The inner VLAN ID to be compared. If the InnerVlanIdOp object in the same row is range(2), this object will be the ending VLAN ID of the range. Valid range is 1-4095. This object can only be configured if InnerVlanIdOp is range(2).
Status in source: current.
Names: me1200QosQceTableRowEditorInnerVlanIdRange
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"me1200QosQceTableRowEditorInnerVlanIdRange",
"OBJECT-TYPE",
"SYNTAX",
"ME1200Unsigned16",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The inner VLAN ID to be compared. If the InnerVlanIdOp object in the same row is range(2), this object will be the ending VLAN ID of the range. Valid range is 1-4095. This object can only be configured if InnerVlanIdOp is range(2).\"",
"::=",
"{",
"me1200QosQceTableRowEditor",
"19",
"}"
],
"syntax_tree": [
[
"row",
"ME1200Unsigned16"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The inner VLAN ID to be compared. If the InnerVlanIdOp object in the same row is range(2), this object will be the ending VLAN ID of the range. Valid range is 1-4095. This object can only be configured if InnerVlanIdOp is range(2)."
],
null,
null,
null,
null
]
}- cisco-products
· Publisher's source file
· Archived source file
· Official repository archive
Source location: ME1200-QOS-MIB::me1200QosQceTableRowEditorInnerVlanIdRange.Source version and references
Published package: Cisco ME1200-MIBS 15.4_2_SN1; file: ME1200-MIBS/15.4_2_SN1/ME1200-QOS-MIB.mib.
Downloaded: 2026-10-21T03:34:10.734536+00:00. SHA-256:
469fc86e8ee7da86c9dffe0d1caea86bb1f9839584914d39933a41a98599816c{'kind': 'OBJECT-TYPE', 'details': {'module': 'ME1200-QOS-MIB', 'imports': {'ME1200-TC': ['ME1200Percent', 'ME1200Unsigned8', 'ME1200PortList', 'ME1200Unsigned16', 'ME1200EtherType', 'ME1200RowEditorState', 'ME1200InterfaceIndex'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'MacAddress'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'CISCOME1200-MIB': ['me1200SwitchMgmt'], 'DIFFSERV-DSCP-TC': ['Dscp'], 'INET-ADDRESS-MIB': ['InetAddressIPv6']}, 'document': {'software': 'Cisco ME1200-MIBS', 'original_name': 'ME1200-MIBS/15.4_2_SN1/ME1200-QOS-MIB.mib', 'release_sha256': 'fdd5f5f181891a7352b13a73b80cbb24bb2c5ecb0d6d4fd22fc945100c43a009', 'release_version': '15.4_2_SN1'}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'me1200QosQceTableRowEditorInnerVlanIdRange OBJECT-TYPE\n SYNTAX ME1200Unsigned16\n MAX-ACCESS read-write\n STATUS current\n DESCRIPTION \n "The inner VLAN ID to be compared. If the InnerVlanIdOp object in the\n same row is range(2), this object will be the ending VLAN ID of the\n range. Valid range is 1-4095. This object can only be configured if\n InnerVlanIdOp is range(2)."\n ::= { me1200QosQceTableRowEditor 19 }', 'syntax_tree': [['row', 'ME1200Unsigned16'], None, ['MaxAccessPart', 'read-write'], ['Status', 'current'], ['DESCRIPTION', 'The inner VLAN ID to be compared. If the InnerVlanIdOp object in the same row is range(2), this object will be the ending VLAN ID of the range. Valid range is 1-4095. This object can only be configured if InnerVlanIdOp is range(2).'], None, None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4-q12'} - cisco-products
· Publisher's source file
· Archived source file
· Official repository archive
Source location: ME1200-QOS-MIB::me1200QosQceTableRowEditorInnerVlanIdRange.Source version and references
Published package: Cisco ME1200-MIBS 15.4_3_SN; file: ME1200-MIBS/15.4_3_SN/ME1200-QOS-MIB.mib.
Same file in Cisco ME1200-MIBS 15.6_2_SN.
Same file in Cisco ME1200-MIBS 15.6_1_SN2.
Same file in Cisco ME1200-MIBS 15.6_1_SN1.
Same file in Cisco ME1200-MIBS 15.6_1_SN.
Downloaded: 2026-10-21T03:34:10.799536+00:00. SHA-256:
51da557ffaa05de6e2fa06785397201397ea5ec2ed273744a835e0c4577727da{'kind': 'OBJECT-TYPE', 'details': {'module': 'ME1200-QOS-MIB', 'imports': {'ME1200-TC': ['ME1200Percent', 'ME1200Unsigned8', 'ME1200PortList', 'ME1200Unsigned16', 'ME1200EtherType', 'ME1200RowEditorState', 'ME1200InterfaceIndex'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'MacAddress'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'CISCOME1200-MIB': ['me1200SwitchMgmt'], 'DIFFSERV-DSCP-TC': ['Dscp'], 'INET-ADDRESS-MIB': ['InetAddressIPv6']}, 'document': {'software': 'Cisco ME1200-MIBS', 'original_name': 'ME1200-MIBS/15.4_3_SN/ME1200-QOS-MIB.mib', 'release_sha256': 'fdd5f5f181891a7352b13a73b80cbb24bb2c5ecb0d6d4fd22fc945100c43a009', 'release_version': '15.4_3_SN'}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'me1200QosQceTableRowEditorInnerVlanIdRange OBJECT-TYPE\n SYNTAX ME1200Unsigned16\n MAX-ACCESS read-write\n STATUS current\n DESCRIPTION \n "The inner VLAN ID to be compared. If the InnerVlanIdOp object in the\n same row is range(2), this object will be the ending VLAN ID of the\n range. Valid range is 1-4095. This object can only be configured if\n InnerVlanIdOp is range(2)."\n ::= { me1200QosQceTableRowEditor 19 }', 'syntax_tree': [['row', 'ME1200Unsigned16'], None, ['MaxAccessPart', 'read-write'], ['Status', 'current'], ['DESCRIPTION', 'The inner VLAN ID to be compared. If the InnerVlanIdOp object in the same row is range(2), this object will be the ending VLAN ID of the range. Valid range is 1-4095. This object can only be configured if InnerVlanIdOp is range(2).'], None, None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4-q12'} - cisco-products
· Publisher's source file
· Archived source file
· Official repository archive
Source location: ME1200-QOS-MIB::me1200QosQceTableRowEditorInnerVlanIdRange.Source version and references
Published package: Cisco ME1200-MIBS 15.4_3_SN1; file: ME1200-MIBS/15.4_3_SN1/ME1200-QOS-MIB.mib.
Downloaded: 2026-10-21T03:34:10.848536+00:00. SHA-256:
31f526f5ec4cac284509d894d40871238ff05c217c2a3f733fd3fb1dbb0d2bd3{'kind': 'OBJECT-TYPE', 'details': {'module': 'ME1200-QOS-MIB', 'imports': {'ME1200-TC': ['ME1200Percent', 'ME1200Unsigned8', 'ME1200PortList', 'ME1200Unsigned16', 'ME1200EtherType', 'ME1200RowEditorState', 'ME1200InterfaceIndex'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'MacAddress'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'CISCOME1200-MIB': ['me1200SwitchMgmt'], 'DIFFSERV-DSCP-TC': ['Dscp'], 'INET-ADDRESS-MIB': ['InetAddressIPv6']}, 'document': {'software': 'Cisco ME1200-MIBS', 'original_name': 'ME1200-MIBS/15.4_3_SN1/ME1200-QOS-MIB.mib', 'release_sha256': 'fdd5f5f181891a7352b13a73b80cbb24bb2c5ecb0d6d4fd22fc945100c43a009', 'release_version': '15.4_3_SN1'}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'me1200QosQceTableRowEditorInnerVlanIdRange OBJECT-TYPE\n SYNTAX ME1200Unsigned16\n MAX-ACCESS read-write\n STATUS current\n DESCRIPTION \n "The inner VLAN ID to be compared. If the InnerVlanIdOp object in the\n same row is range(2), this object will be the ending VLAN ID of the\n range. Valid range is 1-4095. This object can only be configured if\n InnerVlanIdOp is range(2)."\n ::= { me1200QosQceTableRowEditor 19 }', 'syntax_tree': [['row', 'ME1200Unsigned16'], None, ['MaxAccessPart', 'read-write'], ['Status', 'current'], ['DESCRIPTION', 'The inner VLAN ID to be compared. If the InnerVlanIdOp object in the same row is range(2), this object will be the ending VLAN ID of the range. Valid range is 1-4095. This object can only be configured if InnerVlanIdOp is range(2).'], None, None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4-q12'} - cisco-products
· Publisher's source file
· Archived source file
· Official repository archive
Source location: ME1200-QOS-MIB::me1200QosQceTableRowEditorInnerVlanIdRange.Source version and references
Published package: Cisco ME1200-MIBS 15.6_4_SN; file: ME1200-MIBS/15.6_4_SN/ME1200-QOS-MIB.mib.
Same file in Cisco ME1200-MIBS 15.6_5_SN.
Downloaded: 2026-10-21T03:34:11.187532+00:00. SHA-256:
f241832a6e41eff65fbd58f3529cbaad377558bbc3c4d838dfc34c6dd4ffa4c1{'kind': 'OBJECT-TYPE', 'details': {'module': 'ME1200-QOS-MIB', 'imports': {'ME1200-TC': ['ME1200EtherType', 'ME1200InterfaceIndex', 'ME1200Percent', 'ME1200PortList', 'ME1200RowEditorState', 'ME1200Unsigned16', 'ME1200Unsigned8'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'MacAddress', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'IpAddress', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'CISCOME1200-MIB': ['me1200SwitchMgmt'], 'DIFFSERV-DSCP-TC': ['Dscp'], 'INET-ADDRESS-MIB': ['InetAddressIPv6']}, 'document': {'software': 'Cisco ME1200-MIBS', 'original_name': 'ME1200-MIBS/15.6_4_SN/ME1200-QOS-MIB.mib', 'release_sha256': 'fdd5f5f181891a7352b13a73b80cbb24bb2c5ecb0d6d4fd22fc945100c43a009', 'release_version': '15.6_4_SN'}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'me1200QosQceTableRowEditorInnerVlanIdRange OBJECT-TYPE\n SYNTAX ME1200Unsigned16\n MAX-ACCESS read-write\n STATUS current\n DESCRIPTION \n "The inner VLAN ID to be compared. If the InnerVlanIdOp object in the\n same row is range(2), this object will be the ending VLAN ID of the\n range. Valid range is 1-4095. This object can only be configured if\n InnerVlanIdOp is range(2)."\n ::= { me1200QosQceTableRowEditor 19 }', 'syntax_tree': [['row', 'ME1200Unsigned16'], None, ['MaxAccessPart', 'read-write'], ['Status', 'current'], ['DESCRIPTION', 'The inner VLAN ID to be compared. If the InnerVlanIdOp object in the same row is range(2), this object will be the ending VLAN ID of the range. Valid range is 1-4095. This object can only be configured if InnerVlanIdOp is range(2).'], None, None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4-q12'}