OID reference

delay-Freecooling-Thermal-Exclusion

1.3.6.1.4.1.9839.2.1.3.57

Description

Low part, operating hours compressor 2

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.9839.2.1.3 (integerObjects)
Node code
57
Node names
  • delay-Freecooling-Thermal-Exclusion
  • min_off_time_c2
  • modello_valvola
  • h7
  • fin_rampa_n3v
  • hour_l_comp2
  • temp_al_del_ad
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.9839.2.1.3.57
URN notation
urn:oid:1.3.6.1.4.1.9839.2.1.3.57
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 9839 2 1 3 57}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) integerObjects(3) delay-Freecooling-Thermal-Exclusion(57)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) integerObjects(3) h7(57)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) integerObjects(3) delay-Freecooling-Thermal-Exclusion(57)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) integerObjects(3) h7(57)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) integerObjects(3) delay-Freecooling-Thermal-Exclusion(57)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) integerObjects(3) h7(57)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) integerObjects(3) delay-Freecooling-Thermal-Exclusion(57)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) integerObjects(3) h7(57)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uncdz-MIB(1) integerObjects(3) delay-Freecooling-Thermal-Exclusion(57)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uncdz-MIB(1) integerObjects(3) h7(57)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) mcellaMIB(1) integerObjects(3) delay-Freecooling-Thermal-Exclusion(57)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) mcellaMIB(1) integerObjects(3) h7(57)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) mastercaseMIB(1) integerObjects(3) delay-Freecooling-Thermal-Exclusion(57)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) mastercaseMIB(1) integerObjects(3) h7(57)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) mastercellasplitMIB(1) integerObjects(3) delay-Freecooling-Thermal-Exclusion(57)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) mastercellasplitMIB(1) integerObjects(3) h7(57)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/9839/2/1/3/57
  • /ISO/Identified-Organization/6/1/4/1/9839/2/1/3/57
  • /ISO/3/6/1/4/1/9839/2/1/3/57
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/delay-Freecooling-Thermal-Exclusion
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/min_off_time_c2
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/modello_valvola
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/h7
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/fin_rampa_n3v
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/hour_l_comp2
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/temp_al_del_ad
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/integerObjects/delay-Freecooling-Thermal-Exclusion
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/integerObjects/min_off_time_c2
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/integerObjects/modello_valvola
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/integerObjects/h7
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/integerObjects/fin_rampa_n3v
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/integerObjects/hour_l_comp2
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/integerObjects/temp_al_del_ad
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/dap4-alMIB/integerObjects/delay-Freecooling-Thermal-Exclusion
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/dap4-alMIB/integerObjects/min_off_time_c2
  • Additional combinations skipped.

SNMP properties

Value type
Integer32
Units
N/A, sec, %, min
Maximum access defined by MIB
read-only, read-write
Status in MIB
current
Default value
60, 100, 120, 0, 1

Definitions may combine these properties differently.

Compare 7 source variants

Variant 1 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-only
Status in MIB
current
Allowed ranges
-32767–32767

Variant 2 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
sec
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
60
Allowed ranges
0–900

Variant 3 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-write
Status in MIB
current
Allowed ranges
0–999

Variant 4 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
%
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
100
Allowed ranges
0–100

Variant 5 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
min
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
120
Allowed ranges
0–199

Variant 6 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
0
Allowed ranges
0–2

Variant 7 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
1
Allowed ranges
0–2

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.9839.2.1.3.57.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 7 distinct definitions; some records may not include a definition.

Show 7 published definitions

hour_l_comp2 · current

hour_l_comp2 OBJECT-TYPE
                    SYNTAX Integer32 (-32767..32767)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Low part, operating hours compressor 2"
                    ::= { integerObjects 57 }

min_off_time_c2 · current

min_off_time_c2 OBJECT-TYPE
                    SYNTAX Integer32 (0..900)
                    UNITS "sec"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Minimum OFF time"
                    DEFVAL { 60 }
                    ::= { integerObjects 57 }

delay-Freecooling-Thermal-Exclusion · current

delay-Freecooling-Thermal-Exclusion  OBJECT-TYPE
                    	SYNTAX Integer32 (0..999)
                    	UNITS "N/A"
                   		MAX-ACCESS read-write
                   		STATUS current
                    	DESCRIPTION "Delay Freecoolimg Thermal Exclusion"
                   		::= { integerObjects 57 }

fin_rampa_n3v · current

fin_rampa_n3v OBJECT-TYPE
                    SYNTAX Integer32 (0..100)
                    UNITS "%"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Warm 3p valve end ramp"
                    DEFVAL { 100 }
                    ::= { integerObjects 57 }

temp_al_del_ad · current

temp_al_del_ad OBJECT-TYPE
                    SYNTAX Integer32 (0..199)
                    UNITS "min"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Temperature alarm delay"
                    DEFVAL { 120 }
                    ::= { integerObjects 57 }

modello_valvola · current

modello_valvola OBJECT-TYPE
                    SYNTAX Integer32 (0..2)
                    UNITS "N/A"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Valve model"
                    DEFVAL { 0 }
                    ::= { integerObjects 57 }

h7 · current

h7 OBJECT-TYPE
                    SYNTAX Integer32 (0..2)
                    UNITS "N/A"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Small LCD reading selection."
                    DEFVAL { 1 }
                    ::= { integerObjects 57 }

Meaning

Descriptions

7 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Low part, operating hours compressor 2

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 2

Minimum OFF time

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 3

Delay Freecoolimg Thermal Exclusion

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 4

Warm 3p valve end ramp

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 5

Temperature alarm delay

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 6

Valve model

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 7

Small LCD reading selection.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

7 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

hour_l_comp2 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: hour_l_comp2

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "hour_l_comp2",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "32767",
    ".",
    ".",
    "32767",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Low part, operating hours compressor 2\"",
    "::=",
    "{",
    "integerObjects",
    "57",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -32767,
            32767
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Low part, operating hours compressor 2"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 2Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 2

min_off_time_c2 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: min_off_time_c2

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "min_off_time_c2",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "900",
    ")",
    "UNITS",
    [
      "literal",
      "2273656322"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Minimum OFF time\"",
    "DEFVAL",
    "{",
    "60",
    "}",
    "::=",
    "{",
    "integerObjects",
    "57",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            900
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "sec"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Minimum OFF time"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      60
    ]
  ]
}
Records for description 3Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 3

delay-Freecooling-Thermal-Exclusion · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: delay-Freecooling-Thermal-Exclusion

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "delay-Freecooling-Thermal-Exclusion",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "999",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Delay Freecoolimg Thermal Exclusion\"",
    "::=",
    "{",
    "integerObjects",
    "57",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            999
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Delay Freecoolimg Thermal Exclusion"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 4Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 4

fin_rampa_n3v · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: fin_rampa_n3v

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "fin_rampa_n3v",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "100",
    ")",
    "UNITS",
    [
      "literal",
      "222522"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Warm 3p valve end ramp\"",
    "DEFVAL",
    "{",
    "100",
    "}",
    "::=",
    "{",
    "integerObjects",
    "57",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            100
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "%"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Warm 3p valve end ramp"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      100
    ]
  ]
}
Records for description 5Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 5

temp_al_del_ad · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: temp_al_del_ad

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "temp_al_del_ad",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "199",
    ")",
    "UNITS",
    [
      "literal",
      "226d696e22"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Temperature alarm delay\"",
    "DEFVAL",
    "{",
    "120",
    "}",
    "::=",
    "{",
    "integerObjects",
    "57",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            199
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "min"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Temperature alarm delay"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      120
    ]
  ]
}
Records for description 6Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 6

modello_valvola · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: modello_valvola

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "modello_valvola",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "2",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Valve model\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "integerObjects",
    "57",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            2
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Valve model"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 7Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 7

h7 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: h7

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "h7",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "2",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Small LCD reading selection.\"",
    "DEFVAL",
    "{",
    "1",
    "}",
    "::=",
    "{",
    "integerObjects",
    "57",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            2
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Small LCD reading selection."
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      1
    ]
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.9839)

Fiorindo Sebastiano

Siblings (121)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.9839.2.1.3.102 config_out600
1.3.6.1.4.1.9839.2.1.3.103 config_out700
1.3.6.1.4.1.9839.2.1.3.104 config_out800
1.3.6.1.4.1.9839.2.1.3.105 config_out900
1.3.6.1.4.1.9839.2.1.3.106 config_out10, ht_al_thrsh_ah00
1.3.6.1.4.1.9839.2.1.3.107 config_out1100
1.3.6.1.4.1.9839.2.1.3.108 config_out1200
1.3.6.1.4.1.9839.2.1.3.109 config_out1300
1.3.6.1.4.1.9839.2.1.3.110 config_out1400
1.3.6.1.4.1.9839.2.1.3.111 config_out1500
1.3.6.1.4.1.9839.2.1.3.112 config_out1600
1.3.6.1.4.1.9839.2.1.3.113 config_out1700
1.3.6.1.4.1.9839.2.1.3.114 config_out1800
1.3.6.1.4.1.9839.2.1.3.123 current-day, pos_uscita_pid00
1.3.6.1.4.1.9839.2.1.3.124 current-month, posizione_valvola00
1.3.6.1.4.1.9839.2.1.3.125 current-year, pst_superheat00
1.3.6.1.4.1.9839.2.1.3.126 current-hour, dd_s00
1.3.6.1.4.1.9839.2.1.3.127 current-minute, hh_s00
1.3.6.1.4.1.9839.2.1.3.128 mm_s00
1.3.6.1.4.1.9839.2.1.3.150 chiller-mode-operation00
1.3.6.1.4.1.9839.2.1.3.1008 config_out_digit_900