upsOverLoad

1.3.6.1.4.1.935.0.2

Description

SEVERE: The UPS has sensed a load greater than 100 percent of its rated capacity.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.935.0 (0)
Node code
2
Node name
upsOverLoad
Category
SNMP notification
Numeric OID
1.3.6.1.4.1.935.0.2
URN notation
urn:oid:1.3.6.1.4.1.935.0.2
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 935 0 2}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ppc(935) 0 upsOverLoad(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ppc(935) 0 upsOverLoad(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppc(935) 0 upsOverLoad(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ppc(935) 0 upsOverLoad(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ppc(935) 0 upsOverLoad(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ppc(935) 0 upsOverLoad(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppc(935) 0 upsOverLoad(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) ppc(935) 0 upsOverLoad(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ppc(935) 0 upsOverLoad(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ppc(935) 0 upsOverLoad(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppc(935) 0 upsOverLoad(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ppc(935) 0 upsOverLoad(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) ppc(935) 0 upsOverLoad(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) ppc(935) 0 upsOverLoad(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppc(935) 0 upsOverLoad(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ppc(935) 0 upsOverLoad(2)}
OID-IRI notation
  • /1/3/6/1/4/1/935/0/2
  • /ISO/Identified-Organization/6/1/4/1/935/0/2
  • /ISO/3/6/1/4/1/935/0/2
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/935/0/upsOverLoad
  • /iso/identified-organization/dod/internet/private/enterprise/ppc/0/upsOverLoad
  • /iso/identified-organization/dod/internet/private/enterprises/935/0/upsOverLoad
  • /iso/identified-organization/dod/internet/private/enterprises/ppc/0/upsOverLoad
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/935/0/upsOverLoad
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/ppc/0/upsOverLoad
  • /iso/identified-organization/dod/internet/private/vendor-objects/935/0/upsOverLoad
  • /iso/identified-organization/dod/internet/private/vendor-objects/ppc/0/upsOverLoad
  • /iso/org/dod/internet/private/enterprise/935/0/upsOverLoad
  • /iso/org/dod/internet/private/enterprise/ppc/0/upsOverLoad
  • /iso/org/dod/internet/private/enterprises/935/0/upsOverLoad
  • /iso/org/dod/internet/private/enterprises/ppc/0/upsOverLoad
  • /iso/org/dod/internet/private/ldap-enterprise/935/0/upsOverLoad
  • /iso/org/dod/internet/private/ldap-enterprise/ppc/0/upsOverLoad
  • /iso/org/dod/internet/private/vendor-objects/935/0/upsOverLoad
  • /iso/org/dod/internet/private/vendor-objects/ppc/0/upsOverLoad
  • Additional combinations skipped.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

upsOverLoad · unspecified

upsOverLoad TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "SEVERE: The UPS has sensed a load greater than 100 percent
                of its rated capacity."
        --#TYPE "PPC UPS: UPS overload"
        --#SUMMARY "The UPS has sensed a load greater than 100 percent of its rated capacity."
        --#ARGUMENTS { }
        --#SEVERITY CRITICAL
        --#TIMEINDEX 1
        --#HELP ""
        --#HELPTAG 0
        --#STATE DEGRADED
 ::= 2

upsOverLoad · unspecified

upsOverLoad TRAP-TYPE
	ENTERPRISE ppc
	DESCRIPTION
		"SEVERE: The UPS has sensed a load greater than 100 percent
		 of its rated capacity."
   --#TYPE "PPC UPS: UPS overload"
   --#SUMMARY "The UPS has sensed a load greater than 100 percent of its rated capacity."
   --#ARGUMENTS { }
   --#SEVERITY CRITICAL
   --#TIMEINDEX 1
   --#STATE DEGRADED
	::= 2

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

SEVERE: The UPS has sensed a load greater than 100 percent of its rated capacity.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Reviewed vendor MIB copies in Fujitsu ServerViewCommon and standard MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Reviewed vendor MIB copies in Fujitsu ServerView, and others1 record · 5 sources

Description 1

upsOverLoad · unspecifiedMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Reviewed vendor MIB copies in Fujitsu ServerView, and others5 sources

Status in source: unspecified.

Names: upsOverLoad

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "upsOverLoad",
    "TRAP-TYPE",
    "ENTERPRISE",
    "ppc",
    "DESCRIPTION",
    "\"SEVERE: The UPS has sensed a load greater than 100 percent of its rated capacity.\"",
    "::=",
    "2"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "ppc"
      ]
    ],
    [],
    [
      "DESCRIPTION",
      "SEVERE: The UPS has sensed a load greater than 100 percent of its rated capacity."
    ],
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.935)

An-Hsiang Tu

Siblings (58)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.935.0.1 communicationLost00
1.3.6.1.4.1.935.0.3 upsDiagnosticsFailed00
1.3.6.1.4.1.935.0.4 upsDischarged00
1.3.6.1.4.1.935.0.5 upsOnBattery00
1.3.6.1.4.1.935.0.6 boostOn00
1.3.6.1.4.1.935.0.7 lowBattery00
1.3.6.1.4.1.935.0.8 communicationEstablished00
1.3.6.1.4.1.935.0.9 powerRestored00
1.3.6.1.4.1.935.0.10 upsDiagnosticsPassed00
1.3.6.1.4.1.935.0.11 returnFromLowBattery00
1.3.6.1.4.1.935.0.12 upsTurnedOff00
1.3.6.1.4.1.935.0.13 upsSleeping00
1.3.6.1.4.1.935.0.14 upsWokeUp00
1.3.6.1.4.1.935.0.15 upsRebootStarted00
1.3.6.1.4.1.935.0.16 envOverTemperature00
1.3.6.1.4.1.935.0.17 envTemperatureNormal00
1.3.6.1.4.1.935.0.18 envOverHumidity00
1.3.6.1.4.1.935.0.19 envHumidityNormal00
1.3.6.1.4.1.935.0.20 envSmokeAbnormal00
1.3.6.1.4.1.935.0.21 envWaterAbnormal00
1.3.6.1.4.1.935.0.22 envSecurityAbnormal00
1.3.6.1.4.1.935.0.24 envWaterNormal00
1.3.6.1.4.1.935.0.26 envGasAbnormal00
1.3.6.1.4.1.935.0.27 upsTemp00
1.3.6.1.4.1.935.0.28 upsLoadNormal00
1.3.6.1.4.1.935.0.29 upsTempNormal00
1.3.6.1.4.1.935.0.30 envUnderTemperature00
1.3.6.1.4.1.935.0.31 envUnderHumidity00
1.3.6.1.4.1.935.0.32 upsBypass00
1.3.6.1.4.1.935.0.33 envSecurity100
1.3.6.1.4.1.935.0.34 envSecurity200
1.3.6.1.4.1.935.0.35 envSecurity300
1.3.6.1.4.1.935.0.36 envSecurity400
1.3.6.1.4.1.935.0.37 envSecurity500
1.3.6.1.4.1.935.0.38 envSecurity600
1.3.6.1.4.1.935.0.39 envSecurity700
1.3.6.1.4.1.935.0.47 upsRecroterror00
1.3.6.1.4.1.935.0.48 upsBypassFreFail00
1.3.6.1.4.1.935.0.49 upsBypassacnormal00
1.3.6.1.4.1.935.0.50 upsBypassacabnormal00
1.3.6.1.4.1.935.0.51 upsTest00
1.3.6.1.4.1.935.0.52 upsScheduleShutdown00
1.3.6.1.4.1.935.0.53 upsBypassReturn00
1.3.6.1.4.1.935.0.54 upsShortCircuitShutdown00
1.3.6.1.4.1.935.0.55 upsInverterOutputFailShutdown00
1.3.6.1.4.1.935.0.56 upsBypassBreadkerOnShutdown00
1.3.6.1.4.1.935.0.57 upsHighDCShutdown00
1.3.6.1.4.1.935.0.58 upsEmergencyStop00
1.3.6.1.4.1.935.0.59 upsInverterMode00
1.3.6.1.4.1.935.0.60 upsBypassMode00