Description 1
Recirculated air humidity calibration
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.9839.2.1.2.54
Recirculated air humidity calibration
Identification
{1 3 6 1 4 1 9839 2 1 2 54}
Definitions may combine these properties differently.
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.9839.2.1.2.54.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
tar_umid_amb OBJECT-TYPE
SYNTAX Integer32 (20..130)
UNITS "°C x10"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Recirculated air humidity calibration"
DEFVAL { 0 }
::= { analogObjects 54 }r24 OBJECT-TYPE
SYNTAX Integer32 (0..100)
UNITS "- x10"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Negative gain for setpoint compensation."
DEFVAL { 40 }
::= { analogObjects 54 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
Recirculated air humidity calibration
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 2
Negative gain for setpoint compensation.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: tar_umid_amb
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tar_umid_amb",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"20",
".",
".",
"130",
")",
"UNITS",
[
"literal",
"22c2b0432078313022"
],
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Recirculated air humidity calibration\"",
"DEFVAL",
"{",
"0",
"}",
"::=",
"{",
"analogObjects",
"54",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
20,
130
]
]
]
],
[
"UNITS",
"°C x10"
],
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Recirculated air humidity calibration"
],
null,
null,
null,
[
"DEFVAL",
0
]
]
}Vendor MIB copy from the Observium Community archive.
Module: CAREL-rtop_pco-MIB
See published definition above
{'SNMPv2-MIB': ['sysContact', 'sysName', 'sysLocation'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY'], 'SNMPv2-CONF': ['OBJECT-GROUP']}Related source files and packages:
Status in source: current.
Names: r24
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"r24",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"100",
")",
"UNITS",
[
"literal",
"222d2078313022"
],
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Negative gain for setpoint compensation.\"",
"DEFVAL",
"{",
"40",
"}",
"::=",
"{",
"analogObjects",
"54",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
100
]
]
]
],
[
"UNITS",
"- x10"
],
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Negative gain for setpoint compensation."
],
null,
null,
null,
[
"DEFVAL",
40
]
]
}Vendor MIB copy from the Observium Community archive.
Module: CAREL-aria-MIB
See published definition above
{'SNMPv2-MIB': ['sysContact', 'sysName', 'sysLocation'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY'], 'SNMPv2-CONF': ['OBJECT-GROUP']}Registration