upsSmartTestRuntimeCalibration

1.3.6.1.4.1.935.1.1.1.7.2.6

Description

Setting this variable to performCalibration(2) causes the UPS to discharge to calibrate the UPS. The test will only start if the battery capacity is 100 percent. The test runs until capacity is less than 25 percent. Setting this variable to cancelCurrentCalibration(3) after setting performCalibration(2) will cancel th…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.935.1.1.1.7.2 (upsSmartTest)
Node code
6
Node name
upsSmartTestRuntimeCalibration
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.935.1.1.1.7.2.6
URN notation
urn:oid:1.3.6.1.4.1.935.1.1.1.7.2.6
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 935 1 1 1 7 2 6}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsTestp(7) upsSmartTest(2) upsSmartTestRuntimeCalibration(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsTest(7) upsSmartTest(2) upsSmartTestRuntimeCalibration(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ppc(935) products(1) hardware(1) ups(1) upsTestp(7) upsSmartTest(2) upsSmartTestRuntimeCalibration(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ppc(935) products(1) hardware(1) ups(1) upsTest(7) upsSmartTest(2) upsSmartTestRuntimeCalibration(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsTestp(7) upsSmartTest(2) upsSmartTestRuntimeCalibration(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsTest(7) upsSmartTest(2) upsSmartTestRuntimeCalibration(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ppc(935) products(1) hardware(1) ups(1) upsTestp(7) upsSmartTest(2) upsSmartTestRuntimeCalibration(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ppc(935) products(1) hardware(1) ups(1) upsTest(7) upsSmartTest(2) upsSmartTestRuntimeCalibration(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsTestp(7) upsSmartTest(2) upsSmartTestRuntimeCalibration(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsTest(7) upsSmartTest(2) upsSmartTestRuntimeCalibration(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ppc(935) products(1) hardware(1) ups(1) upsTestp(7) upsSmartTest(2) upsSmartTestRuntimeCalibration(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ppc(935) products(1) hardware(1) ups(1) upsTest(7) upsSmartTest(2) upsSmartTestRuntimeCalibration(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsTestp(7) upsSmartTest(2) upsSmartTestRuntimeCalibration(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppc(935) products(1) hardware(1) ups(1) upsTest(7) upsSmartTest(2) upsSmartTestRuntimeCalibration(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) ppc(935) products(1) hardware(1) ups(1) upsTestp(7) upsSmartTest(2) upsSmartTestRuntimeCalibration(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) ppc(935) products(1) hardware(1) ups(1) upsTest(7) upsSmartTest(2) upsSmartTestRuntimeCalibration(6)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/935/1/1/1/7/2/6
  • /ISO/Identified-Organization/6/1/4/1/935/1/1/1/7/2/6
  • /ISO/3/6/1/4/1/935/1/1/1/7/2/6
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/935/1/hardware/ups/upsTestp/upsSmartTest/upsSmartTestRuntimeCalibration
  • /iso/identified-organization/dod/internet/private/enterprise/935/1/hardware/ups/upsTest/upsSmartTest/upsSmartTestRuntimeCalibration
  • /iso/identified-organization/dod/internet/private/enterprise/935/products/hardware/ups/upsTestp/upsSmartTest/upsSmartTestRuntimeCalibration
  • /iso/identified-organization/dod/internet/private/enterprise/935/products/hardware/ups/upsTest/upsSmartTest/upsSmartTestRuntimeCalibration
  • /iso/identified-organization/dod/internet/private/enterprise/ppc/1/hardware/ups/upsTestp/upsSmartTest/upsSmartTestRuntimeCalibration
  • /iso/identified-organization/dod/internet/private/enterprise/ppc/1/hardware/ups/upsTest/upsSmartTest/upsSmartTestRuntimeCalibration
  • /iso/identified-organization/dod/internet/private/enterprise/ppc/products/hardware/ups/upsTestp/upsSmartTest/upsSmartTestRuntimeCalibration
  • /iso/identified-organization/dod/internet/private/enterprise/ppc/products/hardware/ups/upsTest/upsSmartTest/upsSmartTestRuntimeCalibration
  • /iso/identified-organization/dod/internet/private/enterprises/935/1/hardware/ups/upsTestp/upsSmartTest/upsSmartTestRuntimeCalibration
  • /iso/identified-organization/dod/internet/private/enterprises/935/1/hardware/ups/upsTest/upsSmartTest/upsSmartTestRuntimeCalibration
  • /iso/identified-organization/dod/internet/private/enterprises/935/products/hardware/ups/upsTestp/upsSmartTest/upsSmartTestRuntimeCalibration
  • /iso/identified-organization/dod/internet/private/enterprises/935/products/hardware/ups/upsTest/upsSmartTest/upsSmartTestRuntimeCalibration
  • /iso/identified-organization/dod/internet/private/enterprises/ppc/1/hardware/ups/upsTestp/upsSmartTest/upsSmartTestRuntimeCalibration
  • /iso/identified-organization/dod/internet/private/enterprises/ppc/1/hardware/ups/upsTest/upsSmartTest/upsSmartTestRuntimeCalibration
  • /iso/identified-organization/dod/internet/private/enterprises/ppc/products/hardware/ups/upsTestp/upsSmartTest/upsSmartTestRuntimeCalibration
  • /iso/identified-organization/dod/internet/private/enterprises/ppc/products/hardware/ups/upsTest/upsSmartTest/upsSmartTestRuntimeCalibration
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory

Enumerated values

ValueName
1noPerformCalibration
2performCalibration
3cancelCurrentCalibration

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.935.1.1.1.7.2.6.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

upsSmartTestRuntimeCalibration · mandatory

upsSmartTestRuntimeCalibration OBJECT-TYPE
        SYNTAX INTEGER {
                        noPerformCalibration(1),
                        performCalibration(2),
                        cancelCurrentCalibration(3) }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Setting this variable to performCalibration(2) causes
                the UPS to discharge to calibrate the UPS.
                The test will only start if the battery capacity is 100 percent.
                The test runs until capacity is less than 25 percent.
                                
                Setting this variable to cancelCurrentCalibration(3)
                after setting performCalibration(2) will cancel the
                current discharge.
                                
                Setting this variable to noPerformCalibration(1)
                will have no effect.
                                
                The value noPerformCalibration(1) will always be returned
                when the variable is read.
                                
                The result of the calibration will be saved in
                upsSmartTestCalibrationResult."
   ::= { upsSmartTest 6 }

upsSmartTestRuntimeCalibration · mandatory

upsSmartTestRuntimeCalibration OBJECT-TYPE
	SYNTAX INTEGER  {
		noPerformCalibration(1),
		performCalibration(2),
		cancelCurrentCalibration(3)
	}
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Setting this variable to performCalibration(2) causes
		 the UPS to discharge to calibrate the UPS.
		 The test will only start if the battery capacity is 100%.
		 The test runs until capacity is less than 25%.

		 Setting this variable to cancelCurrentCalibration(3)
		 after setting performCalibration(2) will cancel the
		 current discharge.

		 Setting this variable to noPerformCalibration(1)
		 will have no effect.

		 The value noPerformCalibration(1) will always be returned
		 when the variable is read.

		 The result of the calibration will be saved in
		 upsSmartTestCalibrationResult."
	::= { upsSmartTest 6 }

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Setting this variable to performCalibration(2) causes the UPS to discharge to calibrate the UPS. The test will only start if the battery capacity is 100 percent. The test runs until capacity is less than 25 percent. Setting this variable to cancelCurrentCalibration(3) after setting performCalibration(2) will cancel the current discharge. Setting this variable to noPerformCalibration(1) will have no effect. The value noPerformCalibration(1) will always be returned when the variable is read. The result of the calibration will be saved in upsSmartTestCalibrationResult.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Common and standard MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies

See 1 matching source record

Description 2

Setting this variable to performCalibration(2) causes the UPS to discharge to calibrate the UPS. The test will only start if the battery capacity is 100%. The test runs until capacity is less than 25%. Setting this variable to cancelCurrentCalibration(3) after setting performCalibration(2) will cancel the current discharge. Setting this variable to noPerformCalibration(1) will have no effect. The value noPerformCalibration(1) will always be returned when the variable is read. The result of the calibration will be saved in upsSmartTestCalibrationResult.

Sources for this description

Reviewed vendor MIB copies in Fujitsu ServerView

See 1 matching source record

Evidence

Source records

2 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Common and standard MIB copies (LibreNMS/Observium Community), and others1 record · 4 sources

Description 1

upsSmartTestRuntimeCalibration · mandatoryMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Common and standard MIB copies (LibreNMS/Observium Community), and others4 sources

Status in source: mandatory.

Names: upsSmartTestRuntimeCalibration

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "upsSmartTestRuntimeCalibration",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "noPerformCalibration",
    "(",
    "1",
    ")",
    ",",
    "performCalibration",
    "(",
    "2",
    ")",
    ",",
    "cancelCurrentCalibration",
    "(",
    "3",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"Setting this variable to performCalibration(2) causes the UPS to discharge to calibrate the UPS. The test will only start if the battery capacity is 100 percent. The test runs until capacity is less than 25 percent. Setting this variable to cancelCurrentCalibration(3) after setting performCalibration(2) will cancel the current discharge. Setting this variable to noPerformCalibration(1) will have no effect. The value noPerformCalibration(1) will always be returned when the variable is read. The result of the calibration will be saved in upsSmartTestCalibrationResult.\"",
    "::=",
    "{",
    "upsSmartTest",
    "6",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "noPerformCalibration",
            1
          ],
          [
            "performCalibration",
            2
          ],
          [
            "cancelCurrentCalibration",
            3
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "Setting this variable to performCalibration(2) causes the UPS to discharge to calibrate the UPS. The test will only start if the battery capacity is 100 percent. The test runs until capacity is less than 25 percent. Setting this variable to cancelCurrentCalibration(3) after setting performCalibration(2) will cancel the current discharge. Setting this variable to noPerformCalibration(1) will have no effect. The value noPerformCalibration(1) will always be returned when the variable is read. The result of the calibration will be saved in upsSmartTestCalibrationResult."
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 2Reviewed vendor MIB copies in Fujitsu ServerView1 record · 1 source

Description 2

upsSmartTestRuntimeCalibration · mandatoryReviewed vendor MIB copies in Fujitsu ServerView1 source

Status in source: mandatory.

Names: upsSmartTestRuntimeCalibration

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "upsSmartTestRuntimeCalibration",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "noPerformCalibration",
    "(",
    "1",
    ")",
    ",",
    "performCalibration",
    "(",
    "2",
    ")",
    ",",
    "cancelCurrentCalibration",
    "(",
    "3",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"Setting this variable to performCalibration(2) causes the UPS to discharge to calibrate the UPS. The test will only start if the battery capacity is 100%. The test runs until capacity is less than 25%. Setting this variable to cancelCurrentCalibration(3) after setting performCalibration(2) will cancel the current discharge. Setting this variable to noPerformCalibration(1) will have no effect. The value noPerformCalibration(1) will always be returned when the variable is read. The result of the calibration will be saved in upsSmartTestCalibrationResult.\"",
    "::=",
    "{",
    "upsSmartTest",
    "6",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "noPerformCalibration",
            1
          ],
          [
            "performCalibration",
            2
          ],
          [
            "cancelCurrentCalibration",
            3
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "Setting this variable to performCalibration(2) causes the UPS to discharge to calibrate the UPS. The test will only start if the battery capacity is 100%. The test runs until capacity is less than 25%. Setting this variable to cancelCurrentCalibration(3) after setting performCalibration(2) will cancel the current discharge. Setting this variable to noPerformCalibration(1) will have no effect. The value noPerformCalibration(1) will always be returned when the variable is read. The result of the calibration will be saved in upsSmartTestCalibrationResult."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.935)

An-Hsiang Tu

Siblings (7)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.935.1.1.1.7.2.1 upsSmartTestDiagnosticSchedule00
1.3.6.1.4.1.935.1.1.1.7.2.2 upsSmartTestDiagnostics00
1.3.6.1.4.1.935.1.1.1.7.2.3 upsSmartTestDiagnosticsResults00
1.3.6.1.4.1.935.1.1.1.7.2.4 upsSmartTestLastDiagnosticsDate00
1.3.6.1.4.1.935.1.1.1.7.2.5 upsSmartTestIndicators00
1.3.6.1.4.1.935.1.1.1.7.2.7 upsSmartTestCalibrationResults00
1.3.6.1.4.1.935.1.1.1.7.2.8 upsSmartTestCalibrationDate00