OID reference

cw-fan-speed

1.3.6.1.4.1.9839.2.1.3.96

Description

Fan speed (% of output) when cold water cooling.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.9839.2.1.3 (integerObjects)
Node code
96
Node names
  • cw-fan-speed
  • config_in18
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.9839.2.1.3.96
URN notation
urn:oid:1.3.6.1.4.1.9839.2.1.3.96
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 9839 2 1 3 96}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) integerObjects(3) cw-fan-speed(96)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) integerObjects(3) cw-fan-speed(96)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) integerObjects(3) cw-fan-speed(96)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) integerObjects(3) cw-fan-speed(96)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uncdz-MIB(1) integerObjects(3) cw-fan-speed(96)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) mcellaMIB(1) integerObjects(3) cw-fan-speed(96)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) mastercaseMIB(1) integerObjects(3) cw-fan-speed(96)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) mastercellasplitMIB(1) integerObjects(3) cw-fan-speed(96)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) wlprobeMIB(1) integerObjects(3) cw-fan-speed(96)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) insgrdMIB(1) integerObjects(3) cw-fan-speed(96)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ariaMIB(1) integerObjects(3) cw-fan-speed(96)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) pluginMIB(1) integerObjects(3) cw-fan-speed(96)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) mioMIB(1) integerObjects(3) cw-fan-speed(96)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) powersplitMIB(1) integerObjects(3) cw-fan-speed(96)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) fcpMIB(1) integerObjects(3) cw-fan-speed(96)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uchillerMIB(1) integerObjects(3) cw-fan-speed(96)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/9839/2/1/3/96
  • /ISO/Identified-Organization/6/1/4/1/9839/2/1/3/96
  • /ISO/3/6/1/4/1/9839/2/1/3/96
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/cw-fan-speed
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/config_in18
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/integerObjects/cw-fan-speed
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/integerObjects/config_in18
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/dap4-alMIB/integerObjects/cw-fan-speed
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/dap4-alMIB/integerObjects/config_in18
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/uacMIB/integerObjects/cw-fan-speed
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/uacMIB/integerObjects/config_in18
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/uncdz-MIB/integerObjects/cw-fan-speed
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/uncdz-MIB/integerObjects/config_in18
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/mcellaMIB/integerObjects/cw-fan-speed
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/mcellaMIB/integerObjects/config_in18
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/cfp_ncpMIB/integerObjects/cw-fan-speed
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/cfp_ncpMIB/integerObjects/config_in18
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/mastercaseMIB/integerObjects/cw-fan-speed
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/mastercaseMIB/integerObjects/config_in18
  • Additional combinations skipped.

SNMP properties

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-only
Status in MIB
current
Default value
85

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-only
Status in MIB
current
Allowed ranges
-32767–32767

Variant 2 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-only
Status in MIB
current
Default value
85
Allowed ranges
60–100

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.9839.2.1.3.96.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

config_in18 · current

config_in18 OBJECT-TYPE
                    SYNTAX Integer32 (-32767..32767)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Type of device connected to input 18"
                    ::= { integerObjects 96 }

cw-fan-speed · current

cw-fan-speed OBJECT-TYPE
                    SYNTAX Integer32 (60..100)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Fan speed (% of output) when cold water cooling."
                    DEFVAL { 85 }
                    ::= { integerObjects 96 }

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Fan speed (% of output) when cold water cooling.
Original text from OID Repository
cw-fan-speed OBJECT-TYPE
SYNTAX Integer32 (60..100)
UNITS "N/A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Fan speed (% of output) when cold water cooling."
DEFVAL { 85 }
Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

OID Repository

View at oid-base.com

Description 2

Type of device connected to input 18

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

2 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 2Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 2

config_in18 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: config_in18

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "config_in18",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "32767",
    ".",
    ".",
    "32767",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Type of device connected to input 18\"",
    "::=",
    "{",
    "integerObjects",
    "96",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -32767,
            32767
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Type of device connected to input 18"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 2 sources

Description 1

cw-fan-speed · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)2 sources

Status in source: current.

Names: cw-fan-speed

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "cw-fan-speed",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "60",
    ".",
    ".",
    "100",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Fan speed (% of output) when cold water cooling.\"",
    "DEFVAL",
    "{",
    "85",
    "}",
    "::=",
    "{",
    "integerObjects",
    "96",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            60,
            100
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Fan speed (% of output) when cold water cooling."
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      85
    ]
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.9839)

Fiorindo Sebastiano

Siblings (121)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.9839.2.1.3.102 config_out600
1.3.6.1.4.1.9839.2.1.3.103 config_out700
1.3.6.1.4.1.9839.2.1.3.104 config_out800
1.3.6.1.4.1.9839.2.1.3.105 config_out900
1.3.6.1.4.1.9839.2.1.3.106 config_out10, ht_al_thrsh_ah00
1.3.6.1.4.1.9839.2.1.3.107 config_out1100
1.3.6.1.4.1.9839.2.1.3.108 config_out1200
1.3.6.1.4.1.9839.2.1.3.109 config_out1300
1.3.6.1.4.1.9839.2.1.3.110 config_out1400
1.3.6.1.4.1.9839.2.1.3.111 config_out1500
1.3.6.1.4.1.9839.2.1.3.112 config_out1600
1.3.6.1.4.1.9839.2.1.3.113 config_out1700
1.3.6.1.4.1.9839.2.1.3.114 config_out1800
1.3.6.1.4.1.9839.2.1.3.123 current-day, pos_uscita_pid00
1.3.6.1.4.1.9839.2.1.3.124 current-month, posizione_valvola00
1.3.6.1.4.1.9839.2.1.3.125 current-year, pst_superheat00
1.3.6.1.4.1.9839.2.1.3.126 current-hour, dd_s00
1.3.6.1.4.1.9839.2.1.3.127 current-minute, hh_s00
1.3.6.1.4.1.9839.2.1.3.128 mm_s00
1.3.6.1.4.1.9839.2.1.3.150 chiller-mode-operation00