Description 1
Compressor 1 circuit 2 ON
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.9839.2.1.1.103
Compressor 1 circuit 2 ON
Identification
{1 3 6 1 4 1 9839 2 1 1 103}
Definitions may combine these properties differently.
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.9839.2.1.1.103.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 3 distinct definitions; some records may not include a definition.
c21-on OBJECT-TYPE
SYNTAX Integer32 (0..1)
UNITS "N/A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Compressor 1 circuit 2 ON"
::= { digitalObjects 103 }mal_b7 OBJECT-TYPE
SYNTAX Integer32 (0..1)
UNITS "N/A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "b7 probe broken or not connected"
::= { digitalObjects 103 }en_high_refresh OBJECT-TYPE
SYNTAX Integer32 (0..1)
UNITS "N/A"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable high-frequency refresh"
DEFVAL { 0 }
::= { digitalObjects 103 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
Compressor 1 circuit 2 ON
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 2
b7 probe broken or not connected
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 3
Enable high-frequency refresh
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: c21-on
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"c21-on",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"1",
")",
"UNITS",
[
"literal",
"224e2f4122"
],
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Compressor 1 circuit 2 ON\"",
"::=",
"{",
"digitalObjects",
"103",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
1
]
]
]
],
[
"UNITS",
"N/A"
],
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Compressor 1 circuit 2 ON"
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: KELVIN-pCOWeb-Chiller-MIB
See published definition above
{'SNMPv2-MIB': ['sysContact', 'sysName', 'sysLocation'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP']}Related source files and packages:
Same file in Observium Community.
Status in source: current.
Names: mal_b7
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"mal_b7",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"1",
")",
"UNITS",
[
"literal",
"224e2f4122"
],
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"b7 probe broken or not connected\"",
"::=",
"{",
"digitalObjects",
"103",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
1
]
]
]
],
[
"UNITS",
"N/A"
],
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"b7 probe broken or not connected"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: CAREL-mod_ch-MIB
See published definition above
{'SNMPv2-MIB': ['sysContact', 'sysName', 'sysLocation'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY'], 'SNMPv2-CONF': ['OBJECT-GROUP']}Status in source: current.
Names: en_high_refresh
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"en_high_refresh",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"1",
")",
"UNITS",
[
"literal",
"224e2f4122"
],
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Enable high-frequency refresh\"",
"DEFVAL",
"{",
"0",
"}",
"::=",
"{",
"digitalObjects",
"103",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
1
]
]
]
],
[
"UNITS",
"N/A"
],
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Enable high-frequency refresh"
],
null,
null,
null,
[
"DEFVAL",
0
]
]
}Vendor MIB copy from the Observium Community archive.
Module: CAREL-mastercase-MIB
See published definition above
{'SNMPv2-MIB': ['sysContact', 'sysName', 'sysLocation'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY'], 'SNMPv2-CONF': ['OBJECT-GROUP']}Registration