OID reference

cw-hours-l

1.3.6.1.4.1.9839.2.1.3.88

Description

Chilled Water Runtime - This applies to chilled water units only - low

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.9839.2.1.3 (integerObjects)
Node code
88
Node names
  • cw-hours-l
  • mm_8
  • l2
  • config_in10
  • hh_def_sched7
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.9839.2.1.3.88
URN notation
urn:oid:1.3.6.1.4.1.9839.2.1.3.88
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 9839 2 1 3 88}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) integerObjects(3) cw-hours-l(88)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) integerObjects(3) l2(88)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) integerObjects(3) cw-hours-l(88)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) integerObjects(3) l2(88)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) integerObjects(3) cw-hours-l(88)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) integerObjects(3) l2(88)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) integerObjects(3) cw-hours-l(88)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) integerObjects(3) l2(88)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uncdz-MIB(1) integerObjects(3) cw-hours-l(88)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uncdz-MIB(1) integerObjects(3) l2(88)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) mcellaMIB(1) integerObjects(3) cw-hours-l(88)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) mcellaMIB(1) integerObjects(3) l2(88)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) mastercaseMIB(1) integerObjects(3) cw-hours-l(88)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) mastercaseMIB(1) integerObjects(3) l2(88)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) mastercellasplitMIB(1) integerObjects(3) cw-hours-l(88)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) mastercellasplitMIB(1) integerObjects(3) l2(88)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/9839/2/1/3/88
  • /ISO/Identified-Organization/6/1/4/1/9839/2/1/3/88
  • /ISO/3/6/1/4/1/9839/2/1/3/88
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/cw-hours-l
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/mm_8
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/l2
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/config_in10
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/hh_def_sched7
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/integerObjects/cw-hours-l
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/integerObjects/mm_8
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/integerObjects/l2
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/integerObjects/config_in10
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/integerObjects/hh_def_sched7
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/dap4-alMIB/integerObjects/cw-hours-l
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/dap4-alMIB/integerObjects/mm_8
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/dap4-alMIB/integerObjects/l2
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/dap4-alMIB/integerObjects/config_in10
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/dap4-alMIB/integerObjects/hh_def_sched7
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/uacMIB/integerObjects/cw-hours-l
  • Additional combinations skipped.

SNMP properties

Value type
Integer32
Units
N/A, min, hours, hour
Maximum access defined by MIB
read-write, read-only
Status in MIB
current
Default value
0

Definitions may combine these properties differently.

Compare 5 source variants

Variant 1 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-write
Status in MIB
current
Allowed ranges
-32767–32767

Variant 2 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
min
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
0
Allowed ranges
0–59

Variant 3 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-only
Status in MIB
current
Allowed ranges
-32767–32767

Variant 4 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
hours
Maximum access defined by MIB
read-write
Status in MIB
current
Allowed ranges
0–24

Variant 5 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
hour
Maximum access defined by MIB
read-only
Status in MIB
current
Default value
0
Allowed ranges
-32768–32767

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.9839.2.1.3.88.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 5 distinct definitions; some records may not include a definition.

Show 5 published definitions

l2 · current

l2 OBJECT-TYPE
                    SYNTAX Integer32 (-32767..32767)
                    UNITS "N/A"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "pLAN description address"
                    ::= { integerObjects 88 }

mm_8 · current

mm_8 OBJECT-TYPE
                    SYNTAX Integer32 (0..59)
                    UNITS "min"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Minute of the 8th defrost"
                    DEFVAL { 0 }
                    ::= { integerObjects 88 }

config_in10 · current

config_in10 OBJECT-TYPE
                    SYNTAX Integer32 (-32767..32767)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Type of device connected to input 10"
                    ::= { integerObjects 88 }

hh_def_sched7 · current

hh_def_sched7 OBJECT-TYPE
                    SYNTAX Integer32 (0..24)
                    UNITS "hours"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Hour of the 7th defrosting"
                    ::= { integerObjects 88 }

cw-hours-l · current

cw-hours-l OBJECT-TYPE
                    SYNTAX Integer32 (-32768..32767)
                    UNITS "hour"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Chilled Water Runtime - This applies to chilled water units only - low"
                    DEFVAL { 0 }
                    ::= { integerObjects 88 }

Meaning

Descriptions

5 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Chilled Water Runtime - This applies to chilled water units only - low
Original text from OID Repository
cw-hours-l OBJECT-TYPE
SYNTAX Integer32 (-32768..32767)
UNITS "hour"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Chilled Water Runtime - This applies to chilled water units only - low"
DEFVAL { 0 }
Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

OID Repository

View at oid-base.com

Description 2

pLAN description address

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 3

Minute of the 8th defrost

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 4

Type of device connected to input 10

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 5

Hour of the 7th defrosting

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

5 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 2Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 2

l2 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: l2

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "l2",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "32767",
    ".",
    ".",
    "32767",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"pLAN description address\"",
    "::=",
    "{",
    "integerObjects",
    "88",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -32767,
            32767
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "pLAN description address"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 3Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 3

mm_8 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: mm_8

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "mm_8",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "59",
    ")",
    "UNITS",
    [
      "literal",
      "226d696e22"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Minute of the 8th defrost\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "integerObjects",
    "88",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            59
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "min"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Minute of the 8th defrost"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 4Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 4

config_in10 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: config_in10

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "config_in10",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "32767",
    ".",
    ".",
    "32767",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Type of device connected to input 10\"",
    "::=",
    "{",
    "integerObjects",
    "88",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -32767,
            32767
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Type of device connected to input 10"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 5Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 5

hh_def_sched7 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: hh_def_sched7

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "hh_def_sched7",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "24",
    ")",
    "UNITS",
    [
      "literal",
      "22686f75727322"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Hour of the 7th defrosting\"",
    "::=",
    "{",
    "integerObjects",
    "88",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            24
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "hours"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Hour of the 7th defrosting"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 2 sources

Description 1

cw-hours-l · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)2 sources

Status in source: current.

Names: cw-hours-l

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "cw-hours-l",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "32768",
    ".",
    ".",
    "32767",
    ")",
    "UNITS",
    [
      "literal",
      "22686f757222"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Chilled Water Runtime - This applies to chilled water units only - low\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "integerObjects",
    "88",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -32768,
            32767
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "hour"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Chilled Water Runtime - This applies to chilled water units only - low"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.9839)

Fiorindo Sebastiano

Siblings (121)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.9839.2.1.3.102 config_out600
1.3.6.1.4.1.9839.2.1.3.103 config_out700
1.3.6.1.4.1.9839.2.1.3.104 config_out800
1.3.6.1.4.1.9839.2.1.3.105 config_out900
1.3.6.1.4.1.9839.2.1.3.106 config_out10, ht_al_thrsh_ah00
1.3.6.1.4.1.9839.2.1.3.107 config_out1100
1.3.6.1.4.1.9839.2.1.3.108 config_out1200
1.3.6.1.4.1.9839.2.1.3.109 config_out1300
1.3.6.1.4.1.9839.2.1.3.110 config_out1400
1.3.6.1.4.1.9839.2.1.3.111 config_out1500
1.3.6.1.4.1.9839.2.1.3.112 config_out1600
1.3.6.1.4.1.9839.2.1.3.113 config_out1700
1.3.6.1.4.1.9839.2.1.3.114 config_out1800
1.3.6.1.4.1.9839.2.1.3.123 current-day, pos_uscita_pid00
1.3.6.1.4.1.9839.2.1.3.124 current-month, posizione_valvola00
1.3.6.1.4.1.9839.2.1.3.125 current-year, pst_superheat00
1.3.6.1.4.1.9839.2.1.3.126 current-hour, dd_s00
1.3.6.1.4.1.9839.2.1.3.127 current-minute, hh_s00
1.3.6.1.4.1.9839.2.1.3.128 mm_s00
1.3.6.1.4.1.9839.2.1.3.150 chiller-mode-operation00
1.3.6.1.4.1.9839.2.1.3.1008 config_out_digit_900