Type of system LED status clearing.all(0) is used to clear all error status of the system LED and back to normal indication. fatal(1) is used to clear fatal error status of the system LED. software(2) is used to clear generic software error status of the system LED. post(3) is used to clear POST(Power On Self Test) error status of the system LED. ztp(4) is used to clear ZTP(Zero Touch Provisioning) error status of the system LED. stackFwChk(5) is used to clear stack firmware version check error status of the system LED.
Status in source: current.
Names: me1200SysutilControlSystemLedClearStatus
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"me1200SysutilControlSystemLedClearStatus",
"OBJECT-TYPE",
"SYNTAX",
"ME1200SysutilSystemLedClearType",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Type of system LED status clearing.all(0) is used to clear all error status of the system LED and back to normal indication. fatal(1) is used to clear fatal error status of the system LED. software(2) is used to clear generic software error status of the system LED. post(3) is used to clear POST(Power On Self Test) error status of the system LED. ztp(4) is used to clear ZTP(Zero Touch Provisioning) error status of the system LED. stackFwChk(5) is used to clear stack firmware version check error status of the system LED.\"",
"::=",
"{",
"me1200SysutilControlSystemLedEntry",
"2",
"}"
],
"syntax_tree": [
[
"row",
"ME1200SysutilSystemLedClearType"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Type of system LED status clearing.all(0) is used to clear all error status of the system LED and back to normal indication. fatal(1) is used to clear fatal error status of the system LED. software(2) is used to clear generic software error status of the system LED. post(3) is used to clear POST(Power On Self Test) error status of the system LED. ztp(4) is used to clear ZTP(Zero Touch Provisioning) error status of the system LED. stackFwChk(5) is used to clear stack firmware version check error status of the system LED."
],
null,
null,
null,
null
]
}- cisco-products
· Publisher's source file
· Archived source file
· Official repository archive
Source location: ME1200-SYSUTIL-MIB::me1200SysutilControlSystemLedClearStatus.Source version and references
Published package: Cisco ME1200-MIBS 15.6_5_SN; file: ME1200-MIBS/15.6_5_SN/ME1200-SYSUTIL-MIB.mib.
Downloaded: 2026-10-21T03:34:11.246532+00:00. SHA-256:
a7d49adbe763c48e5fa90450c8924b4dbdcf95e7d57a51b82fc8b4127a39d292{'kind': 'OBJECT-TYPE', 'details': {'module': 'ME1200-SYSUTIL-MIB', 'imports': {'ME1200-TC': ['ME1200DisplayString', 'ME1200Unsigned8'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'CISCOME1200-MIB': ['me1200SwitchMgmt']}, 'document': {'software': 'Cisco ME1200-MIBS', 'original_name': 'ME1200-MIBS/15.6_5_SN/ME1200-SYSUTIL-MIB.mib', 'release_sha256': 'fdd5f5f181891a7352b13a73b80cbb24bb2c5ecb0d6d4fd22fc945100c43a009', 'release_version': '15.6_5_SN'}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'me1200SysutilControlSystemLedClearStatus OBJECT-TYPE\n SYNTAX ME1200SysutilSystemLedClearType\n MAX-ACCESS read-write\n STATUS current\n DESCRIPTION \n "Type of system LED status clearing.all(0) is used to clear all error\n status of the system LED and back to normal indication. fatal(1) is\n used to clear fatal error status of the system LED. software(2) is used\n to clear generic software error status of the system LED. post(3) is\n used to clear POST(Power On Self Test) error status of the system LED.\n ztp(4) is used to clear ZTP(Zero Touch Provisioning) error status of\n the system LED. stackFwChk(5) is used to clear stack firmware version\n check error status of the system LED."\n ::= { me1200SysutilControlSystemLedEntry 2 }', 'syntax_tree': [['row', 'ME1200SysutilSystemLedClearType'], None, ['MaxAccessPart', 'read-write'], ['Status', 'current'], ['DESCRIPTION', 'Type of system LED status clearing.all(0) is used to clear all error status of the system LED and back to normal indication. fatal(1) is used to clear fatal error status of the system LED. software(2) is used to clear generic software error status of the system LED. post(3) is used to clear POST(Power On Self Test) error status of the system LED. ztp(4) is used to clear ZTP(Zero Touch Provisioning) error status of the system LED. stackFwChk(5) is used to clear stack firmware version check error status of the system LED.'], None, None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4-q12'}