': {'ME1200-TC': ['ME1200InterfaceIndex', 'ME1200DisplayString', 'ME1200Unsigned8'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'CISCOME1200-MIB': ['me1200SwitchMgmt']}, 'document': {'software': 'Cisco ME1200-MIBS', 'original_name': 'ME1200-MIBS/15.4_3_SN/ME1200-PORT-MIB.mib', 'release_sha256': 'fdd5f5f181891a7352b13a73b80cbb24bb2c5ecb0d6d4fd22fc945100c43a009', 'release_version': '15.4_3_SN'}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'me1200PortVeriPhyStartStart OBJECT-TYPE\n SYNTAX TruthValue\n MAX-ACCESS read-write\n STATUS current\n DESCRIPTION \n "Set to TRUE to start VeriPHy for the interface.\n \n When running 10 and 100 Mbps, ports will be linked down while running\n VeriPHY. Therefore, running VeriPHY on a 10 or 100 Mbps management port\n will cause the switch to stop responding until VeriPHY is complete."\n ::= { me1200PortVeriPhyStartEntry 2 }', 'syntax_tree': [['row', 'TruthValue'], None, ['MaxAccessPart', 'read-write'], ['Status', 'current'], ['DESCRIPTION', 'Set to TRUE to start VeriPHy for the interface. When running 10 and 100 Mbps, ports will be linked down while running VeriPHY. Therefore, running VeriPHY on a 10 or 100 Mbps management port will cause the switch to stop responding until VeriPHY is complete.'], None, None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4-q12'} - cisco-products
· Publisher's source file
· Archived source file
· Official repository archive
Source location: ME1200-PORT-MIB::me1200PortVeriPhyStartStart.Source version and references
Published package: Cisco ME1200-MIBS 15.4_3_SN1; file: ME1200-MIBS/15.4_3_SN1/ME1200-PORT-MIB.mib.
Downloaded: 2026-10-21T03:34:10.847535+00:00. SHA-256:
55a12277e9ec4286bf3613522e645df2271d9891f9a7b250f7c9e4ac7c45b82f{'kind': 'OBJECT-TYPE', 'details': {'module': 'ME1200-PORT-MIB', 'imports': {'ME1200-TC': ['ME1200InterfaceIndex', 'ME1200DisplayString', 'ME1200Unsigned8'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'CISCOME1200-MIB': ['me1200SwitchMgmt']}, 'document': {'software': 'Cisco ME1200-MIBS', 'original_name': 'ME1200-MIBS/15.4_3_SN1/ME1200-PORT-MIB.mib', 'release_sha256': 'fdd5f5f181891a7352b13a73b80cbb24bb2c5ecb0d6d4fd22fc945100c43a009', 'release_version': '15.4_3_SN1'}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'me1200PortVeriPhyStartStart OBJECT-TYPE\n SYNTAX TruthValue\n MAX-ACCESS read-write\n STATUS current\n DESCRIPTION \n "Set to TRUE to start VeriPHy for the interface.\n \n When running 10 and 100 Mbps, ports will be linked down while running\n VeriPHY. Therefore, running VeriPHY on a 10 or 100 Mbps management port\n will cause the switch to stop responding until VeriPHY is complete."\n ::= { me1200PortVeriPhyStartEntry 2 }', 'syntax_tree': [['row', 'TruthValue'], None, ['MaxAccessPart', 'read-write'], ['Status', 'current'], ['DESCRIPTION', 'Set to TRUE to start VeriPHy for the interface. When running 10 and 100 Mbps, ports will be linked down while running VeriPHY. Therefore, running VeriPHY on a 10 or 100 Mbps management port will cause the switch to stop responding until VeriPHY is complete.'], None, None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4-q12'} - cisco-products
· Publisher's source file
· Archived source file
· Official repository archive
Source location: ME1200-PORT-MIB::me1200PortVeriPhyStartStart.Source version and references
Published package: Cisco ME1200-MIBS 15.6_4_SN; file: ME1200-MIBS/15.6_4_SN/ME1200-PORT-MIB.mib.
Same file in Cisco ME1200-MIBS 15.6_5_SN.
Downloaded: 2026-10-21T03:34:11.181532+00:00. SHA-256:
9a6d9d55d6a4f1a48662d6067d54007c82684aa68ea32662aa69f786246ec82f{'kind': 'OBJECT-TYPE', 'details': {'module': 'ME1200-PORT-MIB', 'imports': {'ME1200-TC': ['ME1200DisplayString', 'ME1200InterfaceIndex', 'ME1200Unsigned8'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Counter64', 'Integer32', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'CISCOME1200-MIB': ['me1200SwitchMgmt']}, 'document': {'software': 'Cisco ME1200-MIBS', 'original_name': 'ME1200-MIBS/15.6_4_SN/ME1200-PORT-MIB.mib', 'release_sha256': 'fdd5f5f181891a7352b13a73b80cbb24bb2c5ecb0d6d4fd22fc945100c43a009', 'release_version': '15.6_4_SN'}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'me1200PortVeriPhyStartStart OBJECT-TYPE\n SYNTAX TruthValue\n MAX-ACCESS read-write\n STATUS current\n DESCRIPTION \n "Set to TRUE to start VeriPHy for the interface.\n \n When running 10 and 100 Mbps, ports will be linked down while running\n VeriPHY. Therefore, running VeriPHY on a 10 or 100 Mbps management port\n will cause the switch to stop responding until VeriPHY is complete."\n ::= { me1200PortVeriPhyStartEntry 2 }', 'syntax_tree': [['row', 'TruthValue'], None, ['MaxAccessPart', 'read-write'], ['Status', 'current'], ['DESCRIPTION', 'Set to TRUE to start VeriPHy for the interface. When running 10 and 100 Mbps, ports will be linked down while running VeriPHY. Therefore, running VeriPHY on a 10 or 100 Mbps management port will cause the switch to stop responding until VeriPHY is complete.'], None, None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4-q12'}