This object indicates the result of the latest write operation to ciscoCableLicenseEnforcementEnabled or ciscoCableLicenseCapLimit 'noError' : The operation was successful. 'configLocked' : write failed because the CMTS is in config locked state. 'cappedEnabledAlready': write failed because the capped enforcement has already been enabled for this feature. 'cappedLessThanUsed': write failed because the capped count to be set is less than what was being used. 'cappedCountSaveFail': This is due to writing into database failed. 'cmtsNotReady': This may happend when try to send write request during cmts is booting up. 'wrongValue': This indicates the value of user input is an invalid value
Status in source: current.
Names: ciscoCableLicenseLastActionFailCause
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ciscoCableLicenseLastActionFailCause",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"noError",
"(",
"1",
")",
",",
"configLocked",
"(",
"2",
")",
",",
"cappedEnabledAlready",
"(",
"3",
")",
",",
"cappedLessThanUsed",
"(",
"4",
")",
",",
"cappedCountSaveFail",
"(",
"5",
")",
",",
"cmtsNotReady",
"(",
"6",
")",
",",
"wrongValue",
"(",
"7",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"This object indicates the result of the latest write operation to ciscoCableLicenseEnforcementEnabled or ciscoCableLicenseCapLimit 'noError' : The operation was successful. 'configLocked' : write failed because the CMTS is in config locked state. 'cappedEnabledAlready': write failed because the capped enforcement has already been enabled for this feature. 'cappedLessThanUsed': write failed because the capped count to be set is less than what was being used. 'cappedCountSaveFail': This is due to writing into database failed. 'cmtsNotReady': This may happend when try to send write request during cmts is booting up. 'wrongValue': This indicates the value of user input is an invalid value\"",
"::=",
"{",
"ciscoCableLicenseInfoEntry",
"7",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"noError",
1
],
[
"configLocked",
2
],
[
"cappedEnabledAlready",
3
],
[
"cappedLessThanUsed",
4
],
[
"cappedCountSaveFail",
5
],
[
"cmtsNotReady",
6
],
[
"wrongValue",
7
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object indicates the result of the latest write operation to ciscoCableLicenseEnforcementEnabled or ciscoCableLicenseCapLimit 'noError' : The operation was successful. 'configLocked' : write failed because the CMTS is in config locked state. 'cappedEnabledAlready': write failed because the capped enforcement has already been enabled for this feature. 'cappedLessThanUsed': write failed because the capped count to be set is less than what was being used. 'cappedCountSaveFail': This is due to writing into database failed. 'cmtsNotReady': This may happend when try to send write request during cmts is booting up. 'wrongValue': This indicates the value of user input is an invalid value"
],
null,
null,
null,
null
]
}- Cisco
· Publisher's source file
· Archived source file
Source location: CISCO-CABLE-LICENSE-MIB::ciscoCableLicenseLastActionFailCause.Source version and references
Downloaded: 2026-10-19T00:18:11.067037+00:00. SHA-256:
4fe4e65feb838d4f82ccd6b3d017c43323ba83484019522fc6a11f585a9d81e8{'kind': 'OBJECT-TYPE', 'details': {'module': 'CISCO-CABLE-LICENSE-MIB', 'imports': {'CISCO-SMI': ['ciscoMgmt'], 'SNMPv2-TC': ['TimeStamp'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'Unsigned32', 'Integer32'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ciscoCableLicenseLastActionFailCause OBJECT-TYPE\n SYNTAX INTEGER {\n noError(1),\n configLocked(2),\n cappedEnabledAlready(3),\n cappedLessThanUsed(4),\n cappedCountSaveFail(5),\n cmtsNotReady(6),\n wrongValue(7)\n }\n MAX-ACCESS read-only\n STATUS current\n DESCRIPTION\n "This object indicates the result of the latest write operation to\n ciscoCableLicenseEnforcementEnabled or\n ciscoCableLicenseCapLimit\n\n \'noError\' : The operation was successful.\n \'configLocked\' : write failed because the CMTS is in config locked\n state.\n \'cappedEnabledAlready\': write failed because the capped enforcement has\n already been enabled for this feature.\n \'cappedLessThanUsed\': write failed because the capped count to be set\n is less than what was being used.\n \'cappedCountSaveFail\': This is due to writing into database failed.\n \'cmtsNotReady\': This may happend when try to send write request during cmts is booting up.\n \'wrongValue\': This indicates the value of user input is an invalid \n value"\n\n ::= { ciscoCableLicenseInfoEntry 7 }', 'syntax_tree': [['SimpleSyntax', 'INTEGER', ['enumSpec', [['noError', 1], ['configLocked', 2], ['cappedEnabledAlready', 3], ['cappedLessThanUsed', 4], ['cappedCountSaveFail', 5], ['cmtsNotReady', 6], ['wrongValue', 7]]]], None, ['MaxAccessPart', 'read-only'], ['Status', 'current'], ['DESCRIPTION', "This object indicates the result of the latest write operation to ciscoCableLicenseEnforcementEnabled or ciscoCableLicenseCapLimit 'noError' : The operation was successful. 'configLocked' : write failed because the CMTS is in config locked state. 'cappedEnabledAlready': write failed because the capped enforcement has already been enabled for this feature. 'cappedLessThanUsed': write failed because the capped count to be set is less than what was being used. 'cappedCountSaveFail': This is due to writing into database failed. 'cmtsNotReady': This may happend when try to send write request during cmts is booting up. 'wrongValue': This indicates the value of user input is an invalid value"], None, None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}