Indicates what level of message will send to syslog server. For example, the error level will send the specific messages which severity code is less or equal than error(3), the warning level will send the specific messages which severity code is less or equal than warning(4), the notice level will send the specific messages which severity code is less or equal than notice(5), the informational level will send the specific messages which severity code is less or equal than informational(6) and the enumeration option of all(8) isn't used in this case.
Status in source: current.
Names: cie1000SyslogConfigServerLevel
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cie1000SyslogConfigServerLevel",
"OBJECT-TYPE",
"SYNTAX",
"CIE1000SyslogLevelType",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Indicates what level of message will send to syslog server. For example, the error level will send the specific messages which severity code is less or equal than error(3), the warning level will send the specific messages which severity code is less or equal than warning(4), the notice level will send the specific messages which severity code is less or equal than notice(5), the informational level will send the specific messages which severity code is less or equal than informational(6) and the enumeration option of all(8) isn't used in this case.\"",
"::=",
"{",
"cie1000SyslogConfigServer",
"3",
"}"
],
"syntax_tree": [
[
"row",
"CIE1000SyslogLevelType"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Indicates what level of message will send to syslog server. For example, the error level will send the specific messages which severity code is less or equal than error(3), the warning level will send the specific messages which severity code is less or equal than warning(4), the notice level will send the specific messages which severity code is less or equal than notice(5), the informational level will send the specific messages which severity code is less or equal than informational(6) and the enumeration option of all(8) isn't used in this case."
],
null,
null,
null,
null
]
}- cisco-products
· Publisher's source file
· Archived source file
· Official repository archive
· Original product package
· Original product package
Source location: CIE1000-SYSLOG-MIB::cie1000SyslogConfigServerLevel.Source version and references
Published package: Cisco IE1000-MIBS IE1000_MIBs; file: IE1000-MIBS/IE1000_MIBs.7z/CIE1000-SYSLOG-MIB.mib.
Same file in Cisco STRATIX2500-MIBS Stratix2500_MIBs.
Downloaded: 2026-10-21T03:34:10.664537+00:00. SHA-256:
7b89cd17127a451057fe2aad8713239b3aed79955026232a6779c1c8829d2b1f{'kind': 'OBJECT-TYPE', 'details': {'module': 'CIE1000-SYSLOG-MIB', 'imports': {'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DateAndTime', 'TruthValue'], 'CIE1000-TC': ['CIE1000DisplayString', 'CIE1000InetAddress'], 'SNMPv2-SMI': ['NOTIFICATION-TYPE', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32'], 'SNMPv2-CONF': ['NOTIFICATION-GROUP', 'MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'CISCO-IE1000-MIB': ['cie1000SwitchMgmt']}, 'document': {'software': 'Cisco IE1000-MIBS', 'original_name': 'IE1000-MIBS/IE1000_MIBs.7z/CIE1000-SYSLOG-MIB.mib', 'release_sha256': 'fdd5f5f181891a7352b13a73b80cbb24bb2c5ecb0d6d4fd22fc945100c43a009', 'release_version': 'IE1000_MIBs'}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'cie1000SyslogConfigServerLevel OBJECT-TYPE\n SYNTAX CIE1000SyslogLevelType\n MAX-ACCESS read-write\n STATUS current\n DESCRIPTION\n "Indicates what level of message will send to syslog server. For\n example, the error level will send the specific messages which severity\n code is less or equal than error(3), the warning level will send the\n specific messages which severity code is less or equal than warning(4),\n the notice level will send the specific messages which severity code is\n less or equal than notice(5), the informational level will send the\n specific messages which severity code is less or equal than\n informational(6) and the enumeration option of all(8) isn\'t used in\n this case."\n ::= { cie1000SyslogConfigServer 3 }', 'syntax_tree': [['row', 'CIE1000SyslogLevelType'], None, ['MaxAccessPart', 'read-write'], ['Status', 'current'], ['DESCRIPTION', "Indicates what level of message will send to syslog server. For example, the error level will send the specific messages which severity code is less or equal than error(3), the warning level will send the specific messages which severity code is less or equal than warning(4), the notice level will send the specific messages which severity code is less or equal than notice(5), the informational level will send the specific messages which severity code is less or equal than informational(6) and the enumeration option of all(8) isn't used in this case."], None, None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4-q12'}