upsEBatteryStatus

1.3.6.1.4.1.935.10.1.1.3.1

Description

The status of UPS battery, a value of batteryLow indicates that the battery-low status bit has been set from device. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is mandatoryly absent…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.935.10.1.1.3 (upsEBatterySystem)
Node code
1
Node name
upsEBatteryStatus
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.935.10.1.1.3.1
URN notation
urn:oid:1.3.6.1.4.1.935.10.1.1.3.1
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 935 10 1 1 3 1}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ppc(935) device(10) upsAgent(1) upsE(1) upsEBatterySystem(3) upsEBatteryStatus(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ppc(935) device(10) upsAgent(1) upsE(1) upsEBatterySystem(3) upsEBatteryStatus(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppc(935) device(10) upsAgent(1) upsE(1) upsEBatterySystem(3) upsEBatteryStatus(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ppc(935) device(10) upsAgent(1) upsE(1) upsEBatterySystem(3) upsEBatteryStatus(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ppc(935) device(10) upsAgent(1) upsE(1) upsEBatterySystem(3) upsEBatteryStatus(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ppc(935) device(10) upsAgent(1) upsE(1) upsEBatterySystem(3) upsEBatteryStatus(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppc(935) device(10) upsAgent(1) upsE(1) upsEBatterySystem(3) upsEBatteryStatus(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) ppc(935) device(10) upsAgent(1) upsE(1) upsEBatterySystem(3) upsEBatteryStatus(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ppc(935) device(10) upsAgent(1) upsE(1) upsEBatterySystem(3) upsEBatteryStatus(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ppc(935) device(10) upsAgent(1) upsE(1) upsEBatterySystem(3) upsEBatteryStatus(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppc(935) device(10) upsAgent(1) upsE(1) upsEBatterySystem(3) upsEBatteryStatus(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ppc(935) device(10) upsAgent(1) upsE(1) upsEBatterySystem(3) upsEBatteryStatus(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) ppc(935) device(10) upsAgent(1) upsE(1) upsEBatterySystem(3) upsEBatteryStatus(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) ppc(935) device(10) upsAgent(1) upsE(1) upsEBatterySystem(3) upsEBatteryStatus(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ppc(935) device(10) upsAgent(1) upsE(1) upsEBatterySystem(3) upsEBatteryStatus(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ppc(935) device(10) upsAgent(1) upsE(1) upsEBatterySystem(3) upsEBatteryStatus(1)}
OID-IRI notation
  • /1/3/6/1/4/1/935/10/1/1/3/1
  • /ISO/Identified-Organization/6/1/4/1/935/10/1/1/3/1
  • /ISO/3/6/1/4/1/935/10/1/1/3/1
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/935/device/upsAgent/upsE/upsEBatterySystem/upsEBatteryStatus
  • /iso/identified-organization/dod/internet/private/enterprise/ppc/device/upsAgent/upsE/upsEBatterySystem/upsEBatteryStatus
  • /iso/identified-organization/dod/internet/private/enterprises/935/device/upsAgent/upsE/upsEBatterySystem/upsEBatteryStatus
  • /iso/identified-organization/dod/internet/private/enterprises/ppc/device/upsAgent/upsE/upsEBatterySystem/upsEBatteryStatus
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/935/device/upsAgent/upsE/upsEBatterySystem/upsEBatteryStatus
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/ppc/device/upsAgent/upsE/upsEBatterySystem/upsEBatteryStatus
  • /iso/identified-organization/dod/internet/private/vendor-objects/935/device/upsAgent/upsE/upsEBatterySystem/upsEBatteryStatus
  • /iso/identified-organization/dod/internet/private/vendor-objects/ppc/device/upsAgent/upsE/upsEBatterySystem/upsEBatteryStatus
  • /iso/org/dod/internet/private/enterprise/935/device/upsAgent/upsE/upsEBatterySystem/upsEBatteryStatus
  • /iso/org/dod/internet/private/enterprise/ppc/device/upsAgent/upsE/upsEBatterySystem/upsEBatteryStatus
  • /iso/org/dod/internet/private/enterprises/935/device/upsAgent/upsE/upsEBatterySystem/upsEBatteryStatus
  • /iso/org/dod/internet/private/enterprises/ppc/device/upsAgent/upsE/upsEBatterySystem/upsEBatteryStatus
  • /iso/org/dod/internet/private/ldap-enterprise/935/device/upsAgent/upsE/upsEBatterySystem/upsEBatteryStatus
  • /iso/org/dod/internet/private/ldap-enterprise/ppc/device/upsAgent/upsE/upsEBatterySystem/upsEBatteryStatus
  • /iso/org/dod/internet/private/vendor-objects/935/device/upsAgent/upsE/upsEBatterySystem/upsEBatteryStatus
  • /iso/org/dod/internet/private/vendor-objects/ppc/device/upsAgent/upsE/upsEBatterySystem/upsEBatteryStatus
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
mandatory

Enumerated values

ValueName
1unknown
2batteryNormal
3batteryLow
4batteryDepleted
5batteryDischarging
6batteryFailure

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.935.10.1.1.3.1.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

upsEBatteryStatus · mandatory

upsEBatteryStatus	OBJECT-TYPE	
		SYNTAX			INTEGER  { unknown ( 1 ) , batteryNormal ( 2 ) , batteryLow ( 3 ) , 
                                               batteryDepleted ( 4 ) , batteryDischarging ( 5 ) , batteryFailure ( 6 ) } 
		ACCESS		read-only
		STATUS			mandatory
		DESCRIPTION		" The status of UPS battery, a value of batteryLow indicates
                                that the battery-low status bit has been set from device. 
                                A value of batteryDepleted indicates that the UPS will be 
                                unable to sustain the present load when and if the utility 
                                power is lost (including the possibility that the  utility 
                                power is mandatoryly absent and the UPS is unable to sustain
                                the output)"
		::=  {  upsEBatterySystem  1  }

upsEBatteryStatus · mandatory

upsEBatteryStatus	OBJECT-TYPE	
		SYNTAX			INTEGER  { unknown ( 1 ) , batteryNormal ( 2 ) , batteryLow ( 3 ) , 
                                               batteryDepleted ( 4 ) , batteryDischarging ( 5 ) , batteryFailure ( 6 ) } 
		ACCESS		read-only
		STATUS			mandatory
		DESCRIPTION		" The status of UPS battery, a value of batteryLow indicates
                                that the battery-low status bit has been set from device. 
                                A value of batteryDepleted indicates that the UPS will be 
                                unable to sustain the present load when and if the utility 
                                power is lost (including the possibility that the  utility 
                                power is mandatoryly absent and the UPS is unable to sustain
                                the output)"
		::=  {  upsEBatterySystem  1  }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

The status of UPS battery, a value of batteryLow indicates that the battery-low status bit has been set from device. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is mandatoryly absent and the UPS is unable to sustain the output)

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 2 sources

Description 1

upsEBatteryStatus · mandatoryMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)2 sources

Status in source: mandatory.

Names: upsEBatteryStatus

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "upsEBatteryStatus",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "unknown",
    "(",
    "1",
    ")",
    ",",
    "batteryNormal",
    "(",
    "2",
    ")",
    ",",
    "batteryLow",
    "(",
    "3",
    ")",
    ",",
    "batteryDepleted",
    "(",
    "4",
    ")",
    ",",
    "batteryDischarging",
    "(",
    "5",
    ")",
    ",",
    "batteryFailure",
    "(",
    "6",
    ")",
    "}",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\" The status of UPS battery, a value of batteryLow indicates that the battery-low status bit has been set from device. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is mandatoryly absent and the UPS is unable to sustain the output)\"",
    "::=",
    "{",
    "upsEBatterySystem",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "unknown",
            1
          ],
          [
            "batteryNormal",
            2
          ],
          [
            "batteryLow",
            3
          ],
          [
            "batteryDepleted",
            4
          ],
          [
            "batteryDischarging",
            5
          ],
          [
            "batteryFailure",
            6
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "The status of UPS battery, a value of batteryLow indicates that the battery-low status bit has been set from device. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is mandatoryly absent and the UPS is unable to sustain the output)"
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.935)

An-Hsiang Tu

Siblings (11)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.935.10.1.1.3.2 upsESecondsOnBattery00
1.3.6.1.4.1.935.10.1.1.3.3 upsEBatteryEstimatedMinutesRemaining00
1.3.6.1.4.1.935.10.1.1.3.4 upsEBatteryEstimatedChargeRemaining00
1.3.6.1.4.1.935.10.1.1.3.5 upsEPositiveBatteryVoltage00
1.3.6.1.4.1.935.10.1.1.3.6 upsENegativeBatteryVoltage00
1.3.6.1.4.1.935.10.1.1.3.7 upsEBatteryCellNumber00
1.3.6.1.4.1.935.10.1.1.3.8 upsEBatteryTemperature00
1.3.6.1.4.1.935.10.1.1.3.9 upsEBatteryLastReplacedDate00
1.3.6.1.4.1.935.10.1.1.3.10 upsEBatteryABMStatus00
1.3.6.1.4.1.935.10.1.1.3.11 upsEChargerModulesNum00
1.3.6.1.4.1.935.10.1.1.3.12 upsEChargerModulesTable19