Objects in TIMETRA-CHASSIS-MIB

OID records

OIDNameDescription
1.3.6.1.4.1.6527.3.1.1.2.1.1tmnxChassisCompliances
1.3.6.1.4.1.6527.3.1.2.2.3.4.1.19tmnxCpmCardSwitchToRedundantCardSetting this variable to doAction causes the switchover to the
redundant CPM card.
1.3.6.1.4.1.6527.3.1.2.2.1.5.1.10tmnxChassisPowerSupplyOutputStatusIf the value of tmnxChassisPowerSupplyOutputStatus is 'deviceStateOk',
the output voltage of the power supply is within range. If the value
is 'deviceStateFaile…
1.3.6.1.4.1.6527.3.1.2.2.3.14.1.8tmnxCcagPathCcCollectStatsThe value of tmnxCcagPathCcCollectStats specifies whether the collection
of accounting and statistical data for the network port is
enabled/disabled, 'true'/'fal…
1.3.6.1.4.1.6527.3.1.2.2.1.3.1.7tmnxChassisNumSlotsThe number of slots in this chassis that are available for plug-in
cards. This includes both fabric and IOM cards
1.3.6.1.4.1.6527.3.1.2.2.3.4.1.1tmnxCpmCardSlotNumThe unique value which identifies this slot within a chassis in
the system. Depending upon the value of tmnxChassisType, this may
represent a fabric slot or a r…
1.3.6.1.4.1.6527.3.1.2.2.3.8.1.29tmnxMDAMcPathMgmtSecPathLimitThe value of tmnxMDAMcPathMgmtSecPathLimit specifies the secondary path
limit for the MDA.
1.3.6.1.4.1.6527.3.1.2.2.3.11.1.12tmnxSyncIfTimingRef2QualifiedThe value of tmnxSyncIfTimingRef2Qualified indicates whether the
second timing reference is qualified for use by the synchronous
timing subsystem. If tmnxSyncIf…
1.3.6.1.4.1.6527.3.1.1.2.1.2.11tmnxChassisObsoleteGroupThe group of objects supporting the allowed types of CPM cards, IOM
cards and MDA made obsolete for revision 3.0 on Alcatel 7x50 SR series
systems.
1.3.6.1.4.1.6527.3.1.2.2.3.9.1.2tmnxCardTypeNameThe administrative name that identifies this type of Alcatel
7x50 SR series card model. This name string may be used in
CLI commands to specify a particular car…
1.3.6.1.4.1.6527.3.1.2.2.3.11.1.14tmnxSyncIfTimingFreqOffsetThe value of tmnxSyncIfTimingFreqOffset indicates the frequency offset
of the current selected timing reference in parts per million (ppm).
1.3.6.1.4.1.6527.3.1.2.2.1.8.1.9tmnxHwAliasThe value of tmnxHwAlias is the administrative name assigned to this
hardware component by the CLI user or network manager. It is saved
across re-initialization…
1.3.6.1.4.1.6527.3.1.2.2.1.5.1.5tmnxChassisPowerSupplyTempThresholdThe temperature threshold for this power supply tray in degrees
celsius. When the temperature raises above
tmnxChassisPowerSupplyTempThreshold, a 'temperature t…
1.3.6.1.4.1.6527.3.1.2.2.3.11.1.3tmnxSyncIfTimingRefOrder2The value of tmnxSyncIfTimingRefOrder2 indicates the second most
preferred timing reference for the synchronous equipment timing
subsystem.
1.3.6.1.4.1.6527.3.1.2.2.1.3.1.6tmnxChassisCoordinatesA user supplied string that indicates the Global Positioning System (GPS) coordinates for the location of this chassis. N 45 58 23, W 34 56 12 N37 37' 00 latit…
1.3.6.1.4.1.6527.3.1.2.2.3.8.1.13tmnxMDACapabilitiestmnxMDACapabilities indicates the capabilities of this MDA.
It identifies the type of MDA and the protocols that can run on it.
1.3.6.1.4.1.6527.3.1.2.2.3.4.1.13tmnxCpmCardConfigLastSavedThe date and time the current configuration was last saved.
If tmnxCpmCardConfigLastSaved is more recent the value of
tmnxHwSwLastBoot, the initial configuration…
1.3.6.1.4.1.6527.3.1.2.2.1.4.1.3tmnxChassisFanSpeedThe value of tmnxChassisFanSpeed indicates if the fans in this
fan tray are running at 'halfSpeed' or 'fullSpeed'.
1.3.6.1.4.1.6527.3.1.2.2.1.10.1tmnxCcmEntryContains information regarding a CCM.
1.3.6.1.4.1.6527.3.1.2.2.1.1tmnxChassisTotalNumberThe number of chassis installed in this system. For the first
release of the Alcatel 7x50 series product, there is only
1 chassis per system. A multi-chassis s…
1.3.6.1.4.1.6527.3.1.2.2.1.8.1.16tmnxHwOperStateThe actual operational status of this hardware component.

unknown (1) Status cannot be determined

inService (2) Online - If tmnxHwCla…
1.3.6.1.4.1.6527.3.1.2.2.1.10.1.1tmnxCcmIndexThe unique value which identifies a specific CCM instance in the
chassis.
1.3.6.1.4.1.6527.3.1.2.2.1.5.1.7tmnxChassisPowerSupply2StatusThe overall status of an equipped power supply. For AC multiple power
supplies, this represents the overall status of the second power supply
in the tray (or she…
1.3.6.1.4.1.6527.3.1.2.2.3.11.1.16tmnxSyncIfTimingRefOrder3The value of tmnxSyncIfTimingRefOrder3 is the third most preferred
timing reference for the synchronous equipment timing subsystem.
1.3.6.1.4.1.6527.3.1.2.2.6.9tmnxChassisNotifySoftwareLocationUsed by tmnxPeSoftwareLoadFailed, the value of
tmnxChassisNotifySoftwareLocation contains the location of the
software.
1.3.6.1.4.1.6527.3.1.2.2.1.4.1.1tmnxChassisFanIndexThe unique value which identifies a specific fan tray in the
chassis.
1.3.6.1.4.1.6527.3.1.2.2.1.6.1.1tmnxChassisTypeIndexThe unique index value which identifies this type of Alcatel
7x50 SR series chassis model.
1.3.6.1.4.1.6527.3.1.2.2.1.5.1.3tmnxChassisPowerSupplyDCStatusIf the value of tmnxChassisPowerSupplyDCStatus is 'deviceStateOk',
the input DC voltage is within range. If the value is
'deviceStateFailed', an DC voltage out …
1.3.6.1.4.1.6527.3.1.1.2.1.2.4tmnxChassisNotifyObjsGroupThe group of objects supporting chassis hardware notifications
on Alcatel 7x50 SR series systems.
1.3.6.1.4.1.6527.3.1.2.2.1.8.1.29tmnxHwBaseMacAddresstmnxHwBaseMacAddress contains the base MAC address of the hardware
component. It is applicable only if tmnxHwClass is of type 'chassis',
'ioModule', 'cpmModule' …
1.3.6.1.4.1.6527.3.1.2.2.3.7.1.3tmnxCpmFlashSerialNumberThe serial number for this flash unit on this CPM card.
1.3.6.1.4.1.6527.3.1.3.2.1.0.13tmnxEqBackdoorBusFailureGenerated when the backdoor bus has failed.

This notification was made obsolete in the 2.1 release.
1.3.6.1.4.1.6527.3.1.2.2.1.3.1.22tmnxChassisUpdateWaitTimeThe value of tmnxChassisUpdateWaitTime specifies the time to wait
before rebooting IOM cards running older software versions following
a software upgrade or down…
1.3.6.1.4.1.6527.3.1.3.2.1.0.11tmnxEqCpuFailureGenerated when a failure is detected for a CPU on an IOM card or
CPM module.

This notification was made obsolete in the 2.1 release.

A cpu failure on a CPM card …
1.3.6.1.4.1.6527.3.1.2.2.1.4.1tmnxChassisFanEntryContains information regarding a fan tray.
1.3.6.1.4.1.6527.3.1.2.2.3.8.1.10tmnxMDATxTimingSelectedThe transmit timing method which is presently selected and being
used by this MDA.
tmnxMDATxTimingSelected will be set to 'not-applicable' if this MDA
does not us…
1.3.6.1.4.1.6527.3.1.2.2.3.11.1.1tmnxSyncIfTimingRevertThe value of tmnxSyncIfTimingRevert indicates whether the reference
source will revert to a higher priority source that has been
re-validated or newly validated.
…
1.3.6.1.4.1.6527.3.1.2.2.3.15.1.3tmnxMcmAssignedTypeA bit-mask that identifies the administratively assigned
(pre-provisioned) MCM type that should occupy this chassis.
If tmnxMcmAssignedType has a value of 'unass…
1.3.6.1.4.1.6527.3.1.1.2.1.1.5.3tmnxChassisComp7710V6v0The compliance statement for management of chassis features
for the 7710 in the TIMETRA-CHASSIS-MIB.
1.3.6.1.4.1.6527.3.1.2.2.3.13tmnxCcagPathTableThe tmnxCcagPathTable has an entry for each Cross Connect
Aggregation Group, CCAG, path configured on this system.
1.3.6.1.4.1.6527.3.1.2.2.3.2.1.16tmnxCardNamedPoolOperModeThe value of tmnxCardNamedPoolOperMode specifies whether or
not an IOM provisioned with tmnxCardNamedPoolAdminMode to a
value of 'inService(2)' will activly use …
1.3.6.1.4.1.6527.3.1.2.2.3.7.1.4tmnxCpmFlashFirmwareRevisionThe firmware revision number for this flash unit on this CPM card.
1.3.6.1.4.1.6527.3.1.2.2.3.11.1.6tmnxSyncIfTimingRef1InUseThe value of tmnxSyncIfTimingRef1InUse indicates whether the first
timing reference is presently being used by the synchronous timing
subsystem. If it is in use…
1.3.6.1.4.1.6527.3.1.2.2.6.10tmnxChassisNotifyCardFailureReasonUsed by tmnxEqCardFailure, the value of
tmnxChassisNotifyCardFailureReason contains the
reason for card failure.
1.3.6.1.4.1.6527.3.1.2.2.3.12.1.8tmnxCcagAccessAdaptQosThe value of tmnxCcagAccessAdaptQos specifies how the CCAG SAP queue
and virtual scheduler buffering and rate parameters are adapted over
multiple active CCAs.
li…
1.3.6.1.4.1.6527.3.1.2.2.3.12.1.6tmnxCcagOperStatusThe value of tmnxCcagOperStatus indicates the operational state of this
CCAG.
1.3.6.1.4.1.6527.3.1.3.2.1.0.40tmnxEqCardFirmwareUpgradedGenerated when a card is hot-inserted into the chassis and its
firmware is automatically upgraded. The card type may be IOM or
CPM module.
1.3.6.1.4.1.6527.3.1.2.2.8.1.4tmnxChassisAdminLastSetTimeoutTimeout for tmnxChassisAdminLastSetTimer.
The value zero is not allowed.
1.3.6.1.4.1.6527.3.1.2.2.1.8.1.20tmnxHwBootCodeVersionThe version number of boot eprom on the card in this slot.

If no specific software program is associated with this hardware
component then this object will cont…
1.3.6.1.4.1.6527.3.1.1.2.1.2tmnxChassisGroups