Objects in INTERFACES-MIB

OID records

OIDNameDescription
1.3.6.1.4.1.425.8.3.2.1.43t1e1AlarmResetThis is used to clear the current alarm counts.
1.3.6.1.4.1.425.8.3.2.1.5t1e1AlarmSummaryThis object provides a summary of the port alarms.
1.3.6.1.4.1.425.8.3.2.1.6t1e1ESStatusReports if a Errorred Seconds condition exists.
1.3.6.1.4.1.425.8.3.2.1.8t1e1ESThresholdSets the Errored Seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
1.3.6.1.4.1.425.8.3.2.1.9t1e1ESAlarmThis status indicates if the Errors Seconds threshold is exceeded.
1.3.6.1.4.1.425.8.11.1.1.2traplogNearIndexSpecifies the near device.
1.3.6.1.4.1.425.8.4.1.1ddsNetConfigTableEntryAn entry in the Network Interface Table.
1.3.6.1.4.1.425.8.4.1.1.1ddsNetConfigNearIndexSelects the near device.
1.3.6.1.4.1.425.8.4.1.1.10ddsNetAntiStrTimerThis variable describes the current setting for the
anti streaming timer. The values mean:
ddsNetAntiStrTimerOff
the AntiStreaming Timer is off
ddsNetAntiStrTimer1…
1.3.6.1.4.1.425.8.4.1.1.2ddsNetConfigFarIndexSelects the far device.
1.3.6.1.4.1.425.8.4.1.1.3ddsNetConfigIndexIndex into the ddsNetConfigTable.
1.3.6.1.4.1.425.8.4.1.1.4ddsNetDescriptionContains a textual description of the port.
1.3.6.1.4.1.425.8.4.1.1.5ddsNetRateThis object is the identifier of the current DDS network rate. The values mean:
ddsNetRate2400
the DDS network interface is operating at
2400bps
ddsNetRate4800
the …
1.3.6.1.4.1.425.8.4.1.1.6ddsNetModeThis variable describes mode in which data is
being sent from the DDS unit back towards the
network. Changing the value of this variable can
cause a loss of remot…
1.3.6.1.4.1.425.8.4.1.1.7ddsNetTimingSourceThis variable describes the current timing source for
the DDS network interface. The values mean:
ddsNetTimingNet
unit dependant upon network for DDS network
inter…
1.3.6.1.4.1.425.8.4.1.1.8ddsNetRemCommThis variable describes the current setting for the
remote communications link. The values mean:
ddsNetRemCommEnabled
remote communications can be carried out end
…
1.3.6.1.4.1.425.8.4.1.1.9ddsNetCircuitAssurThis variable describes the current setting for the
circuit assurance option. The values mean:
ddsNetCircuitAssurEnabled
Circuit Assurance is enabled and the
integ…
1.3.6.1.4.1.425.8.3.1.1.15t1e1KeepAliveSelects keep alive framed and unframed ones when the unit detects LOS or OOF.
1.3.6.1.4.1.425.8.10.1.1.3iTableIndexThe index into the interface table, used for addressing in above tables.
1.3.6.1.4.1.425.8.7connection
1.3.6.1.4.1.425.8.7.1connectionTableThe connection table.
1.3.6.1.4.1.425.8.7.2connectionChannelTableThe channel-level connection table.
1.3.6.1.4.1.425.8.5.2.1.2serialDteAlarmFarIndexSelects the far device.
1.3.6.1.4.1.425.8.2.1dbuConfigTableThe Dial Backup Configuration Table.
1.3.6.1.4.1.425.8.2dbu
1.3.6.1.4.1.425.3temporary
1.3.6.1.4.1.425txportTxPort
1.3.6.1.4.1.425.8.8.3.1.5testLoopDirectionThis object is the identifier of the current unit loop mode. The values mean:
testLoopUnidirectional
Line, Data, and V54 loops will be unidirectional
Local loop w…
1.3.6.1.4.1.425.8.8.3.1testTableEntryAn entry in the testTable.
1.3.6.1.4.1.425.8.4.2.1.22ddsNetAlarmResetTimerSets the Alarm Reset Timer, this field can be set to any value in the range 0 to 900.
1.3.6.1.4.1.425.8.9.1.1.5performance24ESThe number of Errored Seconds for the 15-minute period.
1.3.6.1.4.1.425.8.8.3testTableTest control table.
1.3.6.1.4.1.425.8.8maintenance
1.3.6.1.4.1.425.8.5.1.1.21serialDteStartChannelSpecifies the starting channel for the interface.
1.3.6.1.4.1.425.8.9.1.1.2performance24FarIndexSelects the far device.
1.3.6.1.4.1.425.8.5.1.1.24serialDteBundleSpecifies the allocation pattern of channels assigned
to the serial port.
1.3.6.1.4.1.425.8.9.2.1.12performance30OOFSThe number of Out of Frame Seconds for the 1-day period.
1.3.6.1.4.1.425.8.7.2.1.3connectionChannelLineIndexSelects instance of line.
1.3.6.1.4.1.425.8.7.2.1connectionChannelEntryAn entry in the connectionChannelTable.
1.3.6.1.4.1.425.8.4.2.1.8ddsNetLOSThresholdA period, measured in seconds, in which the DDS received signal is interrupted.
1.3.6.1.4.1.425.8.2.1.1.12dbuActivator2This object is the identifier of the current
trigger that will activate the Dial Backup
Unit. The values mean:
dbuActivatorLOS
The dial backup unit is activated by…
1.3.6.1.4.1.425.8.5.1.1.19serialDteLLSpecifies if the unit should respond to local loop activation by the local loopback signal (EIA530 or RS-232 pin 18).
1.3.6.1.4.1.425.8.5.1.1.17serialDteCTSSpecifies the control of the CTS signal at the port.
1.3.6.1.4.1.425.8.2.1.1.7dbuFormatThis object is the identifier of the current
format that the Dial Backup Unit is operating
in. The values mean:
dbuFormatSync
The dial backup unit is operating in …
1.3.6.1.4.1.425.8.5.1.1.9serialDteParityThis variable describes the current parity selected
for the DTE interface. This variable is only valid
when the DTE Mode is set to ASYNC. The values mean:
serialD…
1.3.6.1.4.1.425.8.1.1.1.10mgmtPortsInternalModemThis object signifies if the internal modem (when present) is enabled.
1.3.6.1.4.1.425.8.1.1.1mgmtPortsTableEntryAn entry in the Management Ports table.
1.3.6.1.4.1.425.8.8.3.1.1testNearIndexSelects the near device.
1.3.6.1.4.1.425.8.7.2.1.6channelInterfaceDescriptionContains a description of the interface channel connection.
1.3.6.1.4.1.425.8.3.1.1.3t1e1ConfigIndexThis object is the index into the t1e1Table.