Set to TRUE to start VeriPHy for the interface. When running 10 and 100 Mbps, ports will be linked down while running VeriPHY. Therefore, running VeriPHY on a 10 or 100 Mbps management port will cause the switch to stop responding until VeriPHY is complete.
Status in source: current.
Names: cie1000PortControlVeriPhyStartStart
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cie1000PortControlVeriPhyStartStart",
"OBJECT-TYPE",
"SYNTAX",
"TruthValue",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Set to TRUE to start VeriPHy for the interface. When running 10 and 100 Mbps, ports will be linked down while running VeriPHY. Therefore, running VeriPHY on a 10 or 100 Mbps management port will cause the switch to stop responding until VeriPHY is complete.\"",
"::=",
"{",
"cie1000PortControlVeriPhyStartEntry",
"2",
"}"
],
"syntax_tree": [
[
"row",
"TruthValue"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Set to TRUE to start VeriPHy for the interface. When running 10 and 100 Mbps, ports will be linked down while running VeriPHY. Therefore, running VeriPHY on a 10 or 100 Mbps management port will cause the switch to stop responding until VeriPHY is complete."
],
null,
null,
null,
null
]
}- cisco-products
· Publisher's source file
· Archived source file
· Official repository archive
· Original product package
· Original product package
Source location: CIE1000-PORT-MIB::cie1000PortControlVeriPhyStartStart.Source version and references
Published package: Cisco IE1000-MIBS IE1000_MIBs; file: IE1000-MIBS/IE1000_MIBs.7z/CIE1000-PORT-MIB.mib.
Same file in Cisco STRATIX2500-MIBS Stratix2500_MIBs.
Downloaded: 2026-10-21T03:34:10.618537+00:00. SHA-256:
51828a5c86f47a548b496f6d12fb2beb0cf9aebf707cdb148cb394634752928b{'kind': 'OBJECT-TYPE', 'details': {'module': 'CIE1000-PORT-MIB', 'imports': {'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue'], 'CIE1000-TC': ['CIE1000DisplayString', 'CIE1000InterfaceIndex', 'CIE1000PortStatusSpeed', 'CIE1000SfpTransceiver', 'CIE1000Unsigned8'], 'SNMPv2-SMI': ['NOTIFICATION-TYPE', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'Counter64', 'Integer32', 'Unsigned32'], 'SNMPv2-CONF': ['NOTIFICATION-GROUP', 'MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'CISCO-IE1000-MIB': ['cie1000SwitchMgmt']}, 'document': {'software': 'Cisco IE1000-MIBS', 'original_name': 'IE1000-MIBS/IE1000_MIBs.7z/CIE1000-PORT-MIB.mib', 'release_sha256': 'fdd5f5f181891a7352b13a73b80cbb24bb2c5ecb0d6d4fd22fc945100c43a009', 'release_version': 'IE1000_MIBs'}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'cie1000PortControlVeriPhyStartStart OBJECT-TYPE\n SYNTAX TruthValue\n MAX-ACCESS read-write\n STATUS current\n DESCRIPTION\n "Set to TRUE to start VeriPHy for the interface.\n \n When running 10 and 100 Mbps, ports will be linked down while running\n VeriPHY. Therefore, running VeriPHY on a 10 or 100 Mbps management port\n will cause the switch to stop responding until VeriPHY is complete."\n ::= { cie1000PortControlVeriPhyStartEntry 2 }', 'syntax_tree': [['row', 'TruthValue'], None, ['MaxAccessPart', 'read-write'], ['Status', 'current'], ['DESCRIPTION', 'Set to TRUE to start VeriPHy for the interface. When running 10 and 100 Mbps, ports will be linked down while running VeriPHY. Therefore, running VeriPHY on a 10 or 100 Mbps management port will cause the switch to stop responding until VeriPHY is complete.'], None, None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4-q12'}