This notification is generated when the value of cooOtsControllerStatus changes. The varbind for this notification indicates the ifIndex, ifname of the OTS interface as well as controller port type and status.
Status in source: current.
Names: cooOtsStatusChange
Technical details
{
"smi_kind": "NOTIFICATION-TYPE",
"definition": [
"cooOtsStatusChange",
"NOTIFICATION-TYPE",
"OBJECTS",
"{",
"ifIndex",
",",
"ifName",
",",
"cooOtsControllerPortType",
",",
"cooOtsControllerAlarmState",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"This notification is generated when the value of cooOtsControllerStatus changes. The varbind for this notification indicates the ifIndex, ifname of the OTS interface as well as controller port type and status.\"",
"::=",
"{",
"ciscoOpticalOtsMIBNotifs",
"1",
"}"
],
"syntax_tree": [
[
"Objects",
[
"ifIndex",
"ifName",
"cooOtsControllerPortType",
"cooOtsControllerAlarmState"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This notification is generated when the value of cooOtsControllerStatus changes. The varbind for this notification indicates the ifIndex, ifname of the OTS interface as well as controller port type and status."
],
null
]
}- Cisco
· Publisher's source file
· Archived source file
Source location: CISCO-OPTICAL-OTS-MIB::cooOtsStatusChange.Source version and references
Downloaded: 2026-10-19T00:18:11.826519+00:00. SHA-256:
6a529a58138f5380fe48347ead131db7810f78bcff8cf6519c9c79cea93b2098{'kind': 'NOTIFICATION-TYPE', 'details': {'module': 'CISCO-OPTICAL-OTS-MIB', 'imports': {'IF-MIB': ['ifIndex', 'ifName'], 'CISCO-SMI': ['ciscoMgmt'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'TimeStamp', 'DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'CISCO-OPTICAL-MIB': ['CoiOpticalPower', 'CoiOpticalWavelength', 'CoiIntervalType', 'CoiOptAlarmType', 'CoiOptAlarmSeverity', 'CoiOptAlarmStatus', 'CoiOptAlarmServiceAffecting'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}, 'smi_kind': 'NOTIFICATION-TYPE', 'definition': 'cooOtsStatusChange NOTIFICATION-TYPE\n OBJECTS {\n ifIndex,\n ifName,\n cooOtsControllerPortType,\n cooOtsControllerAlarmState\n }\n STATUS current\n DESCRIPTION\n "This notification is generated when the value of\n cooOtsControllerStatus changes.\n The varbind for this notification indicates the ifIndex,\n ifname of the OTS interface as well as controller port type and status."\n ::= { ciscoOpticalOtsMIBNotifs 1 }', 'syntax_tree': [['Objects', ['ifIndex', 'ifName', 'cooOtsControllerPortType', 'cooOtsControllerAlarmState']], ['Status', 'current'], ['DESCRIPTION', 'This notification is generated when the value of cooOtsControllerStatus changes. The varbind for this notification indicates the ifIndex, ifname of the OTS interface as well as controller port type and status.'], None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}