OID reference

upsBaseControlConserveBattery

1.3.6.1.4.1.935.1.1.1.6.1.1

Description

Setting this variable to turnUpsOffToConserveBattery(2) causes a UPS on battery to be put into 'sleep' mode. The UPS will turn back on when utility power is restored. Attempting to turn off a UPS that is not on battery will result in a badValue error. Setting this value to noTurnOffUps(1) has no effect. The value noTu…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.935.1.1.1.6.1 (upsBaseControl)
Node code
1
Node name
upsBaseControlConserveBattery
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.935.1.1.1.6.1.1
URN notation
urn:oid:1.3.6.1.4.1.935.1.1.1.6.1.1
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 935 1 1 1 6 1 1}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsControlp(6) upsBaseControl(1) upsBaseControlConserveBattery(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsControl(6) upsBaseControl(1) upsBaseControlConserveBattery(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ppc(935) products(1) hardware(1) ups(1) upsControlp(6) upsBaseControl(1) upsBaseControlConserveBattery(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ppc(935) products(1) hardware(1) ups(1) upsControl(6) upsBaseControl(1) upsBaseControlConserveBattery(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsControlp(6) upsBaseControl(1) upsBaseControlConserveBattery(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsControl(6) upsBaseControl(1) upsBaseControlConserveBattery(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ppc(935) products(1) hardware(1) ups(1) upsControlp(6) upsBaseControl(1) upsBaseControlConserveBattery(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ppc(935) products(1) hardware(1) ups(1) upsControl(6) upsBaseControl(1) upsBaseControlConserveBattery(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsControlp(6) upsBaseControl(1) upsBaseControlConserveBattery(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsControl(6) upsBaseControl(1) upsBaseControlConserveBattery(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ppc(935) products(1) hardware(1) ups(1) upsControlp(6) upsBaseControl(1) upsBaseControlConserveBattery(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ppc(935) products(1) hardware(1) ups(1) upsControl(6) upsBaseControl(1) upsBaseControlConserveBattery(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsControlp(6) upsBaseControl(1) upsBaseControlConserveBattery(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsControl(6) upsBaseControl(1) upsBaseControlConserveBattery(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) ppc(935) products(1) hardware(1) ups(1) upsControlp(6) upsBaseControl(1) upsBaseControlConserveBattery(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) ppc(935) products(1) hardware(1) ups(1) upsControl(6) upsBaseControl(1) upsBaseControlConserveBattery(1)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/935/1/1/1/6/1/1
  • /ISO/Identified-Organization/6/1/4/1/935/1/1/1/6/1/1
  • /ISO/3/6/1/4/1/935/1/1/1/6/1/1
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/935/1/hardware/ups/upsControlp/upsBaseControl/upsBaseControlConserveBattery
  • /iso/identified-organization/dod/internet/private/enterprise/935/1/hardware/ups/upsControl/upsBaseControl/upsBaseControlConserveBattery
  • /iso/identified-organization/dod/internet/private/enterprise/935/products/hardware/ups/upsControlp/upsBaseControl/upsBaseControlConserveBattery
  • /iso/identified-organization/dod/internet/private/enterprise/935/products/hardware/ups/upsControl/upsBaseControl/upsBaseControlConserveBattery
  • /iso/identified-organization/dod/internet/private/enterprise/ppc/1/hardware/ups/upsControlp/upsBaseControl/upsBaseControlConserveBattery
  • /iso/identified-organization/dod/internet/private/enterprise/ppc/1/hardware/ups/upsControl/upsBaseControl/upsBaseControlConserveBattery
  • /iso/identified-organization/dod/internet/private/enterprise/ppc/products/hardware/ups/upsControlp/upsBaseControl/upsBaseControlConserveBattery
  • /iso/identified-organization/dod/internet/private/enterprise/ppc/products/hardware/ups/upsControl/upsBaseControl/upsBaseControlConserveBattery
  • /iso/identified-organization/dod/internet/private/enterprises/935/1/hardware/ups/upsControlp/upsBaseControl/upsBaseControlConserveBattery
  • /iso/identified-organization/dod/internet/private/enterprises/935/1/hardware/ups/upsControl/upsBaseControl/upsBaseControlConserveBattery
  • /iso/identified-organization/dod/internet/private/enterprises/935/products/hardware/ups/upsControlp/upsBaseControl/upsBaseControlConserveBattery
  • /iso/identified-organization/dod/internet/private/enterprises/935/products/hardware/ups/upsControl/upsBaseControl/upsBaseControlConserveBattery
  • /iso/identified-organization/dod/internet/private/enterprises/ppc/1/hardware/ups/upsControlp/upsBaseControl/upsBaseControlConserveBattery
  • /iso/identified-organization/dod/internet/private/enterprises/ppc/1/hardware/ups/upsControl/upsBaseControl/upsBaseControlConserveBattery
  • /iso/identified-organization/dod/internet/private/enterprises/ppc/products/hardware/ups/upsControlp/upsBaseControl/upsBaseControlConserveBattery
  • /iso/identified-organization/dod/internet/private/enterprises/ppc/products/hardware/ups/upsControl/upsBaseControl/upsBaseControlConserveBattery
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — Reviewed vendor MIB copies in Fujitsu ServerView

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory

Variant 2 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Common and standard MIB copies (LibreNMS/Observium Community), and others

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory

Enumerated values

Numbers refer to source variants above. Each value is shown only for variants that define it.

ValueNameSource variants
1noTurnOffUps1, 2
2turnUpsOffToConserveBattery1, 2
3turnUpsOffToConserveBatteryDelay2

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.935.1.1.1.6.1.1.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

upsBaseControlConserveBattery · mandatory

upsBaseControlConserveBattery OBJECT-TYPE
	SYNTAX INTEGER  {
		noTurnOffUps(1),
		turnUpsOffToConserveBattery(2)
	}
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Setting this variable to turnUpsOffToConserveBattery(2)
		 causes a UPS on battery to be put into 'sleep' mode.  The
		 UPS will turn back on when utility power is restored.
		 Attempting to turn off a UPS that is not on battery will
		 result in a badValue error.

		 Setting this value to noTurnOffUps(1) has no
		 effect.

		 The value noTurnOffUps(1) will always be returned
		 when the variable is read."
::= { upsBaseControl 1 }

upsBaseControlConserveBattery · mandatory

upsBaseControlConserveBattery OBJECT-TYPE
        SYNTAX INTEGER {
                        noTurnOffUps(1),
                        turnUpsOffToConserveBattery(2),
                        turnUpsOffToConserveBatteryDelay(3) }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Setting this variable to turnUpsOffToConserveBattery(2)
                causes a UPS on battery to be put into 'sleep' mode immediately.
                The (10) means suspending time(10 minutes) before turn off UPS.
                UPS will turn back on when utility power is restored.
                Attempting to turn off a UPS that is not on battery will
                result in a badValue error.
                                
                Setting this value to noTurnOffUps(1) has no
                effect.
                                
                The value noTurnOffUps(1) will always be returned
                when the variable is read."
   ::= { upsBaseControl 1 }

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Setting this variable to turnUpsOffToConserveBattery(2) causes a UPS on battery to be put into 'sleep' mode. The UPS will turn back on when utility power is restored. Attempting to turn off a UPS that is not on battery will result in a badValue error. Setting this value to noTurnOffUps(1) has no effect. The value noTurnOffUps(1) will always be returned when the variable is read.

Sources for this description

Reviewed vendor MIB copies in Fujitsu ServerView

See 1 matching source record

Description 2

Setting this variable to turnUpsOffToConserveBattery(2) causes a UPS on battery to be put into 'sleep' mode immediately. The (10) means suspending time(10 minutes) before turn off UPS. UPS will turn back on when utility power is restored. Attempting to turn off a UPS that is not on battery will result in a badValue error. Setting this value to noTurnOffUps(1) has no effect. The value noTurnOffUps(1) will always be returned when the variable is read.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Common and standard MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies

See 1 matching source record

Evidence

Source records

2 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1Reviewed vendor MIB copies in Fujitsu ServerView1 record · 1 source

Description 1

upsBaseControlConserveBattery · mandatoryReviewed vendor MIB copies in Fujitsu ServerView1 source

Status in source: mandatory.

Names: upsBaseControlConserveBattery

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "upsBaseControlConserveBattery",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "noTurnOffUps",
    "(",
    "1",
    ")",
    ",",
    "turnUpsOffToConserveBattery",
    "(",
    "2",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"Setting this variable to turnUpsOffToConserveBattery(2) causes a UPS on battery to be put into 'sleep' mode. The UPS will turn back on when utility power is restored. Attempting to turn off a UPS that is not on battery will result in a badValue error. Setting this value to noTurnOffUps(1) has no effect. The value noTurnOffUps(1) will always be returned when the variable is read.\"",
    "::=",
    "{",
    "upsBaseControl",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "noTurnOffUps",
            1
          ],
          [
            "turnUpsOffToConserveBattery",
            2
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "Setting this variable to turnUpsOffToConserveBattery(2) causes a UPS on battery to be put into 'sleep' mode. The UPS will turn back on when utility power is restored. Attempting to turn off a UPS that is not on battery will result in a badValue error. Setting this value to noTurnOffUps(1) has no effect. The value noTurnOffUps(1) will always be returned when the variable is read."
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 2Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Common and standard MIB copies (LibreNMS/Observium Community), and others1 record · 4 sources

Description 2

upsBaseControlConserveBattery · mandatoryMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Common and standard MIB copies (LibreNMS/Observium Community), and others4 sources

Status in source: mandatory.

Names: upsBaseControlConserveBattery

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "upsBaseControlConserveBattery",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "noTurnOffUps",
    "(",
    "1",
    ")",
    ",",
    "turnUpsOffToConserveBattery",
    "(",
    "2",
    ")",
    ",",
    "turnUpsOffToConserveBatteryDelay",
    "(",
    "3",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"Setting this variable to turnUpsOffToConserveBattery(2) causes a UPS on battery to be put into 'sleep' mode immediately. The (10) means suspending time(10 minutes) before turn off UPS. UPS will turn back on when utility power is restored. Attempting to turn off a UPS that is not on battery will result in a badValue error. Setting this value to noTurnOffUps(1) has no effect. The value noTurnOffUps(1) will always be returned when the variable is read.\"",
    "::=",
    "{",
    "upsBaseControl",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "noTurnOffUps",
            1
          ],
          [
            "turnUpsOffToConserveBattery",
            2
          ],
          [
            "turnUpsOffToConserveBatteryDelay",
            3
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "Setting this variable to turnUpsOffToConserveBattery(2) causes a UPS on battery to be put into 'sleep' mode immediately. The (10) means suspending time(10 minutes) before turn off UPS. UPS will turn back on when utility power is restored. Attempting to turn off a UPS that is not on battery will result in a badValue error. Setting this value to noTurnOffUps(1) has no effect. The value noTurnOffUps(1) will always be returned when the variable is read."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.935)

An-Hsiang Tu