The value of tmnxCardNamedPoolOperMode specifies whether or
not an IOM provisioned with tmnxCardNamedPoolAdminMode to a
value of 'inService(2)' will activly use named pools or not.
A value of 'outOfService(3) means that the named pool configurations
will not be downloaded to the IOM until after a reset of the IOM
is performed. A value of 'inService(2)' means that the named pool
configurations are programmed by the IOM. On systems using a
separate CPM and IOM combination the value of tmnxCardNamedPoolOperMode
and tmnxCardNamedPoolAdminMode will always be in sync due to a
mandatory reboot of the IOM. On systems using a combined image (CFM)
these values will be out-of-sync until the chassis is rebooted.
Parsed from file TIMETRA-CHASSIS-MIB.mib
Module: TIMETRA-CHASSIS-MIB
tmnxCardNamedPoolOperMode OBJECT-TYPE SYNTAX TmnxAdminState MAX-ACCESS read-only STATUS current DESCRIPTION "The value of tmnxCardNamedPoolOperMode specifies whether or not an IOM provisioned with tmnxCardNamedPoolAdminMode to a value of 'inService(2)' will activly use named pools or not. A value of 'outOfService(3) means that the named pool configurations will not be downloaded to the IOM until after a reset of the IOM is performed. A value of 'inService(2)' means that the named pool configurations are programmed by the IOM. On systems using a separate CPM and IOM combination the value of tmnxCardNamedPoolOperMode and tmnxCardNamedPoolAdminMode will always be in sync due to a mandatory reboot of the IOM. On systems using a combined image (CFM) these values will be out-of-sync until the chassis is rebooted." DEFVAL { outOfService } ::= { tmnxCardEntry 16 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.6527.3.1.2.2.3.2.1.1 | tmnxCardSlotNum | 0 | 0 | The unique value which identifies this IOM slot within a chassis in the system. |
1.3.6.1.4.1.6527.3.1.2.2.3.2.1.2 | tmnxCardSupportedTypes | 0 | 0 | A bit-mask that specifies what card types can be physically supported in this IOM slot in this chassis. |
1.3.6.1.4.1.6527.3.1.2.2.3.2.1.3 | tmnxCardAllowedTypes | 0 | 0 | A bit-mask that specifies what IOM card types the administrator has designated be allowed to be inserted into this slot. If the s… |
1.3.6.1.4.1.6527.3.1.2.2.3.2.1.4 | tmnxCardAssignedType | 0 | 0 | A bit-mask that identifies the administratively assigned (pre-provisioned) IOM card type that should occupy this slot in this cha… |
1.3.6.1.4.1.6527.3.1.2.2.3.2.1.5 | tmnxCardEquippedType | 0 | 0 | A bit-mask that identifies the IOM card type that is physically inserted into this slot in this chassis. If the slot has been pr… |
1.3.6.1.4.1.6527.3.1.2.2.3.2.1.6 | tmnxCardHwIndex | 0 | 0 | The value of tmnxCardHwIndex is the index into the tmnxHwTable for the row entry that represents the hardware component informat… |
1.3.6.1.4.1.6527.3.1.2.2.3.2.1.10 | tmnxCardClockSource | 0 | 0 | The clock source used by the IOM card in this slot. |
1.3.6.1.4.1.6527.3.1.2.2.3.2.1.11 | tmnxCardNumMdaSlots | 0 | 0 | The number of Media Dependent Adapter (MDA) slots available on this IOM card. |
1.3.6.1.4.1.6527.3.1.2.2.3.2.1.12 | tmnxCardNumMdas | 0 | 0 | The number of Media Dependent Adapters installed on this IOM card. |
1.3.6.1.4.1.6527.3.1.2.2.3.2.1.13 | tmnxCardReboot | 0 | 0 | Setting this variable to 'doAction' causes the IOM card to execute a soft-reboot. |
1.3.6.1.4.1.6527.3.1.2.2.3.2.1.14 | tmnxCardMemorySize | 0 | 0 | The value of tmnxCardMemorySize indicates the amount of memory, in mega-bytes, populated on this IOM card. |
1.3.6.1.4.1.6527.3.1.2.2.3.2.1.15 | tmnxCardNamedPoolAdminMode | 0 | 0 | The value of tmnxCardNamedPoolAdminMode specifies whether or not an IOM is provisioned for the configuration of named pools. If t… |