Status in source: mandatory.
Names: matConfStsIpvVoltLowLoss
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"matConfStsIpvVoltLowLoss",
"OBJECT-TYPE",
"SYNTAX",
"NonNegativeInteger",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"STS module Inverter IPV low Loss Volt, the unit is 0.1 volt. This value depends on matConfInvSysOutputVolt, the least significant digit must be zero, see table: matConfInvSysOutputVolt(0.1V) Range(0.1V) 1100 890-1050, 1150 930-1100, 1200 1000-1140, 2080 1760-1980, 2200 1760-2090, 2300 1850-2180, 2400 1930-2280\"",
"::=",
"{",
"matConfig",
"14",
"}"
],
"syntax_tree": [
[
"row",
"NonNegativeInteger"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"STS module Inverter IPV low Loss Volt, the unit is 0.1 volt. This value depends on matConfInvSysOutputVolt, the least significant digit must be zero, see table: matConfInvSysOutputVolt(0.1V) Range(0.1V) 1100 890-1050, 1150 930-1100, 1200 1000-1140, 2080 1760-1980, 2200 1760-2090, 2300 1850-2180, 2400 1930-2280"
],
null,
null,
null,
null
]
}