upsSmartInputLineFailCause

1.3.6.1.4.1.935.1.1.1.3.2.5

Description

The reason for the occurrence of the last transfer to UPS battery power. The variable is set to noTransfer(1) if there is no transfer yet. The variable is set to highLineVoltage(2) if the transfer to battery is caused by an over voltage greater than the high transfer voltage. The variable is set to brownout(3) if the …

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.935.1.1.1.3.2 (upsSmartInput)
Node code
5
Node name
upsSmartInputLineFailCause
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.935.1.1.1.3.2.5
URN notation
urn:oid:1.3.6.1.4.1.935.1.1.1.3.2.5
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 935 1 1 1 3 2 5}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsInputp(3) upsSmartInput(2) upsSmartInputLineFailCause(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsInput(3) upsSmartInput(2) upsSmartInputLineFailCause(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ppc(935) products(1) hardware(1) ups(1) upsInputp(3) upsSmartInput(2) upsSmartInputLineFailCause(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ppc(935) products(1) hardware(1) ups(1) upsInput(3) upsSmartInput(2) upsSmartInputLineFailCause(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsInputp(3) upsSmartInput(2) upsSmartInputLineFailCause(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsInput(3) upsSmartInput(2) upsSmartInputLineFailCause(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ppc(935) products(1) hardware(1) ups(1) upsInputp(3) upsSmartInput(2) upsSmartInputLineFailCause(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ppc(935) products(1) hardware(1) ups(1) upsInput(3) upsSmartInput(2) upsSmartInputLineFailCause(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsInputp(3) upsSmartInput(2) upsSmartInputLineFailCause(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsInput(3) upsSmartInput(2) upsSmartInputLineFailCause(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ppc(935) products(1) hardware(1) ups(1) upsInputp(3) upsSmartInput(2) upsSmartInputLineFailCause(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ppc(935) products(1) hardware(1) ups(1) upsInput(3) upsSmartInput(2) upsSmartInputLineFailCause(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsInputp(3) upsSmartInput(2) upsSmartInputLineFailCause(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsInput(3) upsSmartInput(2) upsSmartInputLineFailCause(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) ppc(935) products(1) hardware(1) ups(1) upsInputp(3) upsSmartInput(2) upsSmartInputLineFailCause(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) ppc(935) products(1) hardware(1) ups(1) upsInput(3) upsSmartInput(2) upsSmartInputLineFailCause(5)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/935/1/1/1/3/2/5
  • /ISO/Identified-Organization/6/1/4/1/935/1/1/1/3/2/5
  • /ISO/3/6/1/4/1/935/1/1/1/3/2/5
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/935/1/hardware/ups/upsInputp/upsSmartInput/upsSmartInputLineFailCause
  • /iso/identified-organization/dod/internet/private/enterprise/935/1/hardware/ups/upsInput/upsSmartInput/upsSmartInputLineFailCause
  • /iso/identified-organization/dod/internet/private/enterprise/935/products/hardware/ups/upsInputp/upsSmartInput/upsSmartInputLineFailCause
  • /iso/identified-organization/dod/internet/private/enterprise/935/products/hardware/ups/upsInput/upsSmartInput/upsSmartInputLineFailCause
  • /iso/identified-organization/dod/internet/private/enterprise/ppc/1/hardware/ups/upsInputp/upsSmartInput/upsSmartInputLineFailCause
  • /iso/identified-organization/dod/internet/private/enterprise/ppc/1/hardware/ups/upsInput/upsSmartInput/upsSmartInputLineFailCause
  • /iso/identified-organization/dod/internet/private/enterprise/ppc/products/hardware/ups/upsInputp/upsSmartInput/upsSmartInputLineFailCause
  • /iso/identified-organization/dod/internet/private/enterprise/ppc/products/hardware/ups/upsInput/upsSmartInput/upsSmartInputLineFailCause
  • /iso/identified-organization/dod/internet/private/enterprises/935/1/hardware/ups/upsInputp/upsSmartInput/upsSmartInputLineFailCause
  • /iso/identified-organization/dod/internet/private/enterprises/935/1/hardware/ups/upsInput/upsSmartInput/upsSmartInputLineFailCause
  • /iso/identified-organization/dod/internet/private/enterprises/935/products/hardware/ups/upsInputp/upsSmartInput/upsSmartInputLineFailCause
  • /iso/identified-organization/dod/internet/private/enterprises/935/products/hardware/ups/upsInput/upsSmartInput/upsSmartInputLineFailCause
  • /iso/identified-organization/dod/internet/private/enterprises/ppc/1/hardware/ups/upsInputp/upsSmartInput/upsSmartInputLineFailCause
  • /iso/identified-organization/dod/internet/private/enterprises/ppc/1/hardware/ups/upsInput/upsSmartInput/upsSmartInputLineFailCause
  • /iso/identified-organization/dod/internet/private/enterprises/ppc/products/hardware/ups/upsInputp/upsSmartInput/upsSmartInputLineFailCause
  • /iso/identified-organization/dod/internet/private/enterprises/ppc/products/hardware/ups/upsInput/upsSmartInput/upsSmartInputLineFailCause
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
mandatory

Enumerated values

ValueName
1noTransfer
2highLineVoltage
3brownout
4blackout
5smallMomentarySag
6deepMomentarySag
7smallMomentarySpike
8largeMomentarySpike

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.935.1.1.1.3.2.5.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

upsSmartInputLineFailCause · mandatory

upsSmartInputLineFailCause OBJECT-TYPE
        SYNTAX INTEGER {
                        noTransfer(1),
                        highLineVoltage(2),
                        brownout(3),
                        blackout(4),
                        smallMomentarySag(5),
                        deepMomentarySag(6),
                        smallMomentarySpike(7),
                        largeMomentarySpike(8) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The reason for the occurrence of the last transfer
                to UPS battery power.  The variable is set to
                noTransfer(1) if there is no transfer yet.   The variable
                is set to highLineVoltage(2) if the transfer to battery is
                caused by an over voltage greater than the high transfer
                voltage. The variable is set to brownout(3) if the duration
                of the outage is greater than five seconds and the line
                voltage is between 40 percent of the rated output voltage and
                the low transfer voltage. The variable is set to blackout(4)
                if the duration of the outage is greater than five seconds and
                the line voltage is between 40 percent of the rated output voltage
                and ground.  The variable is set to smallMomentarySag(5)
                if the duration of the outage is less than five seconds and
                the line voltage is between 40 percent of the rated output voltage
                and the low transfer voltage.  The variable is set to
                deepMomentarySag(6) if the duration of the outage is less
                than five seconds and the line voltage is between 40 percent of the
                rated output voltage and ground."
   ::= { upsSmartInput 5 }

upsSmartInputLineFailCause · mandatory

upsSmartInputLineFailCause OBJECT-TYPE
	SYNTAX INTEGER  {
		noTransfer(1),
		highLineVoltage(2),
		brownout(3),
		blackout(4),
		smallMomentarySag(5),
		deepMomentarySag(6),
		smallMomentarySpike(7),
		largeMomentarySpike(8)
	}
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"The reason for the occurrence of the last transfer
		 to UPS battery power.  The variable is set to
		 noTransfer(1) if there is no transfer yet.   The variable
		 is set to highLineVoltage(2) if the transfer to battery is
		 caused by an over voltage greater than the high transfer
		 voltage. The variable is set to brownout(3) if the duration
		 of the outage is greater than five seconds and the line
		 voltage is between 40% of the rated output voltage and
		 the low transfer voltage. The variable is set to blackout(4)
		 if the duration of the outage is greater than five seconds and
		 the line voltage is between 40% of the rated output voltage
		 and ground.  The variable is set to smallMomentarySag(5)
		 if the duration of the outage is less than five seconds and
		 the line voltage is between 40% of the rated output voltage
		 and the low transfer voltage.  The variable is set to
		 deepMomentarySag(6) if the duration of the outage is less
		 than five seconds and the line voltage is between 40% of the
		 rated output voltage and ground."
	::= { upsSmartInput 5 }

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

The reason for the occurrence of the last transfer to UPS battery power. The variable is set to noTransfer(1) if there is no transfer yet. The variable is set to highLineVoltage(2) if the transfer to battery is caused by an over voltage greater than the high transfer voltage. The variable is set to brownout(3) if the duration of the outage is greater than five seconds and the line voltage is between 40 percent of the rated output voltage and the low transfer voltage. The variable is set to blackout(4) if the duration of the outage is greater than five seconds and the line voltage is between 40 percent of the rated output voltage and ground. The variable is set to smallMomentarySag(5) if the duration of the outage is less than five seconds and the line voltage is between 40 percent of the rated output voltage and the low transfer voltage. The variable is set to deepMomentarySag(6) if the duration of the outage is less than five seconds and the line voltage is between 40 percent of the rated output voltage and ground.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Common and standard MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies

See 1 matching source record

Description 2

The reason for the occurrence of the last transfer to UPS battery power. The variable is set to noTransfer(1) if there is no transfer yet. The variable is set to highLineVoltage(2) if the transfer to battery is caused by an over voltage greater than the high transfer voltage. The variable is set to brownout(3) if the duration of the outage is greater than five seconds and the line voltage is between 40% of the rated output voltage and the low transfer voltage. The variable is set to blackout(4) if the duration of the outage is greater than five seconds and the line voltage is between 40% of the rated output voltage and ground. The variable is set to smallMomentarySag(5) if the duration of the outage is less than five seconds and the line voltage is between 40% of the rated output voltage and the low transfer voltage. The variable is set to deepMomentarySag(6) if the duration of the outage is less than five seconds and the line voltage is between 40% of the rated output voltage and ground.

Sources for this description

Reviewed vendor MIB copies in Fujitsu ServerView

See 1 matching source record

Evidence

Source records

2 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Common and standard MIB copies (LibreNMS/Observium Community), and others1 record · 4 sources

Description 1

upsSmartInputLineFailCause · mandatoryMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Common and standard MIB copies (LibreNMS/Observium Community), and others4 sources

Status in source: mandatory.

Names: upsSmartInputLineFailCause

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "upsSmartInputLineFailCause",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "noTransfer",
    "(",
    "1",
    ")",
    ",",
    "highLineVoltage",
    "(",
    "2",
    ")",
    ",",
    "brownout",
    "(",
    "3",
    ")",
    ",",
    "blackout",
    "(",
    "4",
    ")",
    ",",
    "smallMomentarySag",
    "(",
    "5",
    ")",
    ",",
    "deepMomentarySag",
    "(",
    "6",
    ")",
    ",",
    "smallMomentarySpike",
    "(",
    "7",
    ")",
    ",",
    "largeMomentarySpike",
    "(",
    "8",
    ")",
    "}",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"The reason for the occurrence of the last transfer to UPS battery power. The variable is set to noTransfer(1) if there is no transfer yet. The variable is set to highLineVoltage(2) if the transfer to battery is caused by an over voltage greater than the high transfer voltage. The variable is set to brownout(3) if the duration of the outage is greater than five seconds and the line voltage is between 40 percent of the rated output voltage and the low transfer voltage. The variable is set to blackout(4) if the duration of the outage is greater than five seconds and the line voltage is between 40 percent of the rated output voltage and ground. The variable is set to smallMomentarySag(5) if the duration of the outage is less than five seconds and the line voltage is between 40 percent of the rated output voltage and the low transfer voltage. The variable is set to deepMomentarySag(6) if the duration of the outage is less than five seconds and the line voltage is between 40 percent of the rated output voltage and ground.\"",
    "::=",
    "{",
    "upsSmartInput",
    "5",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "noTransfer",
            1
          ],
          [
            "highLineVoltage",
            2
          ],
          [
            "brownout",
            3
          ],
          [
            "blackout",
            4
          ],
          [
            "smallMomentarySag",
            5
          ],
          [
            "deepMomentarySag",
            6
          ],
          [
            "smallMomentarySpike",
            7
          ],
          [
            "largeMomentarySpike",
            8
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "The reason for the occurrence of the last transfer to UPS battery power. The variable is set to noTransfer(1) if there is no transfer yet. The variable is set to highLineVoltage(2) if the transfer to battery is caused by an over voltage greater than the high transfer voltage. The variable is set to brownout(3) if the duration of the outage is greater than five seconds and the line voltage is between 40 percent of the rated output voltage and the low transfer voltage. The variable is set to blackout(4) if the duration of the outage is greater than five seconds and the line voltage is between 40 percent of the rated output voltage and ground. The variable is set to smallMomentarySag(5) if the duration of the outage is less than five seconds and the line voltage is between 40 percent of the rated output voltage and the low transfer voltage. The variable is set to deepMomentarySag(6) if the duration of the outage is less than five seconds and the line voltage is between 40 percent of the rated output voltage and ground."
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 2Reviewed vendor MIB copies in Fujitsu ServerView1 record · 1 source

Description 2

upsSmartInputLineFailCause · mandatoryReviewed vendor MIB copies in Fujitsu ServerView1 source

Status in source: mandatory.

Names: upsSmartInputLineFailCause

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "upsSmartInputLineFailCause",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "noTransfer",
    "(",
    "1",
    ")",
    ",",
    "highLineVoltage",
    "(",
    "2",
    ")",
    ",",
    "brownout",
    "(",
    "3",
    ")",
    ",",
    "blackout",
    "(",
    "4",
    ")",
    ",",
    "smallMomentarySag",
    "(",
    "5",
    ")",
    ",",
    "deepMomentarySag",
    "(",
    "6",
    ")",
    ",",
    "smallMomentarySpike",
    "(",
    "7",
    ")",
    ",",
    "largeMomentarySpike",
    "(",
    "8",
    ")",
    "}",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"The reason for the occurrence of the last transfer to UPS battery power. The variable is set to noTransfer(1) if there is no transfer yet. The variable is set to highLineVoltage(2) if the transfer to battery is caused by an over voltage greater than the high transfer voltage. The variable is set to brownout(3) if the duration of the outage is greater than five seconds and the line voltage is between 40% of the rated output voltage and the low transfer voltage. The variable is set to blackout(4) if the duration of the outage is greater than five seconds and the line voltage is between 40% of the rated output voltage and ground. The variable is set to smallMomentarySag(5) if the duration of the outage is less than five seconds and the line voltage is between 40% of the rated output voltage and the low transfer voltage. The variable is set to deepMomentarySag(6) if the duration of the outage is less than five seconds and the line voltage is between 40% of the rated output voltage and ground.\"",
    "::=",
    "{",
    "upsSmartInput",
    "5",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "noTransfer",
            1
          ],
          [
            "highLineVoltage",
            2
          ],
          [
            "brownout",
            3
          ],
          [
            "blackout",
            4
          ],
          [
            "smallMomentarySag",
            5
          ],
          [
            "deepMomentarySag",
            6
          ],
          [
            "smallMomentarySpike",
            7
          ],
          [
            "largeMomentarySpike",
            8
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "The reason for the occurrence of the last transfer to UPS battery power. The variable is set to noTransfer(1) if there is no transfer yet. The variable is set to highLineVoltage(2) if the transfer to battery is caused by an over voltage greater than the high transfer voltage. The variable is set to brownout(3) if the duration of the outage is greater than five seconds and the line voltage is between 40% of the rated output voltage and the low transfer voltage. The variable is set to blackout(4) if the duration of the outage is greater than five seconds and the line voltage is between 40% of the rated output voltage and ground. The variable is set to smallMomentarySag(5) if the duration of the outage is less than five seconds and the line voltage is between 40% of the rated output voltage and the low transfer voltage. The variable is set to deepMomentarySag(6) if the duration of the outage is less than five seconds and the line voltage is between 40% of the rated output voltage and ground."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.935)

An-Hsiang Tu

Siblings (4)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.935.1.1.1.3.2.1 upsSmartInputLineVoltage00
1.3.6.1.4.1.935.1.1.1.3.2.2 upsSmartInputMaxLineVoltage00
1.3.6.1.4.1.935.1.1.1.3.2.3 upsSmartInputMinLineVoltage00
1.3.6.1.4.1.935.1.1.1.3.2.4 upsSmartInputFrequency00